background image

 

 

 

 

 

DIAMOND VIEW

 

®

 DV151 

 

Colour LCD Monitor

 

15.1” (38.4 cm) LCD Panel Size 

Summary of Contents for DV151

Page 1: ...DIAMOND VIEW DV151 Colour LCD Monitor 15 1 38 4 cm LCD Panel Size ...

Page 2: ...MODV151UG 0900 1 ...

Page 3: ...llennium Edition Windows Me 9 Windows 2000 9 6 Setting the Display Resolution 10 Choosing The Best Resolution 10 Supported Graphics Modes and Refresh Rate Selection 11 7 Adjusting the Monitor 13 Picture Optimisation 13 Manual Picture Adjustment 13 8 Security Lock Installation 16 9 Frequently Asked Questions 17 10 Specifications 19 11 Service Contacts 21 Australian Service Contacts 21 New Zealand S...

Page 4: ...fitness for any particular purpose Further Mitsubishi Electric Australia reserves the right to revise this publication and to make changes from time to time in the contents hereof without obligation to notify any person of such revision or changes Diamond View is a registered trademark of Mitsubishi Electric Australia Pty Ltd Microsoft and Windows are registered trademarks of Microsoft Corporation...

Page 5: ...red This product should never be placed near or over a radiator or other heat source or in a built in installation unless proper ventilation is provided 3 Never push objects of any kind or spill liquid of any kind into this product 4 Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous voltages or other risks 5 If any abnormal operation or accid...

Page 6: ...standard When the system is idle in monitor off mode the monitor automatically cuts its power consumption to less than 5 W On Screen Display Allows you to adjust all settings simply using on screen menus High Quality Ratiometric Expansion With any resolution within the monitor s specified range your Diamond View DV151 monitor can expand the image to full screen True Colour Display With dithering s...

Page 7: ...r place of purchase immediately LCD monitor with attached signal cable Power cord User s manual Audio Cable Utilities and Driver Floppy Diskette Locate the model name and the serial number label on the back of your monitor and write the details of the monitor and your place of purchase in the space on page ii of this manual for future reference ...

Page 8: ...ity supplier To install your Diamond View DV151 monitor 1 Make sure that the power to the computer and the power to the monitor are both turned off 2 Connect the blue connector of the monitor s VGA cable to the VGA output of the computer s graphics card 3 Connect the monitor s power cord to an AC power socket Please make sure that you have easy access to the power socket so you can disconnect the ...

Page 9: ...llation 1 Remove the rear cover and then take the base cover off 2 Connect the stereo audio cable from the Audio output of your sound card to the Audio Input of the monitor 3 Replace the base cover and the rear cover 7 ...

Page 10: ...om right corner 4 Select the Monitor tab and then click the Change button 5 Click the Have Disk button at the bottom right corner The Install From Disk window will appear with the floppy drive A selected Click OK 6 Select DV151 from the list and click OK again to install the driver 7 You will be returned to the Advanced Graphics Properties dialogue Close this window by clicking OK and confirm the ...

Page 11: ...ctions beginning at step 7 Otherwise to install the monitor driver and ICC colour profile 1 Click Start and then Settings and open the Control Panel 2 Double click the Display icon 3 From the Display Properties dialogue box select the Settings tab Click the Advanced button at the bottom right corner 4 Select Monitor then click Properties 5 Select the Driver tab and click Update Driver 6 The Upgrad...

Page 12: ...rties dialogue box select the Settings tab There is a slider on the right hand side in the middle of the dialogue that alters the displayed resolution Set the resolution to 1024x768 3 For Windows NT users only select a refresh rate of either 60 Hz or 75 Hz and click Test A test pattern will be displayed Make sure that there are no error messages shown by the monitor If an error message is displaye...

Page 13: ...he control panel 2 From the Display Properties dialogue select the Settings tab and click the Advanced Properties button 3 Select the Adapter tab The refresh rate selection field is located in the centre at the bottom of the dialogue box 4 Choose a refresh rate that corresponds with one of the factory modes from the table below 5 Click Apply and then OK twice Please Note Graphics modes that are no...

Page 14: ...onitor off after extended idle periods Input Signal Multi scan mode Resolution Horizontal Frequency kHz Vertical Frequency Hz Pixel Frequency MHz Comment Actual Display Resolution 640x 350 31 47 P 70 08 N 25 17 DOS 1024x675 720x 400 31 47 N 70 08 P 28 32 DOS 640x 480 31 47 N 60 00 N 25 18 DOS 640x 480 37 86 N 72 80 N 31 50 VESA 640x 480 37 50 N 75 00 N 31 50 VESA 800x 600 35 16 P 56 25 P 36 00 VES...

Page 15: ...ormats are also available from the File Downloads section of Mitsubishi Electric Australia s web site at www mitsubishi electric com au Follow the link to the TFT LCD monitors page and download a pattern with the resolution that you need Display the test pattern at its actual size 100 zoom preferably at full screen and then press the monitor s Auto button If you are still not satisfied with the re...

Page 16: ... users should run the Auto exe test pattern program For non Windows operating systems you also can use the test pattern described in the previous section or another full screen image such the desktop of the operating system 2 Open the OSD menu by pressing the Enter button on the monitor 3 Turn the wheel to select the Geometry submenu and then press Enter 4 Five patterns will be shown at the top of...

Page 17: ...urns blue If you are still not satisfied with the result try repeating the procedure using a graphics signal that has a different refresh rate Notes You must use one of the factory modes If the AUTO button is not working or the NON PRESET MODE message is shown on the OSD you are not using one of the supported modes If you are having difficulties generating a supported mode ask your computer dealer...

Page 18: ...sington lock s cable can be attached to a slot located at the rear of the monitor 1 Insert the lock in the slot located on the rear of the monitor 2 Turn the key to lock the Security Lock 3 Remove the key and store it in a safe place Note Kensington locks are not available from Mitsubishi Electric Australia Please contact your reseller for more information ...

Page 19: ...uction losses of the extension cable You can minimise these losses by using an extension cable with better conduction quality or with a built in booster Does the blurring only occur at resolutions lower than the native maximum resolution Please read chapter 6 Setting the Display Resolution Select a graphics signal that uses the monitor s the native resolution 1024 x 768 pixels Why does the image l...

Page 20: ...GA cable s connector If any pins are bent or broken off then contact your dealer see Chapter 11 for details If the LED is not lit at all check that the monitor is plugged into the power supply mains socket and that the power switch is turned on Check that the monitor s power switch is also turned on The image is or distorted flashes or flickers Check that the monitor s signal cable is securely con...

Page 21: ...sponse Time 40 ms maximum Viewing Angle Left Right Up Down 60 60 45 55 typical Dot Pitch 0 3 mm User Interface Controls Mains power switch 2 buttons and rotary wheel to control On Screen Display Automatic image adjustment On Screen Display Functions Contrast Brightness Vert Hor Image Position Phase Pixel Clock Color Balance Color Palette Choice of language 6 language OSD OSD Position Status Indica...

Page 22: ...hysical Characteristics Power Management VESA DPMS Energy Star Maximum Power Consumption 36 Watts Power Saving Mode 5 Watts Operating Voltage Automatic switched mode power supply 90 264 V 47 63 Hz Dimensions W x H x D 380 x 383 x 186 mm Weight 5 5 kg Temperature Operating 5 C 40 C Air Humidity Operating 20 85 Regulatory Certification Safety IEC 950 EN 60950 TÜV GS AS NZS 3260 UL1950 PTB EMI EMC CS...

Page 23: ...ils of your nearest Mitsubishi Electric Authorised Service Centre or contact the Service Department for your state New South Wales and Australian Capital Territory 348 Victoria Road Rydalmere NSW 2116 Telephone 02 9684 7669 Fax 02 9684 7684 Queensland 1 104 Newmarket Road Windsor Qld 4030 Telephone 07 3357 8877 Fax 07 3357 8488 South Australia and Northern Territory 77 Port Road Hindmarsh SA 5007 ...

Page 24: ... 9899 Fax 03 9262 9850 Western Australia 5 329 Collier Road Bassendean WA 6054 Telephone 08 9377 3411 Fax 08 9377 3499 New Zealand Service Contacts Contact Melco New Zealand Ltd 1 Parliament St Lower Hutt Wellington Telephone 04 560 9100 Fax 04 560 9140 Web site www melco co nz 22 ...