background image

 

 

Manual

 

Page 1 of 19

 

 

© DEUTA Controls GmbH

 

Paffrather Str. 140, 51465 Bergisch Gladbach

 

Tel.:+49 2202 285 57- 61 

06.07.2021 

Hauptstraße 76, 32479 Hille 

  

 

Tel: +49 5734 51466 - 0 

Technical data might change 

 

[email protected]

;  

www.deuta-controls.net

 

Fax:+49 5734 51466 - 28 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AL-602-03-902 EnoPuck BASIC 

 

Desk Sensor with vibration and PIR sensor 
EnOcean 902 MHz  

 

Part no. 12408 
 

 

Version 1.1.02, valid since FW/HW 1.0 / 2.0 

 

 

Summary of Contents for 12408

Page 1: ... 57 61 06 07 2021 Hauptstraße 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls net Fax 49 5734 51466 28 AL 602 03 902 EnoPuck BASIC Desk Sensor with vibration and PIR sensor EnOcean 902 MHz Part no 12408 Version 1 1 02 valid since FW HW 1 0 2 0 ...

Page 2: ...sions is prohibited Reproduction translation electronic and phototechnical filing archiving e g photocopying as well as any amendments require the written consent of DEUTA Controls GmbH Bergisch Gladbach Germany Non observance will involve the right to assert damage claims DEUTA Controls GmbH Paffrather Straße 140 51465 Bergisch Gladbach Phone 49 2202 28557 61 Fax 49 2202 28557 79 E Mail info deut...

Page 3: ...4 4 Observe statutory provisions for operating frequency range 7 4 5 Non conduction mounting surface 7 5 Technical data 8 5 1 Communication EnOcean wireless interface 8 5 2 Sensor Vibration sensor 8 5 3 Sensor Motion PIR 8 5 4 User interfaces 8 5 5 Housing connection technology 8 5 6 Power supply 9 5 7 Environmental conditions 9 5 8 Dimensions and weight 9 5 9 Approvals 9 5 10 Standards and guidel...

Page 4: ...6 07 2021 Hauptstraße 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 8 Safety remarks 14 9 Device labels 15 10 FCC United States Regulatory Statement 16 11 ISED Regulatory Statement 16 12 Dimensions drawings 17 13 Ordering information 18 14 Revision history 19 ...

Page 5: ...nd operated according to the instructions in these operating instructions 2 Intended use The AL 602 03 902 EnoPuck BASIC must not be used in any relation with equipment that supports directly or indirectly human health or life or with applications that can result in danger for people animals or real value The AL 602 03 902 EnoPuck BASIC can be put on a tables surface or even mounted below a desk u...

Page 6: ... by the internal vibration and PIR passive infrared motion sensor in the front The integrated radio interface based on EnOcean wireless technology offers the possibility to integrate this information into any building automation system with an EnOcean interface It can also be directly teached in into an EnOcean based actuator If vibration or motion is detected a wireless message will be sent by th...

Page 7: ...elation with equipment that supports directly or indirectly human health or life or with applications that can result in danger for people animals or real value 4 4 Observe statutory provisions for operating frequency range The AL 602 03 902 EnoPuck BASIC must only be operated in compliance with the country specific provisions regarding operation of radio equipment 4 5 Non conduction mounting surf...

Page 8: ...pe EnOcean Number 1 Transmit receive center frequency 902 875 MHz Maximum transmission power 99 dBµV m Table 1 Technical data communication 5 2 Sensor Vibration sensor Measuring range 8 g Sensitivity 0 05 g Table 2 Technical data vibration sensor 5 3 Sensor Motion PIR Detection angle 100 degrees Detection range 3 5 m Table 3 Technical data PIR sensor 5 4 User interfaces Service button Yes Service ...

Page 9: ...data power supply 5 7 Environmental conditions Operating temp 0 50 C Storage temp 20 70 C Rel humidity 0 99 rel humidity non condensing Protection class IP20 Table 7 Technical data environmental conditions 5 8 Dimensions and weight Weight 150 g Dimensions Diameter 100 mm Height 28 mm Table 8 Technical data dimensions and weight 5 9 Approvals FCC Rule parts 15 231 Equipment class Part 15 Security R...

Page 10: ...immediately send a message with Bit 0 1 and Bit 7 1 when a motion is detected by the sensor After a detection event the EnoPuck BASIC will not react again for a time of 30 seconds 6 1 2 Detect motion The EnoPuck BASIC continuously monitors the environment by a highly sensitive vibration sensor inside the device After a phase of no detection the EnoPuck BASIC will send immediately a message Bit 1 1...

Page 11: ...ofiles EEP Each EnOcean based product sends and receives data according to at least one standardized data format The EnoPuck BASIC transmits data described as follows Cons nr EEP Description Tx ID 1 A5 07 01 Occupancy sensor with supply voltage monitor PIR Vibration EURID Table 11 Technical data EnOcean EEP for tx The following table describes in detail data send by the EnoPuck BASIC according to ...

Page 12: ...0 0 Supply voltage available SVA Supply voltage availability at DB_3 1 Supply voltage is supported Table 12 EnOcean transmit data Note The EnoPuck BASIC sends EnOcean telegrams according to the following rules Immediately when the PIR or VIB sensors detect a motion or vibration event The bits are coded as follows Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Motion detected Reserved Reserved Res...

Page 13: ...sch Gladbach Tel 49 2202 285 57 61 06 07 2021 Hauptstraße 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 6 2 2 Receive RX The EnoPuck BASIC only sends EnOcean telegrams No data is received interpreted Cons Nr EEP Description ...

Page 14: ...ave to take care of electrostatic discharge Otherwise electronics will be damaged In case of discharged batteries they can be replaced with two new AA batteries 1 5 V You have to remove carefully the four screws on the backside of the EnoPuck BASIC Tool Bit T6 Do not touch any electronic components since you could damage the device 8 Safety remarks CAUTION Risk of damage or explosion if a battery ...

Page 15: ...ontrols de www deuta controls dnet Fax 49 5734 51466 28 Keep new and used batteries away from children 9 Device labels The following labels are placed on the bottom side of the EnoPuck BASIC IC FCC ID 2AZTH AL 602 03 902 IC 27242 60203902 PMN AL 602 03 902 FVIN 1 0 HVIN 2 0 RoHS AL 602 03 902 EnoPuck Basic PN 12408 2 x Bat Typ AA Made in Germany DEUTA Controls GmbH Paffrather Straße 140 51465 Berg...

Page 16: ... could void the user s authority to operate the equipment 11 ISED Regulatory Statement This device contains licence exempt transmitter s receiver s that comply with Innovation Science and Economic Development Canada s licence exempt RSS s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference t...

Page 17: ...r 140 51465 Bergisch Gladbach Tel 49 2202 285 57 61 06 07 2021 Hauptstraße 76 32479 Hille Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 12 Dimensions drawings Diameter 100 mm Height approx 28 mm 7 mm lens cover if mounted ...

Page 18: ...e Tel 49 5734 51466 0 Technical data might change info deuta controls de www deuta controls dnet Fax 49 5734 51466 28 13 Ordering information Part name Part nr Description AL 602 03 902 EnoPuck BASIC 12408 Table sensor EnoPuck BASIC EnOcean 902 MHz sensors for vibration and PIR detector supply voltage 2x AA 1 5 V internal dimensions 100 x 28 mm PC white opaque incl adhesive pad ...

Page 19: ...6 Technical data power supply 9 Table 7 Technical data environmental conditions 9 Table 8 Technical data dimensions and weight 9 Table 9 Technical data tests and approvals 9 Table 10 Technical data standards and guidelines 9 Table 11 Technical data EnOcean EEP for tx 11 Table 12 EnOcean transmit data 12 Table 13 EnOcean data PIR and vibration message coding 12 14 Revision history Version Author Re...

Reviews: