Operation

Set the fan speed switch on the rear of the unit to the LOW, 
MED, or HI position.  Higher airflow will result in faster 
neutralization rates.  Position the unit so that the maximum 
airflow is directed at the items or area to be neutralized.  
Turn the unit ON.

When the unit is first turned on, it conducts a self-test.  The 
audible alarm will sound and then the LED will cycle through 
RED, YELLOW, and then GREEN.  The LED will remain 
GREEN during normal operation.

Balance Adjustment

The Chargebuster Overhead Ionizer is an auto-balancing 
unit.  However, tuning or manual adjustment can be 
accomplished by inserting a small screwdriver or trimmer 
adjustment tool into the balance adjustment hole located 
on the front of the unit.  To increase the output in a positive 
direction, turn the potentiometer in a clockwise direction.  
Conversely, to increase the output in a negative direction, 
turn the potentiometer in a counter clockwise direction.  
Once the desired balance point has been achieved, the 
alarm reset button must be pressed to set the balance point.  

Maintenance / Alarms

It the supply voltage drops from 110 Volts to below 85 
Volts or from 220 Volts to below 170 Volts, the unit will shut 
down, the audible alarm will beep, and the LED will blink 
RED.  The unit will automatically reset when the minimum 
voltage is restored.

Under normal conditions, the ionizer will attract dirt and dust 
(especially on the emitter electrodes).  To maintain optimum 
neutralization efficiency and operation, cleaning should be 
performed on a regular basis. 

When the unit enters shutdown mode, ionization will be 
stopped, the LED on the front of the unit will change to a 
steady RED, and the audible alarm will sound continuously.  
If the ionizer enters shutdown mode, it must be turned OFF 
and then back ON to reset the unit.

NOTE:  The AC power cord MUST be disconnected before 
the unit is disassembled for maintenance.  The emitter 
electrodes should be cleaned using the alcohol cleaners 
included or a swab wet with Isopropyl alcohol.  First, turn 
the unit OFF and unplug the power cord.  Then remove the 
back cover by disengaging the 4 screws on back.  After 
cleaning the emitter electrodes, reattach the back cover 
using the 4 screws.  Plug in the power cord and turn the unit 
back ON.

Figure 1. Desco Emit Overhead Ionizer

Description

The Desco EMIT 

50680

 / 

50681

 is a three fan, dual steady 

state DC auto-balancing overhead ionizer.   The unit 
is normally hung from the ceiling above the area to be 
neutralized.  The ionizer’s neutralization time will be best 
approximately 24” to 48” directly above the work surface 
and will increase as the distance from the unit increases.

Installation

Remove the ionizer from the carton and inspect for damage.  
Included with the unit should be:

1. Hanging kit
2. Power cord
3. Emitter point cleaner

The input voltage should be set to your specification prior 
to shipping.  It can be verified or reset by removing the top 
of the case by disengaging the 4 screws.  NOTE:  The AC 
power cord MUST always be disconnected before the unit 
is disassembled.  

Input voltage is selected with the two internal jumpers on 
JH1.  For 110 volt jumper setting, a jumper must be in place 
shorting pin 1 to 2 and another shorting pin 3 to 4.  For 
220 volt jumper setting, a single jumper must be in place 
shorting pin 2 to 3 only.

Before installing the unit, verify that the AC outlet is properly 
connected to earth ground.   The unit must have a good 
earth ground to maintain proper balance.  Install the unit in 
the desired location, making sure that the airflow will not be 
restricted.  Be sure the ON/OFF switch, located on the rear 
of the unit, is in the “OFF” position.  Plug the power cord 
into the unit and then into the appropriate AC power source.

Status of the unit can be monitored remotely via the RS485 
data ports.  Please contact the factory for the necessary 
polling utility.

TB-6545 August 2009 Page 1 of 2

Chargebuster Overhead Ionizer
Installation, Operation, and Maintenance

Made in America

TECHNICAL BULLETIN TB-6545

© 2009 DESCO INDUSTRIES INC.

Employee Owned

EMIT - 3651 Walnut Avenue, Chino, CA 91710 • (909) 664-9980 • Fax (909) 627-7449 • Website: 

DescoEMIT.com

 