9. Availability

Description

straight legs

bent legs

Quantity

palex

®

 Mini – 7 

(Expansion 7 mm)

602-800-11 

602-800-31 

602-800-55

602-801-11 

602-801-31 

602-801-55

1 piece  
10 pieces 
50 pieces

palex

®

 Medium – 10 

(Expansion 10 mm)

602-808-11 

602-808-31 

602-808-55

602-840-11 

602-840-31 

602-840-55

1 piece  
10 pieces 
50 pieces

palex

®

 Maxi – 12 

(Expansion 12 mm)

602-811-11 

602-811-31 

602-811-55

602-812-11 

602-812-31 

602-812-55

1 piece  
10 pieces 
50 pieces

 

Packages (1 piece / 10 pieces): with 1 / 10 safety key(s) 

 

Packages (50 pieces): with 1 safety key

Safety key

611-120-00

10 pieces

Universal bending tool

611-122-00

1 piece

10. Quality information

Dentaurum guarantees the perfect quality of its products. These 
recommendations are based upon Dentaurum´s own experiences. The user is 
solely responsible for the processing of the products. Responsibility for failures 
cannot be taken, as we have no influence on the processing on site.

11. Explanation of symbols used on the label

Please refer to the label. Additional information can be found at 
www.dentaurum.com (Explanation of symbols REF 989-313-00).

Information for the doctor / patient

Before the palex

®

 appliance is cemented into position, turn the spindle (screw) 

slightly 2 – 3 quarter turns in the direction of the arrow to test the function. 
Then turn back to the original position.
Turn the palex

®

 screw only in the direction of the arrow. Opening and closing 

the screw several times during the treatment can cause its malfunction. The 
finished palex

®

 appliance is cemented into position in the usual manner. Please 

observe the instructions from the cement manufacturer.
Following this, the screw is turned four times by 90° using the blue  
safety key (REF 611-120-00) for this purpose. One full 360° turn of the  
spindle = 0.8  mm expansion. 
The patient should turn the screw two times by 90° both in the morning and 
evening (according to your in structions) until the desired expansion is achieved.

#

Important:

 Use only the blue safety key supplied, as this cannot accidentally 

be swallowed.
Regular visits are recommended to monitor progress.
The palex

®

 appliance is secured against unwanted turning-back, after the 

desired degree of expansion is achieved, by fitting a ligature or blocking 
with acrylic. For stabilization the appliance should remain in the mouth for 
approximately 2 – 3 months.
A retainer should be worn following removal of the palex

®

 appliance.

 The product should not be used, if there is a known allergic reaction  
to one or more of the material components. 

Instructions for use

palex

®

 screws

(Biederman)

US

989-516-21 

  Printed by Dentaurum      Germany      10/18/B/R1-22

Â

Â

For more information on our products,  
please visit www.dentaurum.com

Â

Â

Our orthodontic technicians are available to answer  
any questions you may have regarding our products: 
 
Customer Service:  Phone 800 523 3946 

[email protected]

Date of information: 10/18
Subject to modifications

Dentaurum Inc.  |  2050 Cabot Boulevard West, Suite 100  |  Langhorne, PA 19047  I  USA  

Phone + 1 - 800 - 523 - 3946  I  Fax + 1 - 800 - 553 - 6389  |  www.dentaurum.com  I  [email protected]

Reviews: