background image

 

CITY MODEL 10

 Monitor/Display made by King Meter (K5242) 

 

 

 

 

 

 
 
 
 
 

USERS GUIDE 
K5242 LCD 

 

 

 

 

      

 
 

Summary of Contents for K5242 LCD

Page 1: ...CITY MODEL 10Monitor Display made by King Meter K5242 USERS GUIDE K5242 LCD ...

Page 2: ...er interface 7 5 3 Walk Assist Mode 7 5 4 PAS Level Selection 8 5 5 Battery Indicator 8 5 6 Speed Single Trip Odometer 9 5 6 1 Real time speed Trip display interface 9 5 6 2 Max Speed Odometer display interface 10 5 6 3 Avg Speed To Go display interface 10 5 7 Error Code 11 6 User Settings 11 6 1 Wheel Size Setting 12 6 2 Speed Limit Setting 12 6 3 Backlight Brightness Setting 13 6 4 Display Unit ...

Page 3: ...ad through the K5242 S product introduction carefully before using We will use the most concise words to inform you of all the details including the hardware installation setting and normal operation use of the display when using our display Meanwhile the introduction will also help you to solve possible confusion and barriers ...

Page 4: ...ng Meter K5242 4 1 Appearance and Dimensions 1 1 Material and Color K5242 products are made of black and white PC Under the temperature of 20 to 60 the shell material can ensure normal usage and good mechanical performance Dimension unit mm ...

Page 5: ...needs Its functions are as follows Battery power indication Speed indication Distance including single trip distance and ODO display Walk assist indication Backlight setting Error code indication Various setting parameters 2 2 Normal Display Content 2 3 Button definition There are 3 buttons on K5242 BLT In the following introduction is named as MODE is named as UP and is named as DOWN ...

Page 6: ...y repaired when error code appears 4 Installation Instruction When the e bike is powered off you can insert the connector of display and the corresponding connector of controller to complete the installation and adjust the display to a suitable angle 5 User Settings 5 1 On Off Long press MODE button then the display will work normally and the controller will power on at the same time With the disp...

Page 7: ... 10Monitor Display made by King Meter K5242 7 5 2 User interface 5 3 Walk Assist Mode Press and hold the DOWN button for 2 seconds to enter the Walk assist mode The E bike will travel at a constant speed of 6km h ...

Page 8: ...n to switch the PAS level in the main interface the motor output power will be changed accordingly by the PAS level of E bike The default range of PAS level is 0 5 levels Level 1 is the lowest output level and the level 5 is the highest output power level of the motor PAS level indicator 5 5 Battery Indicator The battery power is shown as a percentage bar When the battery is fully charged the powe...

Page 9: ...6 1 Real time speed Trip display interface When display is powered on it shows the real time speed and single trip mileage interface by default When the speed is zero long press MODE and DOWN button for 2 seconds and the current single trip mileage will be cleared After the display is shut down and restarted the single trip mileage will not be cleared ...

Page 10: ...eter mileage data The Max speed represents the maximum speed during this ride and the Odometer mileage is the total mileage of the E bike 5 6 3 Avg Speed To Go display interface Short press MODE button again to switch to the Avg speed and To Go mileage display interface The Avg speed represents the average speed during this ride and the To Go mileage represents the remaining mileage that the E bik...

Page 11: ... error code For the definition of detailed error codes see appendix 1 The fault can only exited when the fault is eliminated and the E bike cannot continue to drive after a fault occurs 6 User Settings When there is no speed in the power on state press and hold the UP and DOWN button at the same time for 2 seconds and the display will enter the setting interface ...

Page 12: ...rough UP and DOWN button to ensure the accuracy of the speed display and mileage display Long press MODE button to return to the normal interface 6 2 Speed Limit Setting Short press MODE button enter the speed limit setting option The optional range of the maximum speed setting is 17Km h to 45Km h 11MPH to 28 MPH It can be set by UP and DOWN button The default setting is 45Km H 28MPH Long press MO...

Page 13: ... brightness 3 is the brightest The default value is 3 Long press MODE button to return to the normal interface 6 4 Display Unit Setting Short press MODE button to enter the Unit setting option The setting parameters are Km h and Mile h Km h or Mile h can be selected by pressing UP and DOWN button Km h means the unit is metric system and MPH means the unit is Imperial system The default setting is ...

Page 14: ...d Warranty Scope I Warranty Information 1 King Meter will be responsible for all faults arising during normal operation that are caused by a quality defect 2 The warranty time is 24 months from the day the display leaves the factory II The following are not covered by warranty 1 Shell opened 2 Connector damaged 3 After display out of factory the shell is scratched or damaged 4 Lead wire of display...

Page 15: ...he initial state 23 Motor phase problem Check whether the phase wires are in good condition Check whether the motor phase line is well connected to the controller 24 Motor Hall defect No Hall controller check whether the phase wire is in good condition With Hall controller check whether the Hall outlet is good 25 Brake Failed Check whether the brake lever is reset before power on 30 Communication ...

Page 16: ...CITY MODEL 10Monitor Display made by King Meter K5242 16 CITY MODEL 10Monitor Display made by King Meter K5242 ...

Reviews: