background image

www.deltapowersolutions.com

Delta UPS – Agilon Family 

VX Series, Line-interactive

1000 VA

Installation & Operation Quick Guide

ENGLISH

Package Inspection

1

No.

Item

Q'ty

1

UPS

1 PC 

2

Quick Guide

1 PC 

3

USB Cable

1 PC 

4

Output Power Cord (10A)

1 PC 

Remove the UPS from its package and inspect it for damage that may 

have occurred during shipping. If any damage is discovered, re-pack 

the unit and return it to the place of purchase.

Front Panel & Rear Panel

2

   

No.

Item

1

LCD Touch Panel

2

ON/ OFF Button

3

Output Socket

4

AC Input

5

Circuit Breaker

6

USB Port

Operation

3

y

y

Placement

Install the UPS in a protected area that is free of excessive dust and 

has adequate air flow. Place the UPS away from other units at least 

20 cm to avoid interference. For best performance, keep the indoor 

temperature between 0° C and 40° C.

y

y

Connect to Utility Power

Connect the AC power cord to the utility power. Then, the UPS will 

start to charge its inside battery (batteries). For best result, charge the 

battery (batteries) for 6 hours prior to initial use. It is not recommended 

to connect the UPS’s AC power cord to any generator. 

y

y

Plug in Equipment

Plug your equipment to the Output Socket on the rear panel of the 

UPS.

NOTE:

Make sure that the UPS is powered on to protect all important 

devices from data loss during power failure.

WARNING:

  

NEVER

 connect a laser printer or scanner to the Output 

Socket  of the UPS. The equipment may draw significant 

power to overload the UPS.

y

y

Connect to USB Port and Install Software

Connect one end of the supplied USB cable to your PC and the other 

to the USB port located at the rear of the UPS. Download the latest 

version of ViewPower software (http://www.deltapowersolutions.com/

en/mcis/600va-1500va-single-phase-ups-vx-series-software-download.

php) to your hard drive. Follow on-screen instructions to complete the 

software installation.

y

y

Turn On/ Off the UPS

When the UPS is OFF, press the ON/ OFF Button to turn on the UPS 

and the LCD will be on. When the UPS is ON, press the ON/ OFF 

Button to turn off the UPS and the LCD will shut off. 

y

y

Storage

All connected equipment should be turned off, then disconnect from 

the UPS to avoid battery drain. Unplug the UPS from the wall outlet. 

Then turn off the UPS for storage.  Store the UPS unit covered and 

upright in environments where the ambient temperature is -20°C to 
50°C with its battery fully charged.

Continue to the Next Page

 



LCD Display

4

y

y

Operation Display:

UPS    Mode                                                

LCD Touch Panel

Description

UPS 

Power On

When the UPS is powered 

on, it will enter this mode 

for 4 seconds.

AC Mode

When AVR is functioning, 

 icon will flash every 

second.

LCD information will be 

displayed in the following 

order when the LCD         

is touched.                                        
1.  Output  voltage                                   

2. Input voltage                         

3. Load level                          

4. Battery capacity 

Overload 

In AC 

Mode

icon will flash.

When overload occurs, 

alarm will beep every 0.5 

second.

Battery               

Mode

When battery level is low,    

 

icon will flash.

Alarm will beep every 

10 seconds and LCD 

information will be 

displayed in the following 

order when the LCD  

is touched.                                     
1. Output voltage                 

2. Input voltage                  

3. Load level                                 

4. Battery capacity

Overload 

In Battery 

Mode

icon will flash.

When overload occurs, 

alarm will beep every 0.5 

second.

NOTE:

If backlight shuts off, you can activate it by touching the screen.

y

y

Fault Code Table:

Fault Condition LCD Touch Panel

Solutions

Output Short 

Circuited

Disconnect short-circuited 

loads and restart the UPS 

again.

Overload Fault

Disconnect all output loads 

and restart the UPS again.

Over Charge 

Fault

Call for service immediately.

Battery Too Low 

Fault

Please replace the battery 

(batteries).

Battery Mode 

Output High Fault

Call for service immediately.

Over 

Temperature

1. Turn off the UPS and wait    

    for cooling.   
2. Or remove excessive 

    loads and wait for cooling.

If any fault alarm occurs, please call for service immediately.

(Front Panel)

(Rear Panel)

1

2

6

3

4

5

Reviews: