Страница 1: ...EASYLIFE SUSTAINABLE COMFORT MW 2000377 4 Kaliko Split Georgia Serbia en User Guide Thermodynamic water heater KALIKO SPLIT TWH Split WH 150 E TWH Split WH 200 E Serv ref SODU 2 M R1 ...

Страница 2: ...using the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer service organisation can assist with this We hope you enjoy years of problem free operation with the product ...

Страница 3: ... 2 10 Displaying the measured values 12 3 Maintenance 14 3 1 General 14 3 2 Maintenance operation intervals 14 3 3 Operate the safety valve or unit 14 4 Troubleshooting 15 4 1 Resolving error codes 15 4 2 List of error codes 15 4 3 Checks after a disconnection of the mains supply 15 5 Warranty 17 5 1 General 17 5 2 Terms of warranty 17 6 Appendix 18 6 1 Symbols used 18 6 1 1 Symbols used in the ma...

Страница 4: ... refrigerant leakage 1 Switch off the appliance 2 Open the windows 3 Do not use a naked flame do not smoke do not operate electrical contacts 4 Avoid contact with the refrigerant Danger of frost injuries 5 Evacuate the property 6 Contact a qualified professional Danger of electric shock Before any work switch off the mains supply to the thermodynamic water heater Important Only qualified professio...

Страница 5: ...Warning Respect the maximum water inlet pressure to en sure correct operation of the appliance referring to the chapter Technical Specifications Warning In order to limit the risk of being scalded the in stallation of a thermostatic mixing valve on the domestic hot water flow pipes is obligatory Warning Only qualified professionals are authorised to work on the heat pump and the heating system Cau...

Страница 6: ...ntification If the R134a refrigerant is mixed with air it may cause pressure surges in the refrigeration pipes and lead to an explosion and other hazards Tab 3 Composition of Information on the R134a Name Proportion Number CE Number CAS GWP 1 1 1 1 2 Tetrafluoroethane R134a 100 212 377 0 811 97 2 1430 1 Global Warming Potential Tab 4 First aid If inhaled Evacuate the subject from the contaminated ...

Страница 7: ...ive equipment Do not inhale the vapour Evacuate the hazardous area Stop the leakage Eradicate all sources of ignition Ventilate the spillage area mechanically risk of asphyxia Cleaning Decontamination Allow residual product to evaporate Tab 7 Personal protective equipment Respiratory protec tion If ventilation is insufficient AX type cartridge mask In confined spaces self contained breathing appar...

Страница 8: ...ecifications given in this document Our liability as manufacturer may not be invoked in the following cases Failure to abide by the instructions on installing the appliance Failure to abide by the instructions on using the appli ance Faulty or insufficient maintenance of the appliance 1 4 2 Installer s liability The installer is responsible for the installation and initial commissioning of the app...

Страница 9: ... provided with the appliance Call on a qualified professional to carry out installation and initial commissioning Get your installer to explain your installation to you Have the required inspections and maintenance car ried out by a qualified installer Keep the instruction manuals in good condition close to the appliance 1 Safety 7647125 v03 11092017 TWH Split WH 9 ...

Страница 10: ...iday mode 6 Operating indicator light Indicator light on Domestic hot water production active Indicator light off Holiday mode 2 3 Description of the control panel display 1 Hybrid mode operating 2 Heating temperature Domestic hot water temperature Error code detected 3 Error detected 4 Forced electrical back up in operation 5 Compressor running 6 Time display 7 Timer program display 8 Off peak ra...

Страница 11: ...mperature settings by pressing the key The domestic hot water temperature value will flash 2 Set the domestic hot water temperature to the lowest possible set ting to save energy without dropping below 55 C by pressing the or keys If there is insufficient hot water increase the set point value 3 Confirm by pressing the key 2 7 Programming the operating ranges The operating ranges of the thermodyna...

Страница 12: ... a few seconds 2 9 Activate forced electrical back up The forced electrical back up mode enables domestic hot water to be pro vided more quickly thanks to the simultaneous operation of the heat pump and electrical back up 1 Activate forced electrical back up by pressing the key The Electrical Heating icon flashes When the set temperature of the hot water is reached the control panel returns to Aut...

Страница 13: ...tion of the heat pump from midnight Wh Energy consumption of the immersion heater from midnight Wh Total runtime for the thermodynamic water heater hours Total duration of compressor operation hours Total runtime for the immersion heater hours Operating mode thermodynamic water heater off heat pump on electrical back up on Fan speed fan off low speed high speed First error code Second error code T...

Страница 14: ... Installer User Operate the safety valve or unit once a month X Tab 13 Outdoor unit maintenance Maintenance operations on the outdoor unit Periodicity Installer User Clean the casing using a damp soft cloth once a year X Check the cleanliness of the outdoor unit fan once a year X Tab 14 Maintenance of the domestic hot water tank Operations Periodicity Installer User Clean the casing using a damp s...

Страница 15: ...d the control panel Water temperature sensor T5L error Evaporation temperature sensor T3 error Air temperature sensor T4 error Air suction temperature sensor Th error Air discharge temperature sensor Tp error Tab 16 Px type error codes Code Description High pressure error Electrical overconsumption error on the compressor Discharge temperature error too high Air temperature information outside the...

Страница 16: ...For more information see Activate Deactivate the Holiday mode page 11 Setting the time page 11 Programming the operating ranges page 11 4 Troubleshooting 16 TWH Split WH 7647125 v03 11092017 ...

Страница 17: ...le for material damage intangible los ses or physical injury resulting from an installation that does not comply with Legal or regulatory requirements or provisions laid down by the local au thorities National or local regulations and special provisions relating to the instal lation Our manuals and installation instructions in particular in terms of regular maintenance of the appliances Our warran...

Страница 18: ...e installing and commissioning the appliance carefully read the instruction manuals provided 4 Dispose of used products through an appropriate recovery and re cycling structure 5 Caution danger of electric shock live parts Disconnect the mains power prior to carrying out any work 6 Electrical back up 7 CE Marking equipment conforming to European legislation 8 NF Marking equipment that respects Fre...

Страница 19: ... 1 Relevant standards EN 60335 2 21 EN 60335 2 40 Electromagnetic Compatibility Directive 2014 30 EU Generic standards EN 61000 6 3 EN 61000 6 1 Relevant Standard EN 55014 6 2 3 Directive 97 23 CE This product conforms to the requirements of European Directive 97 23 EC article 3 paragraph 3 on pressure equipment 6 2 4 Ecodesign Directive This product conforms to the requirements of European Direct...

Страница 20: ...stribution system and the dimensioning of the products in relation to building size and characteristics Water heating energy efficiency class of package under average climate Water heating energy efficiency of package under average climate Auxiliary electricity Solar contribution Water heating energy efficiency of water heater from fiche of solar device Colder Warmer Water heating energy efficienc...

Страница 21: ...r heater is suitable to use and the corresponding water heating energy efficiency and annual electricity con sumption 3 Thermostat temperature setting C 55 00 55 00 Sound power level LWA indoors 1 dB 15 15 Ability to function during off peak hours 1 No No Enabled smart control settings 4 No No Water heating energy efficiency under colder warmer climate conditions 90 00 154 00 85 00 144 00 Annual e...

Страница 22: ...tenance carried out by user no 1 Date __________ No Remarks By Signature 1 2 3 Tab 20 Maintenance carried out by user no 2 Date __________ No Remarks By Signature 1 2 3 Tab 21 Maintenance carried out by user no 3 Date __________ No Remarks By Signature 1 2 3 Tab 22 Maintenance carried out by user no 4 Date __________ No Remarks By Signature 1 2 3 Tab 23 Maintenance carried out by user no 5 Date __...

Страница 23: ...hnological information contained in these technical instructions as well as any drawings and technical de scriptions supplied remain our property and shall not be multiplied without our prior consent in writing Subject to alterations ...

Страница 24: ...DE DIETRICH THERMIQUE 57 rue de la Gare F 67580 MERTZWILLER BP 30 MW 8000005 12 7647125 v03 11092017 7647125 001 03 ...