1
Technical changes reserved - 2022
Assembly and Installation Instructions
Easy-UV 4-8 m³/h and 5-15 m³/h
Pay proper attention to these installation instructions. If the following instructions are not followed,
exactly, the manufacturer cannot accept liability for any resulting damage to the device itself, the
environment, property, or personal injury.
Your
safety
is
our
concern!
1.
Assembly:
1.1
The Easy-UV is built according to modern state of the art technology and safety measures. It is important to keep in mind that this
device is made to sterilize bathing water of swimming pools, whirlpools and swim ponds, while the pump is running. It is strictly
forbidden to change and/or modify the device. Anybody involved with the installation, start-up, use, maintenance, and/or repair of
this device must be qualified and carefully follow the instructions.
1.2
This device has not been designed for use by individuals (including children) with physical, mental or sensory disabilities, or people
who lack the necessary experience and/or knowledge unless under the supervision of someone entrusted with their safety or
instructed by that person in how the device should be used.
1.3
Only a specialized electrical technician may operate the device following the DIN VDE 0100 safety standards.
1.4
If the Easy-UV is handled incorrectly the manufacturer is not responsible for potential damages, accidents, or injuries.
1.5
The device gets installed into the water circuit and does not need its own pump. To avoid the level of efficiency from dropping, install
the Easy-UV after the filter. This will keep dirt particles from washing into the device. We also recommend the installation of the
Easy-UV before the heat exchanger, because a rise in temperature would lower the level of efficiency.
1.6
Mount the device with the three-part connector to the water circuit. For maintenance we recommend to install a ball valve onto
the primary and secondary pipe.
2.
Corrosion Prevention:
2.1
The Easy-UV device should be mounted in a dry place. Dripping water containing iron could damage the stainless steel casing.
2.2
Be careful not to wash any metals into the Easy-UV device when connecting it to the water circuit.
2.3
The Easy-UV should be mounted so it can always be completely full of water or completely empty. During the off-season, it can
also be completely drained.
2.4
To avoid corrosion make sure not to exceed the following water parameters:
Chloride content:
max. 500 mg/l
Free chlorine:
max. 1 mg/l
PH:
max. 6,8
–
7,8