Trouble Shooting Check List

a) 

MOTOR RUNS WHEN SWITCHED ON BUT DOES NOT PUMP.

 

1.  Suction line and pump body not filled with water.

 

2.  Air leaks in suction lines or suction pipe not under water.

 

3.  Air trapped in suction lines (also possible with flooded suction due to 

uneven rise in piping; eliminate humps and hollows).

 

4.  No water at source or water level too low.

 

5.  Valve on suction lines closed.

b) 

PUMP SWITCHES ON AND OFF FREQUENTLY (CYCLING)

 

1.  Check that tank air pressure is correct - see above.

 

2.  Leaking taps, float valves etc. check plumbing.

 

3.  Leaking check valve/foot valve.

c) 

MOTOR DOESN’T START WHEN SWITCHED ON.

 

1.  Power not connected.

 

2.  Supply voltage too low.

 

3.  “Over temperature” cut-out tripped.*

 

4.  Motor not free to turn eg. a jammed impeller.

 

5.  Internal motor fault.

Checking and Replenishing Tank Air Charge

Supercell “P” Pressure Tanks do not require regular checks 

under normal operating conditions,  If air charge adjustment 

is required then follow the following procedures:

1.  Release all water pressure from the pressure tank by 

switching off the pump at the power point, and opening the 

closet tap.  For above ground supply  tanks it is necessary 

to close the gate valve between the supply tank and the 

pump.

Leave tap open during air replenishment.
2.  When all water pressure has been released from the system, check air 

pressure at air valve on top of pressure tank.  The standard pre-charge 

pressure reading should be 165kPa for X50 and 190kPa for X70 and X90 

models.  In any case the pre-charge should be set at 15kPa below cut-in 

pressure.

3.  If necessary, replenish air charge to the correct pressure indicated.  Ensure 

that a tap in outlet piping of pumps is open during replenishment of air 

precharge.

Period Checks

Flushing:  Depending on the quality of the pumped water, from time to time, 

your tank may required flushing to remove settled fines such as mud or sand.  

If sand or mud is allowed to stay in the tank, it will accelerate wear on the 

internal lining and shorten your tank’s life.
Safely disconnect the tank from the water supply, discharge all air from the 

tank and flush the tank several times with clean water.  Once the flushing 

water is clean, reconnect the tank and recharge the air as per above.
External inspection:  A tank in good order will not leak, but over time due to 

damage through rough handling, impacts or grit and/or impurities in the water,  

the tank shell may fail and/or leak.  Should the tank leak or show signs of 

possible failure, the tank should be immediately disconnected and replaced.

Please pass these instructions on to the operator of this equipment.

*NOTE: For protection, the Davey pump motor is fitted with an 

automatic “over temperature” cut-out.  Constant tripping of this 

overload device indicates a problem eg. low voltage at pump, 

excessive temperature (above 45

o

C) in pump enclosure.

Care should also be taken when servicing or disassembling pump to 

avoid possible injury from hot pressurised water.  Unplug pump, relieve 

pressure by opening a tap on the discharge side of the pump and allow 

any hot water in the pump to cool before attempting to dismantle.

WARNING: When servicing or attending pump, always ensure power

is switched off and lead unplugged.  Electrical connections should be

serviced only by qualified persons.

During servicing, use only approved, non-petrochemical based oring 

and gasket lubrication.  If unsure, consult your Davey Dealer for advice.

 

WARNING: Do not use hydrocarbon based or hydrocarbon propelled

 

sprays around the electrical components of this pump.

In accordance with AS/NZS 60335.2.41 we are obliged to inform you that this 

pump is not to be used by children or infirm persons and must not be used as a 

toy by children.

W

ARNING: Failure to follow these instructions and 

comply with all applicable codes may cause serious  bodily injury and/or property damage.

NOTE: Prior to installation remove the red transport  plugs & associated seals from the suction and/or  discharge ports.

CAUTION: To prevent personal injury, ensure all water pressure is released 

from the pressure system prior to work being performed.

NOTE: During air replenishment the tank should be externally inspected.  Any 

signs of leakage from the tank may indicate a need for immediate replacement.

WARNING: Do not use tank if it leaks or shows signs of corrosion or damage.

Davey

®

 Repair or Replacement Guarantee

In the unlikely event in Australia or New Zealand that this Davey pr

oduct develops any malfunction within two years of the date of original pur

chase due to 

faulty materials or manufactur

e, Davey will at our option r

epair or r

eplace it for you fr

ee of char

ge, subject to the conditions below

.

Should you experience any difficulties with your Davey pr

oduct, we suggest in the first instance that you contact the Dav

ey Dealer fr

om which you 

pur

chased the Davey pr

oduct. Alter

natively you can phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or 

send a written letter to Davey at the addr

ess listed below

. On r

eceipt of your claim, Davey will seek to r

esolve your difficulties or

, if the pr

oduct is faulty or 

defective, advise you on how to have your Davey pr

oduct r

epair

ed, obtain a r

eplacement or a r

efund.

Your Davey T

wo Y

ear Guarantee naturally does not cover normal wear or tear

, r

eplacement of pr

oduct consumables (i.e. mechanical seals, bearings or 

capacitors), loss or damage r

esulting fr

om misuse or negligent handling, impr

oper use for which the pr

oduct was not designed or advertised, failur

e to 

pr

operly follow the pr

ovided installation and operating instructions, failur

e to carry out maintenance, corr

osive or abrasive water or other liquid, lightning 

or high voltage spikes, or unauthorized persons attempting r

epairs.  Wher

e applicable, your Davey pr

oduct must only be connected to the voltage shown 

on the nameplate.

Your Davey T

wo Y

ear Guarantee does not cover fr

eight or any other costs incurr

ed in making a claim. Please r

etain your r

eceipt as pr

oof of pur

chase; you 

MUST

 pr

ovide evidence of the date of original pur

chase when claiming under the Davey T

wo Y

ear Guarantee. 

Davey shall not be liable for any loss of pr

ofits or any consequential, indir

ect or special loss, damage or injury of any kind whatsoever ar

ising dir

ectly 

or indir

ectly fr

om Davey pr

oducts. This limitation does not apply to any liability of Davey for failur

e to comply with a consumer guarantee applicable to 

your Davey pr

oduct under the Australian or New Zealand legislation and does 

not affect any rights or r

emedies that may be available to you under the 

Australian or New Zealand Consumer Legislation.

In Australia, you ar

e entitled to a r

eplacement or r

efund for a major failur

e and for compensation for any other r

easonably for

eseeable loss or damage. Y

ou 

ar

e also entitled to have the goods r

epair

ed or r

eplaced if the goods fail to be of acceptable quality and the failur

e does not amount to a major failur

e.

Should your Davey pr

oduct r

equir

e r

epair or service after the guarantee period; contact your near

est Davey Dealer or phone the Davey Customer Service 

Centr

e on the number listed below

.

For a complete list of Davey Dealers visit our website (davey

.com.au) or call:

Installation and operating instructions ar

e included with the pr

oduct when pur

chased new

They may also be found on our website.

AUSTRALIA

Customer Service Centre

6 Lakeview Drive, Scoresby, Australia 3179 Ph: 

1300 232 839

Fax: 

1300 369 119

Email: [email protected] Website: davey.com.au

Davey Water Products Pty Ltd

Member of the GUD Group

ABN 18 066 327 517

NEW ZEALAND

Customer Service Centre

7 Rockridge Avenue, Penrose, Auckland 1061 Ph: 

0800 654 333

Fax: 

0800 654 334

Email: [email protected] Website: daveynz.co.nz

® Davey is a r

egister

ed trademark of Davey W

ater Pr

oducts Pty Ltd.  © Davey W

ater Pr

oducts Pty Ltd 2016.

P/N 48660-10

Reviews: