Summary of Contents for PWR-2400

Page 1: ......

Page 2: ...ed in any form or by any means or for any purpose without the express written permission of Datalogic S p A and or its affiliates Datalogic and the Datalogic logo are registered trademarks of Datalogi...

Page 3: ...tion 2 2 PRE INSTALLATION CHECKLIST 4 System Wiring DC Output 4 System Wiring AC Input 4 System Wiring Test 4 3 MECHANICAL INSTALLATION 5 3 1 Cabinet Mounting 5 3 2 Cable Insertion 6 4 ELECTRICAL CONN...

Page 4: ...his symbol alerts the user they are about to perform an action involving either a dangerous level of voltage or to warn against an action that could result in damage to devices or electrical shock It...

Page 5: ...ogic products are mainly designed for integration purposes into more complex systems For this reason it is under the responsibility of the system integrator to do a new risk assessment regarding the f...

Page 6: ...Filtered Air Intake Filtered Cooling Fan Out AC Line Input Compression Connector DC Output Compression Connectors AC Line Input Terminal Block 7 8 9 10 Thermal magnetic circuit breakers 24 Vdc Termina...

Page 7: ...ides protection through a Miniature circuit breaker MCB 4 A 1p C Char For each monophase switching power supply two output power supply status monitoring signals DC OK are provided to connect to an op...

Page 8: ...vided where overload power is supplied as explained in the examples below Example 1 Up to 120 power overload The overload is supplied for approximately 12 seconds and then is reduced Voltage and Curre...

Page 9: ...This procedure is repeated until the excessive current overload is resolved Figure 5 Overload Protection at 125 Example 3 150 power overload The overload is supplied for approximately 4 seconds and t...

Page 10: ...ckage See par 3 1 SYSTEM WIRING DC OUTPUT 3 Connect your devices to the PWR according to the information in par 4 2 SYSTEM WIRING AC INPUT 4 To comply with EN 60950 1 2007 par 1 7 2 2 par 2 7 1 par 2...

Page 11: ...Mount the bracket to the cabinet 2 Mount the cabinet to the frame Figure 7 Mounting Brackets IMPORTANT The cabinet must be installed vertically in such a way that the key lock is no higher than 1 90 m...

Page 12: ...e 9 Prepare each cable by stripping the wires and inserting the compression connector nut Pass the cable through the compression connector and make sure there is enough length to easily reach the corr...

Page 13: ...ONNECTIONS 4 1 DC VOLTAGE TERMINAL BLOCK Figure 10 PWR 2400 DC Output Power Connections If the 93ACC0084 Air Cleaning System is used make sure to power it through the F51 protected block DC Outputs 4...

Page 14: ...d reading station application The power supply unit is connected to the camera illuminators according to the following diagram power supply side See also the AV7000 Reference Manual or your applicatio...

Page 15: ...400 power supply by cutting off the cable s male Amphenol connector and connecting the wires to the PWR 2400 according to the table below CVL 2389 Cable to AI7000 Wire Color Meaning White GND 0 V Gree...

Page 16: ...rotection For primary wiring use a 3 conductor cable between 4 mm2 10 mm2 11 AWG 7 AWG for every conductor Choose the overall cable diameter and UL Listed conduits accordingly The AC input cable must...

Page 17: ...an it with compressed air or replace it with new filter material The filter type material to use is Class G3 according to norm EN 779 3 Reinsert the clean filter and close the filter grill 6 2 COOLING...

Page 18: ...20 A for each power module 22 A up to 40 C ambient temp for each power module ENVIRONMENTAL FEATURES Operating Temperature 0 to 50 C 32 to 122 F Storage Temperature 20 to 70 C 4 to 158 F Humidity 5 9...

Page 19: ...LECTRICAL DIAGRAMS 13 A A ELECTRICAL DIAGRAMS PWR 2400 ELECTRICAL DIAGRAM The PWR 2400 components are electrically connected as displayed in the following diagram Figure 13 PWR 2400 Electrical Diagram...

Page 20: ......