background image

QUESTIONS? 

Ask the experts at POSMicro.com.

  

1.800.241.6264

   Live Chat Now

   [email protected]

Monday - Friday 6 AM to 5 PM Pacific 

Time

BULk DISCOUNTS

FREE SHIPPING*

SE HaBLa 

ESpa

ñ

OL

*Free ground shipping to the continental USa on orders over $100.

For Help Call 

1.800.241.6264

Datalogic PowerScan
D8300 Manual

More information available at  

POSMicro.com

Summary of Contents for PowerScan D8300

Page 1: ...pport POSMicro com Monday Friday 6 AM to 5 PM Pacific Time Bulk Discounts FREE SHIPPING SE Habla Espa ol Free ground shipping to the continental USA on orders over 100 For Help Call 1 800 241 6264 Dat...

Page 2: ...PowerScan D8330 M8300 M8300 DK Reference Manual...

Page 3: ...t all notices appear on any reproductions of the documentation Should future revisions of this manual be published you can acquire printed versions by contacting your Datalogic representative Electron...

Page 4: ...RK LAYOUTS 18 3 1 Stand alone Layouts 18 3 1 1 Point to Point Reader Layout 18 3 1 2 Stand Alone Layout with Multiple Readers 18 3 1 3 Multiple Stand Alone Layouts 19 3 1 4 C BOX Layout 20 3 2 Multidr...

Page 5: ...ERENCES 160 5 1 RS 232 Parameters 160 5 1 1 Handshaking 160 5 1 2 ACK NACK Protocol 161 5 1 3 FIFO 162 5 1 4 RX Timeout 163 5 2 Pen Parameters 163 5 2 1 Minimum Output Pulse 163 5 2 2 Conversion to Co...

Page 6: ...y 184 5 10 Display Parameters Some M8300 Models only 185 5 10 1 Display Mode 185 5 11 Configuration Editing Commands 186 5 12 Custom Default Configuration 187 5 13 Code Type Recognition 187 5 14 Confi...

Page 7: ...1 6 4 1 PowerScan M8300 keypad 201 6 4 2 PowerScan M8300 DK 16 key keypad 202 7 TECHNICAL FEATURES 203 7 1 PowerScan D8330 203 7 2 PowerScan M8300 204 7 3 PowerScan M8300 DK 16 Key Model 205 7 4 BC 80...

Page 8: ...8300 READERS Figure A PowerScan D8330 M8300 Series Readers Figure B PowerScan M8300 Series Readers with Display LEDs Keypad Display Laser Output Window Laser Output Window POWERSCAN M8300 Battery Cove...

Page 9: ...erly configured scanners Radio RX Timeout set to keep the radio awake linked to that base through a bind or a join sequence and within radio range coverage will emit a beep sequence once every 2 secon...

Page 10: ...Hz for USA version and allows bi directional communication between the base station and the host PowerScan M8300 also includes a display and either a 3 or 16 key push button keypad Thanks to these fea...

Page 11: ...2 1 POWERSCAN D8330 INTERFACE CABLE CONNECTIONS The PowerScan D8330 reader incorporates a multi standard interface which can be connected to a Host by plugging the correct interface cable into the con...

Page 12: ...ing on the plastic boot is facing out with the arrow pointing towards the front of the scanner Insert the cable into the socket of the plastic boot Insert the cable spacer into the cable wire and slid...

Page 13: ...e correct interface cable into the Host connector placed on the base of the cradle In addition the cradle must be connected to an external power supply Disconnecting the BC 80X0 Cable To disconnect th...

Page 14: ...INSTALLATION 5 2 3 RS 232 CONNECTION 2 4 USB if required...

Page 15: ...POWERSCAN D8330 M8300 M8300 DK 6 2 5 IBM USB POS if required...

Page 16: ...INSTALLATION 7 2 6 WEDGE CONNECTION 2 7 PEN EMULATION CONNECTION...

Page 17: ...s possible thanks to the RS 485 connector on the front panel of the cradle All cradles are connected together within the bus system through the Datalogic RS 485 splitter cable CAB 428 part number 90A0...

Page 18: ...rop cables note the following Pin 8 or 7 can be connected only if the power has to be propagated from a cradle to a STARGATE base station or STAR Box converter via the cable Pins 5 or 4 should always...

Page 19: ...hat can be selected via jumper For this selection you must open the device No Termination Static Dynamic Terminator for Multidrop Network Static termination works for all network configurations Howeve...

Page 20: ...eries in your PowerScan M8300 scanner press the black button or unscrew the fixing screw on the handle cover and extract the battery pack from the reader handle When the batteries are extracted from t...

Page 21: ...4 rubber feet 1 horizontal base 1 inclined base The cradle either BC 80X0 or C 8000 can be mounted for portable or fixed desktop usage or it can be fixed to a wall The horizontal base allows portable...

Page 22: ...on the inclined base for a more ergonomic taking out and insertion of the reader onto the cradle Horizontal base Top View Bottom View Inclined base Top View Bottom View Mounting Tabs 4 Mounting Holes...

Page 23: ...he BC 80X0 cradle insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight Fixed Desktop Use For fixed desktop installation use the adhesive strips or fi...

Page 24: ...ate hole on the body of the cradle and screw it clockwise until tight For mounting with screws 1 Position the cables to be connected to the BC 80X0 C 8000 cradle along the dedicated channels as shown...

Page 25: ...10 2 Wall Mounting 1 Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradle 2 Position the cables to be connected to the BC 80X0 C 8000 cradle along the dedicat...

Page 26: ...he mounting screws 3 Using the mounting holes on the base as a pattern mark the wall where you desire to mount the BC 80X0 C 8000 4 Drill the appropriate size holes and insert the threaded dowels not...

Page 27: ...c system layouts that can be employed Stand alone systems including Point to Point layouts and Multidrop STAR System Networks 3 1 STAND ALONE LAYOUTS 3 1 1 Point to Point Reader Layout 3 1 2 Stand Alo...

Page 28: ...esses Multiple Stand alone Systems in the Same Area Since the cradles can communicate to multiple PowerScan M8300 readers you might find it useful to employ one or more C 8000 battery chargers in addi...

Page 29: ...ner network This allows the flexibility of a hand held reading station integrated into a variety of fixed scanning applications so that all readers both fixed and hand held in the system provide commu...

Page 30: ...TE base stations Example Multidrop STAR System Network with Host as Master In this layout the Host acts as the Master using STAR Link software The Host is connected in RS 232 to a STAR Box converter w...

Page 31: ...PEN Emulation The Master is then connected to the slaves in the RS 485 network In this way the slave cradles provide communications between a single Host and all 2 8 3 readers in the system STARGATE b...

Page 32: ...has address 0188 and one Slave cradle with address 0001 the response is 188 1 Alive xxxx Executes a continuous Alive request to the slave xxxx in order to monitor the performance of the connection A d...

Page 33: ...more sections following the procedures given for each group available at the top of each page of configuration 4 Read the Exit and Save Configuration code ONCE available at the top of each page of con...

Page 34: ...he Host by either the BC 80X0 cradle par 4 5 or by the STAR Modem radio modem par 4 5 2 STAR System applications allow communication with the Host through an RS 485 network by the STARGATE RF base sta...

Page 35: ...nd where it is not necessary to set the Date and Time parameters To rapidly configure your point to point application 1 Apply the bind address label onto the BC 80x0 base station as indicated in the B...

Page 36: ...parameters code below 1 Restore PowerScan M8300 Default o Follow the procedure below to set the radio address and bind PowerScan M8300 to the BC 80X0 cradle 2 Enter Configuration 3 Set Date IA six di...

Page 37: ...he cradle Any previously bound reader will be excluded To connect several readers to the same cradle see the following paragraph 4 5 1 Using Multiple M8300 Series Readers with Same Cradle Bind RN0 I T...

Page 38: ...see previously described configuration procedure Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join step 7 7 Jo...

Page 39: ...nicate with STAR Modem in Stand alone Mode follow the procedure in par 4 5 substituting steps 6 and 7 with those below 6 STAR Modem Address RSR Read the code above and the four digit address of the ST...

Page 40: ...such as STARGATE RF base stations 1 Restore PowerScan M8300 Default o 2 Enter Configuration 3 Set Date IA six digits for Day Month and Year DDMMYY 4 Set Time IB four digits for Hour and Minutes HHMM 5...

Page 41: ...the First STAR System device in the system 8 Set Last STAR System Address RTT Read the code above and the four digit address of the Last STAR System device in the system Whenever the system is compos...

Page 42: ...to 1999 All cradles used in the network must have different addresses 2 Exit and Save configuration 3 Read the Bind code to pair the PowerScan M8300 to the BC 8060 cradle for configuration Bind RN0 I...

Page 43: ...ww scanning datalogic com For BC 8060 Master Network Layouts see par 3 2 The network configuration parameters can be changed either through the Datalogic Aladdin configuration software running on the...

Page 44: ...8 INTERFACE SELECTION Read the interface selection code for your application RS 232 Standard CP0 POS TERMINALS Nixdorf Mode A CM2EC0 Fujitsu ICL Mode CM1 CM0 For POS terminal default settings refer to...

Page 45: ...06 CP504 IBM Terminals 31xx 32xx 34xx 37xx To select the interface for these IBM Terminals read the correct KEY TRANSMISSION code Select the KEYBOARD TYPE if necessary default advanced keyboard KEY TR...

Page 46: ...d Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is ON IBM AT ALT mode CP507 PC Notebook ALT mode CP50...

Page 47: ...he start up phase ends correctly The reader s LED stops blinking and the reader emits the beep OK signal In rare cases if the Host does not supply sufficient power to the device a dialog box will appe...

Page 48: ...APPLE UA05 F USB COM UA02 4 USB IBM Table Top UA00 USB IBM Hand Held UA01 When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software which can...

Page 49: ...Network configurations The following parameter groups are common to all interface applications DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulatio...

Page 50: ...NG ACK NACK PROTOCOL FIFO INTER CHARACTER DELAY RX TIMEOUT SERIAL TRIGGER LOCK 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired gr...

Page 51: ...n Exit and Save Configuration RS 232 42 BAUD RATE 300 baud CD1X 600 baud 1200 baud CD2 CD3 2400 baud 4800 baud CD4a CD5d 9600 baud 19200 baud CD6g CD7j 38400 baud CD8m PARITY none CC0S even parity odd...

Page 52: ...ave Configuration RS 232 43 DATA BITS 7 bits CA0O 8 bits 9 bits CA1R CA2U STOP BITS 1 stop bit CB0Q 2 stop bits CB1T HANDSHAKING disable CE0W hardware RTS CTS software XON XOFF CE1Z CE2 RTS always ON...

Page 53: ...2 for details particularly on implementing this parameter with PowerScan M8300 FIFO disable EC0U enable EC1X See par 5 1 3 for details INTER CHARACTER DELAY delay between characters transmitted to Hos...

Page 54: ...UT disabled 01 99 TIMEOUT from 1 to 9 9 seconds rx timeout 5 seconds See par 5 1 4 for details SERIAL TRIGGER LOCK disabled CR0q enable and select characters CR1t Read 2 characters from the Hex Numeri...

Page 55: ...racter delay Inter code delay USB keyboard speed USB IBM No parameter selection required 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the...

Page 56: ...0W hardware RTS CTS software XON XOFF CE1Z CE2 RTS always ON CE3 See par 5 1 1 for details ACK NACK PROTOCOL disable ER0s enable ER1v See par 5 1 2 for details particularly on implementing this parame...

Page 57: ...T timeout control in reception from Host CL5 Read 2 numbers from the table where 00 TIMEOUT disabled 01 99 TIMEOUT from 1 to 9 9 seconds rx timeout 5 seconds See par 5 1 4 for details SERIAL TRIGGER L...

Page 58: ...ARD NATIONALITY Not Available for USB KBD ALT MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default Belgian FJ7y English UK French FJ4p F...

Page 59: ...tern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs Japanese FJ8 Russian Latin Russian Cyrillic FJ9 FJA0 Hungarian Slovenian Croatian Serbian Latin FJB3 FJC6 Romanian C...

Page 60: ...Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled INTER CODE DELAY delay between codes transmitted to Host FG Read 2 numbers from the...

Page 61: ...OCK INTER CHARACTER DELAY INTER CODE DELAY KEYBOARD SETTING WEDGE CONTROL CHARACTER EMULATION 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from...

Page 62: ...Enter Configuration Exit and Save Configuration WEDGE 53 KEYBOARD NATIONALITY Belgian FJ7y English UK French FJ4p FJ2j German Italian FJ3m FJ1g Spanish Swedish FJ6v FJ5s USA FJ0d...

Page 63: ...ungarian Slovenian Croatian Serbian Latin FJB3 FJC6 Romanian Czech Republic FJD9 FJE CAPS LOCK caps lock OFF FE0Z caps lock ON FE1 Select the appropriate code to match your keyboard caps lock status N...

Page 64: ...changes the way the Alt Mode procedure is executed therefore it should be set as follows if your keyboard Num Lock is normally on if your keyboard Num Lock is use num lock unchanged normally off use t...

Page 65: ...ultaneously during normal use refer to the manual of your PC or terminal for keyboard use The exact sequence must be indicated to the reader in this case pressing and releasing the different keys If o...

Page 66: ...bstituted with others corresponding to your keyboard The device signals the end of the procedure with 2 beeps indicating the keys have been registered 01 Shift 02 Alt 03 Ctrl 04 Backspace 05 SPACE 28...

Page 67: ...Enter Configuration Exit and Save Configuration WEDGE 58 CONTROL CHARACTER EMULATION Ctrl Shift Key FO0n Ctrl Key FO1q...

Page 68: ...IMUM OUTPUT PULSE CONVERSION TO CODE 39 OVERFLOW OUTPUT LEVEL IDLE LEVEL INTER BLOCK DELAY 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from th...

Page 69: ...e complete commands and do not require reading the Enter and Exit configuration codes OPERATING MODE interpret mode 8 Interprets commands without sending them to the decoder transparent mode 4 Sends c...

Page 70: ...Exit and Save Configuration PEN EMULATION 61 MINIMUM OUTPUT PULSE 200 s low resolution code emulation high resolution code emulation DG0 400 s 600 s DG1_ DG2b 800 s 1 ms DG3e DG4h 1 2 ms DG5k See par...

Page 71: ...onversion to Code 39 DA1S Converts codes read into Code 39 format See par 5 2 2 for details CONVERSION TO CODE 39 AND CODE 128 M8300 SERIES ONLY enable conversion to Code 39 DA1S Converts codes read i...

Page 72: ...logic level 1 See par 5 2 4 for details IDLE LEVEL normal DE0X black level inverted DE1 white level See par 5 2 4 for details INTER BLOCK DELAY delay between character blocks transmitted to Host CK3...

Page 73: ...E NETWORK WARNING MESSAGE RECEPTION WARNING MESSAGE MASTER CRADLE HEADER MASTER CRADLE TERMINATOR 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes...

Page 74: ...Z1 RZ2 See par 3 2 for details If a BC 8060 cradle is errantly configured as a Slave but not connected to a network it may not be able to receive further commands from the reader In this case it can b...

Page 75: ...ddress JC Read the code above and the four digit address of the Last Slave device in the system See par 5 3 1 for details NETWORK WARNING MESSAGE network warning message not transmitted JG0b network w...

Page 76: ...3 JA04 five character header six character header JA05C JA06G seven character header eight character header JA07K JA08O After selecting one of the desired Header codes read the character s from the HE...

Page 77: ...13 JA14B five character terminator six character terminator JA15F JA16J seven character terminator eight character terminator JA17N JA18R After selecting one of the desired Terminator codes read the c...

Page 78: ...TX CHARACTER REPLACEMENT ADDRESS STAMPING ADDRESS DELIMITER TIME STAMPING TIME DELIMITER 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the...

Page 79: ...SI M y Z Code 11 H y b Code 16K K 0 p Code 49 T y q GS1 DataBar Expanded Linear and Stacked e 0 t GS1 DataBar Limited e 0 v GS1 DataBar 14 Linear and Stacked e 0 u AIM standard identifiers are not def...

Page 80: ...e code type from the code table in Appendix B for the identifier you want to change You can define 1 or 2 identifier characters for each code type If only 1 identifier character is required the second...

Page 81: ...ader six character header EA05 EA06B seven character header eight character header EA07F EA08J After selecting one of the desired Header codes read the character s from the HEX table Valid characters...

Page 82: ...terminator six character terminator EA15A EA16E seven character terminator eight character terminator EA17I EA18M After selecting one of the desired Header codes read the character s from the HEX tab...

Page 83: ...Wedge IBM AT PS 2 and USB KBD Interfaces It is necessary to define each Special Key by following the procedure given in par 5 4 2 NOTE Select one or more of the following Special Keys according to yo...

Page 84: ...on right deletion 12 23 left deletion 34 Read a number in the range 01 32 from the Hex Numeric Table to define how many characters to add or delete Conditions Adjustment is only performed on the barco...

Page 85: ...Wedge and USB KBD interfaces it is also possible to read the Special Key s on page 74 To define the field adjustment character A Example Read field adjustment character 41 CODE LENGTH TX code length n...

Page 86: ...dix B read the Code Identifier for the desired code family 0 character replacement will be effective for all code families From the Hex Numeric Table read two characters corresponding to the Hex value...

Page 87: ...character first character replacement Code 39 ASCII characters corresponding to the HEX value for character 0 ASCII characters corresponding to the HEX value for character 1 EO1p VW 30 31 For Code 39...

Page 88: ...RU1 enable cradle address stamping RW1 See par 5 4 3 for details ADDRESS DELIMITER M8300 SERIES ONLY disable reader address delimiter RV0 disable cradle address delimiter enable reader address delimi...

Page 89: ...r minutes seconds month day year hour minutes seconds day month year IL1n hour minutes seconds month day year IL3t IL4w day month year IL5z See par 5 4 5 for details TIME STAMPING DELIMITER M8300 SERI...

Page 90: ...Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the procedure given Default value 3 Read the Exit and Save C...

Page 91: ...0 series readers sleep state is entered immediately after reading a code and is not configurable ENTER SLEEP TIMEOUT enter sleep timeout BR Read 2 numbers in the range 00 99 00 Enter Sleep state immed...

Page 92: ...EPER TYPE BEEPER LENGTH GOOD READ SPOT DURATION AIMING SYSTEM CRADLE BEEPER INTENSITY 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the des...

Page 93: ...TRIGGER TYPE hardware trigger BK1e Restores TRIGGER MODE software trigger always on BK0b Enables FLASH MODE BK3k TRIGGER SIGNAL trigger active level BA0N trigger active pulse BA1Q See par 5 6 1 for d...

Page 94: ...to a max 99 sec delay after the trigger press to allow the reader to turn off automatically trigger off timeout disabled See par 5 6 3 for details FLASH MODE FLASH ON duration BB0P FLASH OFF duration...

Page 95: ...at least 400 ms 01 99 timeout from 1 to 9 9 seconds before a consecutive read on same code safety time 0 5 sec See par 5 6 5 for details BEEPER INTENSITY very low intensity BG0Z low intensity medium i...

Page 96: ...Enter Configuration Exit and Save Configuration READING PARAMETERS 87 BEEPER TONE tone 1 BH0 tone 2 tone 3 BH1_ BH2b tone 4 BH3e BEEPER TYPE monotone BJ0 bitonal BJ1c BEEPER LENGTH long BI0 short BI1a...

Page 97: ...figuration READING PARAMETERS 88 GOOD READ SPOT DURATION disable BV0x short medium BV1 BV2 long BV3 AIMING SYSTEM disabled Bj09 enabled Bj1 CRADLE BEEPER INTENSITY disable JI0f low intensity medium in...

Page 98: ...efore changing these parameter values read the descriptions in par 5 7 CAUTION 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired gr...

Page 99: ...Configuration DECODING PARAMETERS 90 INK SPREAD disable AX0 enable AX1 See par 5 7 1 for details OVERFLOW CONTROL disable AW1 enable AW0y See par 5 7 2 for details INTERDIGIT CONTROL disable AV0w enab...

Page 100: ...ameter allows reading multiple parts of the single code to reconstruct it To read codes using this technology simply move the illuminated bar over the code so that each line of the code is scanned Dur...

Page 101: ...MSI CODE 11 CODE 16K CODE 49 GS1 DATABAR CODES 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow t...

Page 102: ...reading different codes belonging to the same family information about the last code will overwrite the information about the previous one Follow the given procedure to auto configure the desired cod...

Page 103: ...the number of CODES enabled to 10 as it depends on the code family NOTE SINGLE SELECTIONS Example 5 code selections 1 2 2 5 Interleaved 3 Code 128 EAN 128 2 5 Industrial 4 Code 39 Full ASCII Code 32 5...

Page 104: ...the EAN UPC without ADD ON code selection is enabled by default to correctly enable another selection first disable the family AA8e EAN 8 EAN 13 UPC A UPC E with and without ADD ON WITHOUT ADD ON EAN...

Page 105: ...PC A UPC E AAN WITH AND WITHOUT ADD ON EAN UPC with and without ADD ON no Autodiscrimination AA8Ad03 EAN UPC Autodiscrimination ADD ON by Prefix AA8Ad19 By setting the EAN UPC Autodiscrimination ADD O...

Page 106: ...ound the barcode will not be read Barcodes starting with different characters are read regardless of ADD ON presence and transmitted always without ADD ON ET0w Cancel All Selections OR select one or m...

Page 107: ...and transmission with ADD ON of all EAN UPC barcodes starting with 434 439 prefixes 3 977 enables reading and transmission with ADD ON of all EAN UPC barcodes starting with 977 prefix 4 978 enables re...

Page 108: ...AN UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION EAN 8 NO CHECK DIGIT TRANSMISSION AAG1o EAN 8 AAG0k EAN 13...

Page 109: ...TIONS UPC E to UPC A conversion AAA UPC E to EAN 13 conversion UPC A to EAN 13 conversion AAB AAC EAN 8 to EAN 13 conversion Enable only ISBN conversion AAD AP1n Enable only ISSN conversion Enable bot...

Page 110: ...digit control without transmission Matrix 2 5 3 Bars 34 AC4 Read 4 numbers for the code length where First 2 digits minimum code length Second 2 digits maximum code length The pharmaceutical code belo...

Page 111: ...e part of the Code 39 family but have no check digit selections Code CIP39 AB3X French pharmaceutical code Code 32 AB4 Italian pharmaceutical code CODE LENGTH optional The code length selection is val...

Page 112: ...cter can also be transmitted before the code disable EQ0q enable EQ1t If the GS character has been modified in the Character Replacement parameter the new character is affected by this command CODE LE...

Page 113: ...ssion of check digit CODABAR FAMILY disable the family AD0S Read the desired equality control code Read a start stop transmission selection START STOP CHARACTER TRANSMISSION Standard Codabar AD113 no...

Page 114: ...on is valid for the entire Codabar family Read the code 4 numbers for the code length where set code length First 2 digits minimum code length Second 2 digits maximum code length AD A The maximum code...

Page 115: ...trol AE1X MOD10 check digit control no check digit transmission AE2 MOD10 check digit control check digit transmission AE3 MOD11 MOD10 check digit control no check digit transmission AE4a MOD11 MOD10...

Page 116: ...ol AG1 Type C check digit control check digit transmitted AG21 Type C check digit control check digit not transmitted AG22 Type K check digit control check digit transmitted AG31 Type K check digit co...

Page 117: ...de so that each line of the code is scanned During this process a series of brief ticks indicates that reading is proceeding correctly CODE 49 disable the code AM0e AM1h Code 49 To read stacked codes...

Page 118: ...1 DataBar Expanded Linear and Stacked disable GS1 DataBar Limited AQ11M AQ20L enable GS1 DataBar Limited disable GS1 DataBar 14 Linear and Stacked AQ21P AQ30O enable GS1 DataBar 14 Linear and Stacked...

Page 119: ...atting parameters may not be compatible with the IBM USB POS interface selection NOTE 1 Read the Enter Configuration code ONCE available at the top of page 2 Read configuration codes precisely followi...

Page 120: ...ype and length It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires The order of transmission is CODE 1 CODE 2 Define Concatenation 1 Code...

Page 121: ...milies you must select the Code ID character of the resulting code The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection Datalogic A...

Page 122: ...ORMATTING 113 5 Transmission after Timeout no code transmitted after timeout EM0i only code 1 transmitted if read after timeout EM1l only code 2 transmitted if read after timeout EM2o either code 1 or...

Page 123: ...performed when the barcode data meets certain criteria which you will define in the following procedure Define another Enable Advanced Formats 1 2 3 4 Define No Match Result Read the Exit and Save Co...

Page 124: ...1W begin Format 3 definition HA2Z begin Format 4 definition HA3 2 Match Code Type match code type HB Read the above code the code type to match from the Code Identifier Table B in Appendix OR any code...

Page 125: ...e read the character s from the HEX table Range of characters 00 FE Example Match code with the 2 character predefined string Read Match with a 2 character string 40 40 AND position of first character...

Page 126: ...BY In this case you can choose to discard the code separator character or include it as the last character of the field b defining a match character to be found consecutively repeated in the code its...

Page 127: ...om the HEX table Range of characters 00 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 1 Termina...

Page 128: ...om the HEX table Range of characters 00 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 2 Termina...

Page 129: ...om the HEX table Range of characters 00 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 3 Termina...

Page 130: ...om the HEX table Range of characters 00 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 4 Termina...

Page 131: ...om the HEX table Range of characters 00 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 5 Termina...

Page 132: ...xed field HI3m 4 character fixed field HI4p 5 character fixed field HI5s 6 character fixed field HI6v After selecting one of the Additional Fixed Field codes read the corresponding character s from th...

Page 133: ...fixed field HJ3o 4 character fixed field HJ4r 5 character fixed field HJ5u 6 character fixed field HJ6x After selecting one of the Additional Fixed Field codes read the corresponding character s from...

Page 134: ...responding to the fields to transmit in the order in which they are to be transmitted A field can be transmitted more than once See example field 1 12 field 2 field 3 23 34 field 4 field 5 45 56 addit...

Page 135: ...ead Standard Formatting Headers Code Length Code ID Terminators can be applied to the message to be transmitted POWERSCAN M8300 After performing Advanced Formatting on the barcode read Standard Format...

Page 136: ...ED FORMATTING 127 Enable Advanced Format no Advanced Formats enabled HN0n Advanced Format 1 enable HN11N disable HN10J Advanced Format 2 enable HN21Q disable HN20M Advanced Format 3 enable HN31T disab...

Page 137: ...using standard format HO1s This selection determines the action to be taken when codes read do not conform to the advanced format requisites no match Codes not matching can be ignored cleared from me...

Page 138: ...N MODE BEEPER CONTROL FOR RADIO RESPONSE SINGLE STORE BATCH MODE FIND ME 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups R...

Page 139: ...om the table where 02 19 timeout from 2 to 19 seconds 2 seconds See par 5 9 1 for details RADIO RX TIMEOUT radio RX timeout disable always on Specify timeout Read 2 numbers in the range 05 99 05 99 Ra...

Page 140: ...EOUT power off timeout RPL Read 2 numbers in the range 00 99 00 Power off disabled reader always ready 01 99 corresponds to a max 99 hour delay before power off power off after 4 hours See par 5 9 3 f...

Page 141: ...Enter Configuration Exit and Save Configuration RADIO PARAMETERS 132 BEEPER CONTROL FOR RADIO RESPONSE normal BF0X only good decode only good reception BF1 BF2 off BF3a See par 5 9 5 for details...

Page 142: ...ration RADIO PARAMETERS 133 SINGLE STORE disable RO0z one attempt two attempts RO1 RO2 three attempts four attempts RO3 RO4 five attempts six attempts RO5 RO6 seven attempts eight attempts RO7 RO8 nin...

Page 143: ...enable normal batch BZ1 BZ2 See par 5 9 7 for details The following batch management parameters are complete commands and do not require reading the Enter and Exit configuration codes start normal ba...

Page 144: ...RAST FONT SIZE BACKLIGHT DISPLAY OFF TIMEOUT DISPLAY MODE KEYPAD 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the...

Page 145: ...SPLAY PARAMETERS DATE AND TIME set date IA set time Read 6 numbers for DDMMYY IB Read 4 numbers for HHMM CONTRAST lighter IC0Y darker IC1 Read the code until the desired contrast is reached FONT SIZE...

Page 146: ...LAY OFF TIMEOUT timeout IF Read 2 numbers in the range 00 99 00 disables display timeout always on 01 to 99 timeout from 1 to 99 seconds display off after 8 seconds delay disabled DISPLAY MODE normal...

Page 147: ...ERS 138 KEYPAD PARAMETERS KEYPAD disable 3 key keypad IK0i enable 3 key keypad and select characters IK1l Read 3 HEX characters in the range 00 FE corresponding to the left center and right keys respe...

Page 148: ...AY PARAMETERS DATA FORMAT OPERATIVE MODE QTY CODE MODE 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and f...

Page 149: ...a cell phone with multi tap access to alpha characters on numeric keys In alphabetic mode entered by toggling the Shift key the keys must be pressed once twice or more to obtain the desired letter See...

Page 150: ...hich shows in the display when active The default labels are shown in the table below To program the function key labels see Function Key Label command on page 143 The following table shows the list o...

Page 151: ...d 1 7 STRING TABLE The Powerscan 16 key model allows you to define a String Table a database with room for five entries from String1 to String5 which can be recalled using a Function Key This is done...

Page 152: ...e 141 NOTE Function key label length is fixed at 4 characters and is not programmable define function key label Read the above code Specify which Function Key Label you want to change by scanning a ba...

Page 153: ...is to toggle from numeric to alpha mode After the Shift Key has been defined as Function 5 refer to the Function Key Programming command on page 141 for options SHIFT KEY Normal mode SHIFT KEY Functi...

Page 154: ...time Read 6 numbers for DDMMYY IB Read 4 numbers for HHMM CONTRAST lighter IC0Y darker IC1 Read the code until the desired contrast is reached DISPLAY OFF TIMEOUT timeout IF Read 2 numbers in the ran...

Page 155: ...igurable timeout LAST CODE SHOWN TOUT NOTE Just as in the settings for the standard Powerscan the display has an active timeout before going in OFF state This timeout has a higher priority than the LA...

Page 156: ...rd disabled Display disabled keyboard enabled rarely used Display enabled keyboard enabled SCREEN REFRESH Disable screen refresh at the end of keyboard data input This feature works only in Simple Dat...

Page 157: ...ion for other formatting options NOTE if you enable different formatting you must define the desired format otherwise the default data format will be used See par 5 17 1 in the References section for...

Page 158: ...et the desired result HEADER no header one character header two character header three character header four character header five character header six character header seven character header eight ch...

Page 159: ...erminator seven character terminator eight character terminator After selecting one of the desired Header codes read the character s from the HEX table Valid characters are in the range 00 FE For Wedg...

Page 160: ...result HEADER no header one character header two character header three character header four character header five character header six character header seven character header eight character header...

Page 161: ...erminator seven character terminator eight character terminator After selecting one of the desired Header codes read the character s from the HEX table Valid characters are in the range 00 FE For Wedg...

Page 162: ...sable Datalogic standard AIM standard custom For more information on this feature see par 5 17 2 See also Message Formatting in par 6 1 and par 6 2 SCANNER CODE LENGTH This feature forces the scanner...

Page 163: ...r key is pressed following the formatting rules described in the previous paragraph QTY CODE Quantity Code Mode Refer to the next section QTY CODE MODE PARAMETERS Simple Data Input Mode Quantity Code...

Page 164: ...pad or read through the scanner The pair quantity and code are then transmitted to the host in a single string with configurable header terminators and separator Use the commands in the following sect...

Page 165: ...eding CODE field and its predefined format 1 code is transmitted with CODE field and its predefined format preceding QTY field and its predefined format 2 code in CODE field is sent out for the number...

Page 166: ...n CODE field is sent out for a QTY number of times See Qty Code Send Mode on the previous page The number of codes depends on the unit inserted via keypad by the user to cope with different use cases...

Page 167: ...th of the separator you want to insert by scanning a barcode 1 8 from the Hex Numeric table in the back of this manual Define the separator string using a sequence of four hex ascii codes from the tab...

Page 168: ...is written in the CODE field by keyboard and the code is transmitted 1 Barcode data is appended to any text in the CODE field and the code is transmitted 2 Barcode data is appended to any text in the...

Page 169: ...possible only if the CTS line controlled by the Host is active RTS CTS handshaking Software handshaking XON XOFF During transmission if the Host sends the XOFF character 13 Hex the decoder interrupts...

Page 170: ...must be disabled manually see par 5 1 3 PowerScan M8300 Readers The transmission protocol takes place between reader cradle and Host The reader passes its data code read to the cradle which sends it t...

Page 171: ...3 5 1 3 FIFO PowerScan D8330 Readers This parameter determines whether data barcodes are buffered on a First In First Out basis allowing faster data collection in certain cases for example when using...

Page 172: ...ical resolution of the code read The shortest pulse 200 s corresponds to a high resolution code emulation and therefore a shorter transfer speed to the decoder for decoders able to work on high resolu...

Page 173: ...pace 30 times the minimum output pulse 5 2 4 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation bar space white black barco...

Page 174: ...ddress range During this phase the yellow LED on the Master cradle blinks The time to complete the start up procedure varies depending on the complexity of the network but is typically between a few s...

Page 175: ...dard header terminator selection the Master cradle can add its own header terminator to the entire message sent to the Host In the STAR System network headers and terminators for all RF Devices are di...

Page 176: ...F6 F6 8B F7 F7 F7 F7 8C F8 F8 F8 F8 8D F9 F9 F9 F9 8E F10 F10 F10 F10 8F F11 ESC F11 F11 90 F12 BACKSPACE F12 F12 91 HOME HOME ENTER F13 92 END END RESET F14 93 PG UP PG UP INSERT F15 94 PG DOWN PG DO...

Page 177: ...cial Keys can be used for Headers Terminators Character Replacement Field Adjustment Custom Code ID Advanced Formatting Define Field Advanced Formatting Additional Fixed Field Follow the procedure to...

Page 178: ...REFERENCES 169 2 Read only one code to be associated with the special key sequence SHIFT 12 OR CTRL 23 OR ALT 45 OR CTRL SHIFT 34 OR ALT SHIFT 56 OR CTRL ALT 67...

Page 179: ...B 05B 025 S 025 S 025 S 025 A 025 S 02E S 02E S 052 S 052 S 02E S 02E S 02E S 02E S 02E S 036 S 03D S 016 016 036 S 03D S 036 S 036 S 036 S 04E 052 025 025 05D S 052 04E 05D 03D S 03E S 046 S 02E 02E...

Page 180: ...4 055 S 054 S a 01C 01C 015 015 01C 01C 01C 01C 01C b 032 032 032 032 032 032 032 032 032 c 021 021 021 021 021 021 021 021 021 d 023 023 023 023 023 023 023 023 023 e 024 024 024 024 024 024 024 024...

Page 181: ...the keyboard nationalities ITA USA FR BE DE UK ES SW JP ENTER 05A 05A 05A 05A 05A 05A 05A 05A 05A TAB 00D 00D 00D 00D 00D 00D 00D 00D 00D F1 005 005 005 005 005 005 005 005 005 F2 006 006 006 006 006...

Page 182: ...14 214 214 214 214 02E A 02E A 024 A 024 A 024 A 025 A 02E A 02E A SPACE 029 029 029 029 029 029 If Caps Lock Auto Recognition is disabled it is necessary to verify that the keyboard caps lock status...

Page 183: ...3 ALT Read FQ9E2F 45 codes from Appendix C corresponding to the character value for F6 exit save configuration 00B 4 the following example allows defining Special Key 4 as Alt Shift F1 enter configura...

Page 184: ...figuration two character terminator special key 4 ASCII characters corresponding to the HEX value for character ENTER Read EA125 9F 83 exit save configuration 5 4 3 Address Stamping It is possible to...

Page 185: ...r minimum power consumption For D series readers this command is only valid when hardware trigger type is selected Before entering Sleep mode the following are verified no commands coming from Host no...

Page 186: ...e 5 6 3 Trigger Off Timeout When this timeout is selected the reader turns OFF automatically after the desired period of time 5 6 4 Reads per Cycle In general a reading cycle corresponds to the ON OFF...

Page 187: ...ame code consecutive reading can be disabled requiring the reader to be removed from the code no decoding for at least 400 ms or a timeout can be set up to 9 9 seconds before the decoder will accept t...

Page 188: ...lowing the Format 1 To send the same code with the Format 2 it is necessary to invert the format order as follows Format 1 Match Code length 15 and Match with Predefined Characters DATA Format 2 Match...

Page 189: ...iver awake for a defined period of time following each transmission Any message coming from the host1 before expiration of the timeout is accepted The parameter Radio RX Timeout is used for specifying...

Page 190: ...ough the cradle with an answer message message to reader display or command to reader see par 6 3 and the following figure BC 80X0 Host data cable PowerScan M8300 data Transmission Mode Two Ways Host...

Page 191: ...essage There are applications in which there is no risk of transmission failure In such cases it may be better to disable single store so that the user perceives a more consistent behavior of the trig...

Page 192: ...for the Host answer message to be shown on the display Therefore in Two way transmission mode and normal batch mode the Start Normal Batch Transmission barcode must be read after each code to continue...

Page 193: ...lete previously inserted data The action of the function keys changes to reflect the different user mode It will be Function Key Action Label F1 toggles between INSERT MODE and SCROLL MODE Bat F2 Scro...

Page 194: ...splay After Decode mode When a barcode is read with the reader The code is sent to the Host The reader display is cleared There is no Local Echo of the code to the reader display Therefore if any prev...

Page 195: ...ce Guide for default settings K Transmit the PowerScan D8330 or PowerScan M8300 software release _ Transmit PowerScan reader configuration in ASCII format This command is not effective with Pen emulat...

Page 196: ...a particular state during which it reads and transmits to the Host information about the family type of codes unknown to the user with the exception of MSI Code 49 and Code 16k code types It is also p...

Page 197: ...talogic distributor to provide this connection RS 232 Cables Power Supply CAB471 CAB472 PG5 Using the slave reader read the Restore Default barcode and then the RS 232 interface barcode from chapter 4...

Page 198: ...X0 If this causes undesired effects disconnect the RS 232 cable between the PC and BC 80X0 during this process Copy Configuration ZZ0 With the slave PowerScan M8300 read the Get Configuration barcode...

Page 199: ...erface cables and external power supply Accessory cables and power supply are available from your Datalogic distributor to provide this connection RS 232 Cables Power Supply CAB471 CAB472 PG12 Read th...

Page 200: ...o Header No Header Terminator CR CR CR Field Adjustment Disabled Disabled Disabled Code Length TX Not Transmitted Not Transmitted Not Transmitted Character Replacement Disabled Disabled Disabled Addre...

Page 201: ...e setup file Procedure Connect the device to the PC via USB or serial connection RS 232 Launch Aladdin on your PC From the menu select Tools firmware upgrade Read the code below and position the reade...

Page 202: ...at Disabled Scanner Data Header Terminator not null Formatting is applied identically to a label read or data input from the keyboard as programmed with Scanner Data Header Terminator on page 146 Keyp...

Page 203: ...e from Disable option 1 2 3 Datalogic standard AIM standard or custom Use the specific DK Scanner Code ID instead of the standard Code ID DK Scanner Code ID will be applied and will take priority over...

Page 204: ...ckets are optional Output Message from PowerScan M8300 STAR System Time stamp Ts_delimiter Header Code ID Code Length CODE Terminator Towards Host Items in square brackets are optional For PowerScan M...

Page 205: ...Data Format section beginning on page 139 S Header The optional Header programmed from Display and Keypad Parameters It is additional to Header programmed from general Data Format It can be o Scanner...

Page 206: ...gth may also be programmed in the DK model C Header Scanner Addr Scanner Addr delimiter Cradle Addr Cradle Addr delimiter Time Stamp Time Stamp Delimiter S Header C ID C len CODE S Term C Term C Heade...

Page 207: ...ive messages if two way mode is enabled See par 5 9 4 Transmission Mode the command is on page 180 Messages cannot start with because they would be interpreted as a configuration command You can send...

Page 208: ...Therefore column 6 is 36 pixels from the left border only if you last selected the 6x8 font otherwise it could be 48 or 72 pixels from the left border 6 3 2 Font Selection ESC 0 m Normal mode ESC 7 m...

Page 209: ...LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper The LED and Beeper will be controlled by the system after the e...

Page 210: ...ter Cradle_Addr Cradle_Addr_delimiter Time stamp Ts_delimiter Code ID Code Length KeyID Terminator Items in square brackets are optional The messages are handled by the system as if they were barcodes...

Page 211: ...anually input data The 16 key keypad is organized like a cell phone with multi tap access to alpha characters on numeric keys Press the keys once twice or more to cycle through the alpha letters and s...

Page 212: ...SB KBD APPLE USB COM USB IBM Table Top USB IBM Hand Held Laser Features D8330 D8330 AR Light Source VLD between 630 680 nm Scan Rate 35 5 scans sec Power max in mW 0 9 mW 1 3 mW Scan Angle 42 13 5 0 7...

Page 213: ...ween 630 680 nm Scan Rate 35 5 scans sec Power max in mW 0 9 mW 1 3 mW Scan Angle 42 13 5 0 7 PCS minimum Datalogic Test Chart 15 25 Maximum Resolution 0 076 mm 3 mils 0 19 mm 7 5 mils Reading Field W...

Page 214: ...s M8300 DK M8300 DKAR Power max in mW 0 9 mW 1 3 mW Light Source VLD in the range between 630 680 nm Scan Rate 35 5 scans sec Reading Field Width typical see reading tables Max Resolution 0 076 mm 3 m...

Page 215: ...re 20 to 70 C 4 to 158 F Humidity 90 non condensing Drop resistance on concrete 2 m Protection Class IP64 Mechanical Features Weight with batteries about 400 g 14 10 oz Dimensions 212 x 109 x 71 mm 8...

Page 216: ...1xx 32xx 34xx 37xx terminals Wyse terminals Digital VT terminals Apple ADB Bus supported Not supported PEN Emulation Selectable minimum pulse from 200 S to 1 2 mS Not supported USB USB KBD USB KBD ALT...

Page 217: ...ICATORS The scanner has two indicator LEDs and a Beeper The BC 8000 and C 8000 cradles have four LED indicators three for BC 8010 model and a Beeper They signal several operating conditions which are...

Page 218: ...ity command can modify these signals The data entry good read tone is user configurable with all For M series readers normally this results in two beeps the first indicates that the reader has decoded...

Page 219: ...ing red green repetitive beep Charging out of temperature range over current or over voltage conditions Alternating red green every 30 seconds beep every 30 seconds Reader not correctly inserted onto...

Page 220: ...42 8 cm 1 1 16 8 in 13 2 3 55 1 cm 0 9 21 7 in 20 6 3 78 5 cm 2 5 30 9 in 40 2 5 97 8 cm 1 0 38 5 in POWERSCAN D8330 M8300 DK AR models mil Typical reading distance with good quality codes 7 5 18 50 c...

Page 221: ...configuration environment Exit and Save configuration Example Beeper tone 1 Beeper low intensity BG1 CR Carriage return character 0D Hex Exit and save new configuration AC410132 BH0 Matrix 2 5 3 bars...

Page 222: ...IBM Terminals 31xx 32xx 34xx 37xx make break keyboard CP501 for IBM Terminals 31xx 32xx 34xx 37xx make only keyboard CP502 Keyboard Type for IBM Terminals 31xx 32xx 34xx 37xx typewriter FK0 advanced...

Page 223: ...ing disable CE0 RTS CTS CE1 XON XOFF CE2 RTS always On CE3 ACK NACK Protocol disable ER0 enable ER1 FIFO disable EC0 enable EC1 Inter character Delay ms CK00 CK99 RX Timeout 100 ms CL00 CL99 Serial Tr...

Page 224: ...ODE English UK FJ4 French FJ2 German FJ3 Italian FJ1 Spanish FJ6 Swedish FJ5 USA FJ0 Keyboard Nationality Japanese FJ8 IBM AT compatible only Russian Latin FJ9 Russian Cyrillic FJA Hungarian FJB Slove...

Page 225: ...Recognition disable FP0 IBM AT compatible only enable FP1 Num Lock toggle num lock FL1 num lock unchanged FL0 Delays Inter Character ms CK00 CK99 Inter Code s FG00 FG99 Control Character Emulation Ct...

Page 226: ...rning Message not transmitted JG0 transmitted JG1 Transmission Warning not transmitted JH0 Message transmitted JH1 Master Header no header JA00 one character JA01x two characters JA02xx three characte...

Page 227: ...minators no terminator EA10 one character EA11x two characters EA12xx three characters EA13xxx four characters EA14xxxx five characters EA15xxxxx six characters EA16xxxxxx seven characters EA17xxxxxxx...

Page 228: ...ss delimiter and select character RV1h disable cradle address delimiter RY0 enable cradle address delimiter and select character RY1h Time Stamping disable IL0 hour minutes seconds month day year IL1...

Page 229: ...f Timeout s BD00 BD99 FLASH ON 100 ms BB001 BB099 FLASH OFF 100 ms BB101 BB199 Reads per Cycle one read BC0 multiple reads BC1 Safety Time 100 ms BE00 BE99 Beeper Intensity very low intensity BG0 low...

Page 230: ...hout ADD ON AA1 with ADD ON AA5 with and without ADD ON AA8 EAN 8 EAN 13 without ADD ON AA3 with ADD ON 2 ONLY AAK with ADD ON 5 ONLY AAL with ADD ON 2 AND 5 AA6 UPC A UPC E without ADD ON AA4 with AD...

Page 231: ...eaved 2 5 no check digit control AC11xxxx check digit control and transmission AC12xxxx check digit control without transmission AC13xxxx Normal 2 5 5 bars no check digit control AC21xxxx check digit...

Page 232: ...trol without transmission of check digit AI11 enable EAN 128 control without transmission of check digit AI21 Transmit GS before Code disable EQ0 enable EQ1 ISBT 128 enable ISBT 128 AI31 code length A...

Page 233: ...AQ11 disable GS1 DataBar Limited AQ20 enable GS1 DataBar Limited AQ21 disable GS1 DataBar Linear and Stacked AQ30 enable GS1 DataBar Linear and Stacked AQ31 RADIO PARAMETERS DESCRIPTION STRING Radio P...

Page 234: ...ecode IG2 Keypad disabled keys IK0 enable and select KeyID characters IK1bbb ddmmyy numbers from the Hex Numeric Table representing day month year hhmm numbers from the Hex Numeric Table representing...

Page 235: ...n characters IpcAbbbbbbbbbb Function Key Label IOcbbbb Lower Case Disable Lower Case Bn0 Enabled Lower Case Bn1 Shift Key Programming Shift Key Normal Mode Bo0 Shift Key Function 5 Bo1 Echo Full Keypa...

Page 236: ...r no header EV00 one character EV01b two characters EV02bb three characters EV03bbb four characters EV04bbbb five characters EV05bbbbb six characters EV06bbbbbb seven characters EV07bbbbbbb eight char...

Page 237: ...EW8bbbbbbbb Append Code Overwrite CODE and transmit Bm0 Append to CODE and transmit Bm1 Append to code don t transmit Bm2 ddmmyy numbers from the Hex Numeric Table representing day month year hhmm num...

Page 238: ...5 Interleaved NO 2 5 Industrial 2 5 normal 5 bars PQ OP 2 5 matrix 3 bars EAN 8 QR AB EAN 13 UPC A BC CD UPC E EAN 8 with 2 ADD ON DE JK EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON KL LM EAN 13 with 5 AD...

Page 239: ...0 M8300 DK 230 UPC A with 5 ADD ON GH UPC E with 2 ADD ON UPC E with 5 ADD ON HI IJ Code 39 Code 39 Full ASCII VW WX CODABAR ABC CODABAR RS ST Code 128 EAN 128 TU kl Code 93 CIP 39 UV YZ CIP HR Code 3...

Page 240: ...231 MSI Z Code 16K Code 11 pq bc Code 49 GS1 DATABAR Expanded Linear and Stacked qr tu GS1 DATABAR Limited GS1 DATABAR 14 Linear and Stacked vw uv...

Page 241: ...4 _ 5F VT 0B 5 35 60 FF 0C 6 36 a 61 CR 0D 7 37 b 62 SO 0E 8 38 c 63 SI 0F 9 39 d 64 DLE 10 3A e 65 DC1 11 3B f 66 DC2 12 3C g 67 DC3 13 3D h 68 DC4 14 3E i 69 NAK 15 3F j 6A SYN 16 40 k 6B ETB 17 A 4...

Page 242: ...F10 8E B8 E3 F11 8F B9 E4 F12 90 BA E5 HOME 91 BB E6 END 92 BC E7 Pg UP 93 BD E8 Pg Down 94 BE E9 95 BF EA 96 C0 EB 97 C1 EC 98 C2 ED ESC 99 C3 EE CTRL Right 9A C4 EF 9B C5 F0 9C C6 F1 9D C7 F2 9E C8...

Page 243: ...F10 8E B8 E3 F11 8F B9 E4 F12 90 BA E5 HOME 91 BB E6 END 92 BC E7 Pg UP 93 BD E8 Pg Down 94 BE E9 95 BF EA 96 C0 EB 97 C1 EC 98 C2 ED ESC 99 C3 EE CTRL Right 9A C4 EF 9B C5 F0 9C C6 F1 9D C7 F2 9E C8...

Page 244: ......

Page 245: ...an Datalogic Scanning KK Telephone 81 0 3 3491 6761 japan scanning datalogic com Latin America Datalogic Scanning Inc Telephone 305 591 3222 latinamerica scanning datalogic com Singapore Datalogic Sca...

Reviews: