background image

Service

English

Rev. 1.0.1 / 2018-12-19

Appliance

VideoNetBox III

Summary of Contents for SMAVIA VideoNetBox III

Page 1: ...Service English Rev 1 0 1 2018 12 19 Appliance VideoNetBox III...

Page 2: ...ss negligence of the manufacturer Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany www dallmeier com info dallmeier com All trademarks identified by are registeres trademarks of...

Page 3: ...ranty 8 3 3 Mainboard Battery 8 3 4 Approvals Certifications 8 4 Login 9 4 1 Local Login 9 4 2 Remote Login 11 5 Licenses 13 6 Update 14 6 1 Maintenance License 14 6 2 Implementation 15 7 Systemparame...

Page 4: ...ocuments Data Sheet Technical specifications and data for trained system integrators Commissioning Instructions for installation connection and commissioning for trained system integrators Service thi...

Page 5: ...lt in minor or moderate injury NOTICE NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations For reasons of clarity and readability various text format...

Page 6: ...ernal components may cause malfunctions damages and data loss and may result in the loss of warranty Modifications Do not make any modifications to the hardware or software that have not been tested a...

Page 7: ...horten the life of the units and may cause malfunc tions damages and data loss and may result in the loss of warranty Observe the specifications given in the technical data the operating condition req...

Page 8: ...hall apply 3 3 Mainboard Battery Important basic functions eg time and hardware settings can be obtained from a battery on the main board of the appliance If the battery is emptied after a certain tim...

Page 9: ...cumentation Commissioning It contains detailed instructions on mounting connection assignment and commissioning of the device 4 1 Local Login In order to access the configuration interface of the appl...

Page 10: ...SMAVIA Appliance www dallmeier com 10 The configuration interface is displayed Abb 4 2 Make the required settings see below Click Close in order to exit the configuration interface...

Page 11: ...cation Note the documentation Operation of the PService3 application Start PService3 Scan the network Select the required appliance Open the context menu with a right click Click NetConfig3 The connec...

Page 12: ...SMAVIA Appliance www dallmeier com 12 The configuration interface is displayed Abb 4 4 Make the required settings see below Click Close in order to exit the configuration interface...

Page 13: ...f a hardware extension in conjunction with a li cense code Open the License Code dialog via System Service Extensions Abb 5 1 Enter the license code Click OK in order to save the entry After the activ...

Page 14: ...An appliance is to be updated in the third year of operation with a newly released update In this case maintenance licenses for the year one free license and for the year two free license and year thr...

Page 15: ...unstable power supply or via the contact IN interface Open the Software Update dialog via System Service Software Update Abb 6 2 Select the storage medium as Source Download the available updates with...

Page 16: ...ording settings will be lost Open the System Parameters dialog via System System Parameters Default Abb 7 1 Click OK The default system parameters will be restored 7 2 Export Parameters The system par...

Page 17: ...t Parameters Secured or modified system parameters can be imported to restore the configuration of the SMAVIA Recording Server NOTICE Data loss System failure Inappropriate or incorrectly modified sys...

Page 18: ...e the detailed explanations in the dialog Click Search USB stick if required Select the required storage medium as a Source Select the relevant import option Finally click OK in order to start the imp...

Page 19: ...e hard disk drive 8 1 Identify All hard disks are easily accessible on the front side of the device First the defective hard disk drive must be identified using the Information dialog 8 1 1 Informatio...

Page 20: ...ly specified gross capacity GB The capacity of a new HDD must be the same as the capacity of the replaced HDD or larger NOTICE Possibility of data loss Always replace a defective HDD with a HDD from t...

Page 21: ...OTICE Data loss In order to prevent data loss and damage to property observe the proce dure described above Identify the defective hard disk drive as described above Unlock the HDD drawer unit with th...

Page 22: ...tive HDD with a HDD from the same production series with identical firmware Slide the holdings over the HDD in such a way that that the connections of the HDD are positioned at the rear side of the HD...

Page 23: ...SMAVIA Appliance www dallmeier com 23 Do not use any force Lock the HDD drawer unit with the key The new hard disk drive is initialized as described above...

Page 24: ...units Ensure that both supply lines are disconnected from the supply circuit CAUTION Danger of explosion if battery is incorrectly replaced Replace and discard the battery of the main board in accord...