DV**PTC*14

 SERIES AIR HANDLERS

IOD-4021K
06/2021

Only personnel that have been trained to install, adjust, service 

or repair (hereinafter, “service”) the equipment specified in 

this manual should service the equipment. The manufacturer 

will not be responsible for any injury or property damage 

arising from improper service or service procedures.  If you 

service this unit, you assume responsibility for any injury or 

property damage which may result.  In addition, in jurisdictions 

that require one or more licenses to service the equipment 

specified in this manual, only licensed personnel should service 

the equipment.  Improper installation, adjustment, servicing 

or repair of the equipment specified in this manual, or 

attempting to install, adjust, service or repair the equipment 

specified in this manual without proper training may result in 

product damage, property damage, personal injury or death.

INSTALLATION INSTRUCTIONS

www.daikincomfort.com

 

Our continuing commitment to quality products may mean a change in specifications without notice.

19001 Kermier Road Waller, TX 77484

Index

1    Important Safety Instructions ................................................................ 2

2    Shipping Inspection ............................................................................... 3

2.1  Parts ...............................................................................................

3

2.2  Handling ..........................................................................................

3

3  Codes & Regulations ............................................................................. 3

4  Replacement Parts ................................................................................. 3

5  Pre-Installation Considerations ............................................................ 3

5.1  Preparation .....................................................................................

3

5.2  System Matches .............................................................................

3

5.3  Interconnecting Tubing ...................................................................

4

5.4  Clearances ......................................................................................

4

5.5  Horizontal Applications ...................................................................

4

6    Installation Location ......................................................... 4

6.1  Upflow Installation ...........................................................................

4

6.2  Horizontal Left Installation ..............................................................

4

6.3  Downflow/Horizontal Right Installation ...........................................

4

7    Refrigerant Lines .................................................................................... 6

7.1  Tubing Size .....................................................................................

6

7.2  Tubing Preparation .........................................................................

6

7.3  Tubing Connections for TXV Models ..............................................

7

7.4  Thermal Expansion Valve System Adjustment ...............................

8

8    Condensate Drain Lines .................................................. 8

9    Ductwork ......................................................................... 10

9.1  Thermal Expansion Valve System Adjustment ......................................

10

10  Return Air Filters .................................................................................. 10

11  Electric Heat .......................................................................................... 10

12   Electrical and Control Wiring ..............................................................11

12.1  Building Electrical Service Inspection ..........................................

11

12.2  Wire Sizing ...................................................................................

11

12.3  Maximum Overcurrent Protection (MOP) ....................................

11

12.4  Electrical Connections – Supply Voltage ....................................

12

12.4.1  Air Handler Only (Non-Heat Kit Models) ..................................

12

12.4.2  Air Handler - Non-Circuit Breaker Heat Kits .............................

12

12.4.3  Air Handler With Circuit Breaker Heat Kit ................................

12

12.5  Low Voltage Connections ...........................................................

12

13    Achieving 1.4% and 2.0% Airflow Low Leakage Rate

 ......................11

14    Start-Up Procedure ............................................................................. 12

15    Regular Maintenance ......................................................................... 12

16    Circulator Blower ................................................................................ 15

17    Troubleshooting ................................................................................. 17

 ©

 2014 - 2021

If  an “Ec” error is encountered on

startup, verify that the electric heater

DIP  switches  have  been  set  to  the

appropriate heater size.  See pages

14-17  for  the  heater  kit 

airflo

w

delivery and DIP switch 

se�ngs.

NOTICE

Summary of Contents for DV PTC 14 Series

Page 1: ...ations 3 4 Replacement Parts 3 5 Pre Installation Considerations 3 5 1 Preparation 3 5 2 System Matches 3 5 3 Interconnecting Tubing 4 5 4 Clearances 4 5 5 Horizontal Applications 4 6 Installation Loc...

Page 2: ...E Disconnect ALL power before servicing or installing this unit Multiple power sources may be present Failure to do so may cause property damage personal injury or death This product is factory shippe...

Page 3: ...g at the cabinet corners 3 Codes Regulations This product is designed and manufactured to comply with applicable national codes Installation in accordance with such codes and or prevailing local codes...

Page 4: ...hat may become wet such as crawl spaces elevate the unit with a sturdy non porous material In installations that may lead to physical damage i e a garage it is advised to install a protective barrier...

Page 5: ...CB14 DV33PTCC14 DV61PTCD14 DV39PTCC14 DV49PTCC14 DFK C DFK D Downflow Kit Downflow Kit Downflow Kit MODEL LIST FOR DOWNFLOW KITS DFK B Downflow Kit Table 2 Refer to Figure 6 and 7 for the location of...

Page 6: ...Center Support Filter Bracket Filter Access Panel INTERNAL PART TERMINOLOGY Figure 6 Blower Access Panel Coil Access Panel Tubing Panel UV Knockout EXTERNAL PART TERMINOLOGY Figure 7 NOTE If removing...

Page 7: ...t be proportional to the size of the tube Service personnel must use the appropriate heat level for the size of the tube being brazed CAUTION NOTE Refrigerant tubing must be routed to allow adequate a...

Page 8: ...superheat is low adjust TXV valve to 7 to 9 superheat and remove charge to lower the subcooling to 7 to 9 F NOTE Do NOT adjust the charge based on suction pressure unless there is a gross undercharge...

Page 9: ...per field constructed P style trap than is shown in Figure 12 to allow proper drainage and prevent condensate overflow Air Handler 2 75 MIN POSITIVE LIQUID SEAL REQUIRED AT TRAP Drain Connection 2 MIN...

Page 10: ...nit s Serial and Rating plate or the HKS specification sheets to determine the heat kits compatible with a given air handler No other accessory heat kit besides the HKS series may be installed in thes...

Page 11: ...your unit FIRE HAZARD To avoid the risk of property damage personal injury or fire use only copper conductors CAUTION HIGH VOLTAGE Failure to do so may cause property damage personal injury or death D...

Page 12: ...of the cabinet or either side See the Thermostat Wiring section of this manual for typical low voltage wiring connections 13 Achieving 1 4 and 2 0 Airflow Low Leakage Rate Ensure all the gaskets rema...

Page 13: ...ween Y1 and O for Proper Dehumidification Operation and Proper Ramping Profile Operation W2 Typical Single Stage Cooling with Single Stage Heating Figure 14 Air Handler Integrated Control Module Typic...

Page 14: ...CH Figure 19 Legacy mode use In a legacy system Non communicating this feature is not operational Any auxiliary alarm switch must be used to interrupt the Y1 signal either to the indoor or outdoor uni...

Page 15: ...flow for the cooling system Most cooling systems are designed to work with airflows between 350 and 450 CFM per ton Most manufacturers recommend an airflow of about 400 CFM per ton Example 2 5 tons X...

Page 16: ...R NR NR NR NR NR 1750 NR 25 OFF OFF OFF NR NR NR NR NR NR NR NR NR NR NR 1750 NR Note Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation Within...

Page 17: ...s maximum airflow capability is 2000 CFM and 25 continuous fan speed is selected the continuous fan speed will be 0 25 x 2000 CFM 500 CFM 6 The multi speed circulator blower also offers several custo...

Page 18: ...code from being displayed NOTE For installations not indicated in the preceding Temperature Rise Tables the following formula is to be used TR kW x 3412 x Voltage Correction 1 08 x CFM Where TR Tempe...

Page 19: ...ypically do not return information to the thermostat On the other hand the indoor unit outdoor unit and thermostat comprising a Communicating system communicate digitally with one another It is now a...

Page 20: ...to terminal 1 on indoor unit and thermostat and data line terminal 2 from AC HP must connect to terminal 2 on indoor unit and thermostat Verify wires are not reversed ATTENTION INSTALLER IMPORTANT NO...

Page 21: ...led when necessary and pitched to allow for drainage Drain pan and drain tubing has been leak checked Return and supply ducts are sealed Unit is elevated when installed in a garage or where flammable...

Page 22: ...a 1 data 2 wires Check wire connections at terminal block Verify air handler installation type noncommunicating traditional or communicating Check data 1 data 2 voltages Turn power OFF prior to repair...

Page 23: ...tory NOTE Consecutively repeated faults are shown a maximum of 3 times Submenu Item Model Number MOD NUM Displays the modular blower model number Serial Number SER NUM Displays the modular blower seri...

Page 24: ...ENT TRIP OR LOST ROTOR b5 BLOWER MOTOR ROTOR LOCKED b6 OVER UNDER VOLTAGE TRIP OR OVER TEMPERATURE TRIP b7 INCOMPLETE PARAMETER SENT TO MOTOR b9 LOW INDOOR AIRFLOW C1 LOW STAGE COOL LEGACY MODE ONLY C...

Page 25: ...ROL LOW VOLTAGE 24V FIELD SPLICE INTERNAL TO FIELD GRND OVERCURRENT BK BLACK OR ORANGE BL BLUE PK PINK GY GRAY RD RED WH WHITE PU PURPLE YL YELLOW BR BROWN COLOR CODES GN GREEN NOTES 1 PLACE RED WIRES...

Page 26: ...ERVICING MULTIPLE POWER SOURCES MAY BE PRESENT FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE PERSONAL INJURY OR DEATH WARNING Wiring is subject to change Always refer to the wiring diagram on the unit fo...

Page 27: ...uminum tube and fin evaporator coils Even a one time application of these corrosive chemicals can cause premature aluminum evaporator coil failure Any cleaners that contain corrosive chemicals includi...

Page 28: ...F WB F Heating Supply AirTemperature DB F Temperature Rise DB F DeltaT Difference between Supply and Return Temperatures DB F AirHandler Coil InverterMatched INVERTERAH COILONLY Check EEV and EEV wiri...

Page 29: ...29 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 30: ...30 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 31: ...31 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 32: ...register by following this link https daikincomfort com owner support product registration You can also scan the QR code on the right to be directed to the Product Registration page CUSTOMER FEEDBACK...