manualshive.com logo in svg
background image

User reference guide 

Daikin Altherma 3 M

EBLA04E

V3

EBLA06E

V3

EBLA08E

V3

EBLA04E

3V3

EBLA06E

3V3

EBLA08E

3V3

EDLA04E

V3

EDLA06E

V3

EDLA08E

V3

EDLA04E

3V3

EDLA06E

3V3

EDLA08E

3V3

= 1, 2, 3, …, 9, A, B, C, …, Z

= , , 1, 2, 3, …, 9

Содержание Altherma 3 M EBLA04E V3 Series

Страница 1: ...ser reference guide Daikin Altherma 3 M EBLA04E V3 EBLA06E V3 EBLA08E V3 EBLA04E 3V3 EBLA06E 3V3 EBLA08E 3V3 EDLA04E V3 EDLA06E V3 EDLA08E V3 EDLA04E 3V3 EDLA06E 3V3 EDLA08E 3V3 1 2 3 9 A B C Z 1 2 3...

Страница 2: ...5 6 4 To change the desired room temperature 28 5 6 5 To change the desired leaving water temperature 29 5 7 Domestic hot water control 30 5 7 1 About domestic hot water control 30 5 7 2 Reheat mode 3...

Страница 3: ...ltherma 3 M 4P685231 1A 2023 05 8 6 Symptom The system is making gurgling noises after commissioning 59 9 Relocation 61 9 1 Overview Relocation 61 10 Disposal 62 11 Glossary 63 12 Installer settings T...

Страница 4: ...Quick guide for basic usage Format Paper in the box of the outdoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital f...

Страница 5: ...e help button The breadcrumbs appear in the top left corner of the screen 2 To disable the breadcrumbs Press the help button again This document also mentions these breadcrumbs Example 1 Go to 4 3 Spa...

Страница 6: ...es a situation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the in...

Страница 7: ...educed physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the h...

Страница 8: ...NOT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible...

Страница 9: ...ventilate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Air...

Страница 10: ...ble models INFORMATION If underfloor heating is installed in the main zone then in cooling mode the main zone can only provide refreshment Real cooling is then NOT allowed 3 1 Components in a typical...

Страница 11: ...se through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code...

Страница 12: ...k Off On C 2 2 Set operation to On or Off To change the desired room temperature During room temperature control you can use the room temperature setpoint screen to read out and adjust the desired roo...

Страница 13: ...D curve Additional zone Cooling 3 6 Additional zone Cooling WD curve 2 Change the weather dependent curve There are 2 types of WD curves slope offset curve default and 2 points curve If needed you can...

Страница 14: ...d set offset Confirm changes and return to the submenu 2 points curve Y1 Y2 X1 X2 X1 X2 Outdoor ambient temperature Y1 Y2 Desired leaving water temperature Possible actions on this screen Go through t...

Страница 15: ...to On or Off To change the tank temperature setpoint In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank...

Страница 16: ...ctor With a USB memory stick the installer can Update the software This requires a correct config file on the USB memory stick Import the settings generated by E Configurator Heating Solutions Navigat...

Страница 17: ...Confirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home screen d Help button Press to show a help text related to...

Страница 18: ...t Mode Schedule Level Restrictions 7 4 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 4 Space heating cooling Operation mode Operation mode schedule Room comfort se...

Страница 19: ...Screen with weather dependent curve c4 Screen with schedule 5 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint tem...

Страница 20: ...t pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is cu...

Страница 21: ...pe Underfloor heating Fancoil unit Radiator i3 21 Measured room temperature a i4 35 Leaving water temperature setpoint a j Holiday mode Holiday mode active k Additional zone k1 Installed room thermost...

Страница 22: ...uman Comfort Interface BRC1HHDA used as room thermostat is controlling the outdoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving...

Страница 23: ...configuring the ONECTA app 5 3 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature screen 21 C 1 Room 2 M...

Страница 24: ...ours 11 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and proceed...

Страница 25: ...l and external room thermostat control the protection is NOT guaranteed NOTICE Water pipe freeze prevention Even if you turn OFF space heating cooling operation C 2 Operation Space heating cooling wat...

Страница 26: ...l return mode 8 7 About Version information about the system 8 8 Connection status Information about the connection status of the unit the room thermostat and WLAN 8 9 Running hours Running hours of s...

Страница 27: ...is in heating mode the icon is shown When the unit is in cooling mode the icon is shown The status indicator shows if the unit is currently in operation When the unit is not in operation the status in...

Страница 28: ...you are using method 2 You can see on the home screen which temperature control you are using 6 22 19 55 21 35 45 a2 a1 b 18 Feb 2020 a1 Heat emitter of the main zone in this example Underfloor heatin...

Страница 29: ...occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 5 6 5 To change the desired leaving water...

Страница 30: ...one of the following 2 1 Main zone Schedule 3 1 Additional zone Schedule 2 Select No To enable weather dependent operation for the leaving water temperature See 5 9 4 Using weather dependent curves 44...

Страница 31: ...or the tank the tank temperature is determined automatically by the outdoor temperature For more information see 5 9 Weather dependent curve 444 To determine which domestic hot water mode you are usin...

Страница 32: ...7 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank temperature is the same as the temperature of the domestic water entering the DHW tank example 15 C A...

Страница 33: ...view the setpoint screen but not modify it Instead you can modify the settings for the Comfort setpoint 5 2 Eco setpoint 5 3 and Reheat setpoint 5 4 When weather dependent operation is used for the ta...

Страница 34: ...lues one time then reuse the values in other screens such as the scheduling screen If you later want to change the value you only have to do it in one place Possible preset values You can set the foll...

Страница 35: ...defined schedules You can Consult which schedule is currently selected Schedule Control in Possible schedules 435 Select another schedule if needed To select which schedule you currently want to use 4...

Страница 36: ...chedules 3 Activation screen 1 1 Schedule Possible actions Temperatures within range 1 3 Room Cooling schedule Schedule for the desired room temperature in cooling mode Predefined schedules 1 Activati...

Страница 37: ...e for your normal domestic hot water needs Predefined schedules 1 Activation screen Not applicable This schedule is automatically activated if the DHW mode is one of the following Schedule only Schedu...

Страница 38: ...oster heater operation allowed 5 8 3 Schedule screen Example This example shows how to set a room temperature schedule in heating mode for the main zone INFORMATION The procedures to program other sch...

Страница 39: ...Sat Wed Fri Thu Tue Sun User defined 1 2 Select Delete Delete Rename Select 3 Select OK to confirm To clear the content of a day schedule 1 Select the day of which you want to clear the content For ex...

Страница 40: ...lear an action set its time as the time of the previous action 4 Confirm the changes Result The schedule for Monday is defined The value of the last action is valid until the next programmed action In...

Страница 41: ...is action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule for Saturday and copy it to Sunday 1 Select Saturday 2 Select Edit 3 Use the left dial to select a...

Страница 42: ...5 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed Usage example You work in a 3 shift system If you work in a 3 shift system you can do the following 1 Program 3 room te...

Страница 43: ...electricity supplier 3 Confirm the changes INFORMATION The values correspond with the electricity price values for High Medium and Low previously set If no schedule is set the electricity price for H...

Страница 44: ...operates weather dependent if the desired leaving water or tank temperature is determined automatically by the outdoor temperature It therefore is connected to a temperature sensor on the North wall o...

Страница 45: ...See 5 9 4 Using weather dependent curves 447 Availability The weather dependent curve is available for Main zone Heating Main zone Cooling Additional zone Heating Additional zone Cooling Tank only ava...

Страница 46: ...nd offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water for different ambient temperatures For ex...

Страница 47: ...one heating Main zone or additional zone cooling Domestic hot water X1 X2 Examples of outdoor ambient temperature Y1 Y2 Y3 Y4 Examples of desired tank temperature or leaving water temperature The icon...

Страница 48: ...nge the type for all zones main additional and for the tank go to 2 E Main zone WD curve type Viewing which type is selected is also possible via 3 C Additional zone WD curve type 5 E Tank WD curve ty...

Страница 49: ...oor temperatures Slope Offset OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot To fine tune the weather dependent curve 2 points curve The following table describes how to fine tune t...

Страница 50: ...estriction Only possible if enabled by the installer 1 Go to 7 4 2 User settings Quiet Schedule 2 Program the schedule Possible actions You can use the following system defined preset values Off Quiet...

Страница 51: ...Confirm the changes 3 Set the last day of your holiday Go to 7 3 3 Till Select a date Confirm the changes 5 10 4 Using WLAN INFORMATION Restriction WLAN settings are only visible when a WLAN cartridg...

Страница 52: ...ay Mode 2 In the Enable AP mode screen select Yes D 2 Reboot Reboot the WLAN cartridge 1 Go to D 2 Wireless gateway Reboot 2 In the Reboot the gateway screen select OK D 3 WPS Connect the WLAN cartrid...

Страница 53: ...on User reference guide 53 EBLA04 08E2V3 E23V3 EDLA04 08E2V3 E23V3 Daikin Altherma 3 M 4P685231 1A 2023 05 1 Go to D 6 Wireless gateway Cloud connection 2 Read out the connection status Not connected...

Страница 54: ...when you are leaving for a couple of hours For longer periods You can use the holiday mode Tips about leaving water temperature In heating mode a lower desired leaving water temperature results in low...

Страница 55: ...orinated greenhouse gases requires that the refrigerant charge of the unit is indicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the re...

Страница 56: ...23V3 Daikin Altherma 3 M 4P685231 1A 2023 05 WARNING Do NOT pierce or burn refrigerant cycle parts Do NOT use cleaning materials or means to accelerate the defrosting process other than those recommen...

Страница 57: ...n case of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the le...

Страница 58: ...heat emitter type See 5 6 5 To change the desired leaving water temperature 429 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 5 9 Weather dependent curve 444 8...

Страница 59: ...ting is reduced but domestic hot water is still available auto SH reduced DHW off space heating is reduced and domestic hot water is NOT available auto SH normal DHW off space heating operates as norm...

Страница 60: ...ith the air purge function of the unit to be performed by the installer If you purge air from the heat emitters or collectors mind the following WARNING Air purging heat emitters or collectors Before...

Страница 61: ...08E2V3 E23V3 Daikin Altherma 3 M 4P685231 1A 2023 05 9 Relocation 9 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact helpdesk number v...

Страница 62: ...3 M 4P685231 1A 2023 05 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislatio...

Страница 63: ...r domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application exp...

Страница 64: ...estic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Glycol Filled system overview field setting E 0D Booster heater capacity 9 4 1 if applicable Bivalent 9 C Backup heater Voltage 9 3 2 Configurat...

Страница 65: ...Altherma 3 M 4P685231 1A 2023 05 Setting Fill in Heat up mode 5 6 Comfort setpoint 5 2 Eco setpoint 5 3 Reheat setpoint 5 4 Setpoint mode 5 B WD curve type 5 E read only 12 2 Settings menu Setting Fi...

Страница 66: ......

Страница 67: ......

Страница 68: ...4P685231 1A 2023 05 Copyright 2022 Daikin Verantwortung f r Energie und Umwelt...

Отзывы: