background image

Man274 (20 May. 2016)

                                                                              Smart Vacuum Ovens

.

Certifications by 

- - -

ISO 9001 Certified.
ISO 13485 Certified 
UL/CUL Certified
CE Certified
PL Insurance. 
Validation(IQ&OQ) Service.

User Manual

(Version : 2.2.2)

written for

ThermoStable

TM

SOV-20/-30/-70 models

ThermoStable

TM

“SOV-30”

Smart Vacuum Oven, 30Lit

.

DAIHAN-Sci.com or 

ALL

for

LAB.com

Shopping Mall

Sales & Basic A/S :

By the Nearest Official Distributors.

²

English Page : P. 

1

1 ~ 43

²

Korean Page : P. 44 ~ 86

Summary of Contents for ThermoStable SOV-20

Page 1: ...CE Certified PL Insurance Validation IQ OQ Service User Manual Version 2 2 2 written for ThermoStableTM SOV 20 30 70 models ThermoStableTM SOV 30 Smart Vacuum Oven 30Lit DAIHAN Sci com or ALL for LAB...

Page 2: ...DAIHAN Sci com or ALL forLAB com Shopping Mall DAIHAN Scientific Smart Vacuum Oven 2 67...

Page 3: ...Product Configuration 6 2 Installation 2 1 Product Installation 7 2 2 Installation of WiReTM App Web Service 10 2 3 Product Specifications 16 3 Product Usage 3 1 Product Usage 17 3 2 Names of Each Par...

Page 4: ...g Failure to follow the instructions may result in injury Caution Failure to follow the instructions may result in product failure Proximity Caution Keep clear of the product during use Notification D...

Page 5: ...realize high thermal conductivity by adopting the High Heat Conduction Mechanism which optimizes the thermal conductivity in the vacuum condition without the thermal conductivity by air 3 Because the...

Page 6: ...20 30 70 1 unit Standard Shelf Aluminum 2 ea Including a copy of the Operation Manual Model ThermoStableTM OV 20 Precise Vacuum Ovens 18 6Liter ThermoStableTM OV 30 Precise Vacuum Ovens 30 Liter Therm...

Page 7: ...peration at a rated voltage so please check the voltage status before installing the product 7 When installing and using the product please certainly use the power cord provided with the products Inst...

Page 8: ...tickers Attached to side of product For meaning of each symbol please refer to Precautions Before Use Safety Instructions Product Liability PL Insurance Admission DAIHAN Scientific Co Ltd is a member...

Page 9: ...m Pump can be often scattered together the heat of the de saturated gas For this reason because the life of Vacuum Pump can be shortened user must protect the Vacuum Pump by cooling the de saturated g...

Page 10: ...ed when shipped This describes how to install WiReTM Service It only describes items that must be installed to use WiReTM Service Please refer to How to use page for more product operation details It...

Page 11: ...h the date time box on the right If you randomly change the current time since supplied from the factory please be sure to use after re applying power to the equipment If you have changed the time of...

Page 12: ...he previous page if the blue return icon on the top right is clicked 2 Wifi Setup Set WiReTM Service is possible to use only if connected to internet Be sure to connect to a wireless LAN Connect to Wi...

Page 13: ...on is stable WiRe Mode is not possible if WiFi is not connected or network is unstable Make sure the network is stable It is possible to check Serial Number Model and Organization Name at below after...

Page 14: ...ID must be entered in at least more than 6 and less than 20 lowercase alphabetic characters and digits In cases of duplicate ID or less than 6 or more than 20 places other than lowercase uppercase al...

Page 15: ...onitor the status of device User can not remotely control After selecting an ID that wants to change authority from the registered user list set and select from Admin or User Since only one Admin is a...

Page 16: ...n TFT LCD Smart Lab Controller Controller Smart Lab Controller Resolution Control 1 0 Display 1 0 Shelves 2ea of Aluminum Shelves Included detachable Shelves Size W x D 260 X 245mm 290 X 285mm 340 X 3...

Page 17: ...ress the power cord Please do not hurt on the power cord or process it or force bend it or pull it and tie it Also if heavy objects are placed over the power cord or the power cord is inserted in betw...

Page 18: ...and can get rained on it is prohibited It may cause overheating or electrical fault of the product Please do not use flammable or volatile products in the vicinity of the product to minimize the risk...

Page 19: ...set at a well ventilated place Be sure the holes on the side or rear surface of the body are blocked by a wall or an object And do not operate the device at a poor ventilated place or use closed It ma...

Page 20: ...y Vacuum Gauge If user set up the vacuum indicate the vacuum level of the inside while the needle of gauge moves from the right to the left Controller Set and Check operation Door Handle Door Open and...

Page 21: ...OFF Vacuum Control Valve Open Close for Vacuum State using Vacuum Pump Connection Vent Control Valve Air Inflow Controller within Chamber when releasing Vacuum Vent Nozzle Air Inflow Nozzle when rele...

Page 22: ...amber before performing the operation of the product 3 Check the Vent Control Valve in the vacuum control unit of the oven and close it by completely turning clockwise 4 Open the Vacuum Control Valve...

Page 23: ...the vacuum state after that the experiment is completed open the Vent Valve by turning it counterclockwise The quantity of inflow air at the time of the vacuum release can be adjusted according to the...

Page 24: ...perations OFF SET Set compensating temperature values CHART Monitors operational status in graph SETTINGS Sets various functions of device Error Notifies device s error WiFi connectivity Indicates int...

Page 25: ...etup screen by pressing SET button on the right where the set temperature is shown You can set the temperature at a 1 increment and can set between 25 to 230 Press ENTER after entering the set tempera...

Page 26: ...ing Mode After Power Failure It sets a mode for power is abruptly cut off and turned back up due to power supply issues such as power outage When setting a Stop mode It stands ready at the value prior...

Page 27: ...operates at a temperature set that it previously operated on and the operation time on main screen continues its counting B Program Mode It restarts the count from the remaining time of first segment...

Page 28: ...Set Fixed Operation Time Mode to ON and press Fixed Operation Time to set the value of timer It operates for a time it set when you start the product from main screen If Fixed Operation Time Mode is...

Page 29: ...t temperature after setting the segment time to reach the target temperature If the maintaining time for target temperature is not needed do not make second segment for the target temperature B Normal...

Page 30: ...as Serial Number Model Temp Range and a version of Touch App Security Settings 1 Key Lock It requests password to access some key menu settings in menu Key Lock is activated by setting button to the...

Page 31: ...store up to 120 and a maximum of 100 segments can be stored in 1 Pattern Pattern is created by using button and in case you want to delete press the number of Pattern you want to delete and verify the...

Page 32: ...er the value of Segment after creating Pattern and Segment You can verify the temperature and time set for the Segment selected when you select Segment from the Segment window and touch You can reset...

Page 33: ...he operation of Program Mode 1 Program button it enters into the Program setting screen rapidly 2 Step button It skips to next Segment while in operation 3 Hold button It temporarily stops while in op...

Page 34: ...can be set to infinity by pressing button at 1 2 You can edit the order of operation after setting the number of repeat Select Start Segment and End Segment by pressing button from Sequence list and s...

Page 35: ...ct from stored Pattern other than selected Pattern with Repeat operation it does not allow to operation in continuation of other Pattern after the Repeat operation if set to None Wait In operation of...

Page 36: ...l memories at every 10 seconds and maximum 6 months of data are stored Please use Data Backup once every 6 months Temperature scope shown on graph can be changed using the set button on the low left M...

Page 37: ...the point detailed information of the location emerges on a detail display You can check the information on graph by moving at a small increment of the point using arrows on the detail display The ar...

Page 38: ...s ON OFF button 3 3 5 Error Message Wait screen shows a warning Error in case of failure and it shows which Error it is if you press the icon Touch Screen is rebooted when the reset button is pressed...

Page 39: ...C 3 If not being used for a long period unplug and dry before packaging for storage 4 If replacement parts are required due to the failures while in use it must use the original parts supplied by the...

Page 40: ...rent temperature of product when slowly turning clockwise up to 320 after adjusting the Safety Knob to 0 4 Tak sound is Normal If Tak sound is not occurred A S is required 5 Please check the progress...

Page 41: ...sition and if SAFETY Knob is in the 0 position sets up 30 40 higher than the service temperature Heating but unit not reaching temperature Check the Set Temperature is higher than ambient temperature...

Page 42: ...uminum OVS020 w295xd285xh98mm for 18 6 Lit DH WOV11030 Standard Shelf Aluminum OVS030 w295xd285xh98mm for 30 Lit DH WOV11070 Standard Shelf Aluminum OVS070 w395xd395xh130mm for 70 Lit Validation lQ OQ...

Page 43: ...rument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This certification is only for international c...