background image

PLANNING

GUIDE

www.Dacor.com

Phone: (800) 793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

4.18

A

30” and 36” Wide, Distinctive Series 

Slide-in Gas Cooktops

DRT304S, DRT366S

ELECTRIC CIRCUIT REQUIREMENTS

Circuit Required

Total Connected Load

120 Vac 60Hz, 15 Amp. (3 wire)

0.25 Amp @ 120 Vac, 60 Hz

GAS SUPPLY PRESSURE REQUIREMENTS*

Gas Type

Manifold Pressure

Minimum Gas Supply 

Pressure

Natural Gas

5” Water Column

6” Water Column

Propane (LP)

10” Water Column

11” Water Column

* Maximum gas supply pressure for all models is 1/2 p.s.i.

Installation of a non-combustible material* (up to the hood) or 

a backsplash is always recommended, and mandatory if the 

distance to the back wall from the cooktop is less than 2 1/2” 

(Figure 2). When installing a backguard, use only Dacor model 

numbers AEB3009, AEB3012 (DRT304S), AEB3609 or AEB3612 

(DRT366S).

SIDE VIEw wIthoUt BAckGUArD

SIDE VIEw wIthoUt BAckGUArD

SIDE VIEw

Product Dimensions

Electrical and Gas Supply Requirements

Cabinet and Countertop Layout

COOKTOP WIDTH (A)

DRT304S

29 7/8” (759 mm)

DRT366S

35 7/8” (911 mm)

Product tolerances: 

±1/16” (±1.6 mm) 

unless otherwise noted

 WARNING

Observe all governing codes and ordinances during 

◊ 

planning and installation. Contact your local building 

department for further information. 
This appliance must be installed in accordance with the 

◊ 

accompanying installation instructions.

Document # PG04-003

Revised 06/22/09   Page 1/3

4” (102 mm)

5/8” Min. 

(16 mm)

7 3/4”

 (197 mm)

Trim:

1/2”

 (13 mm)

thick

25 7/8” (657 mm)

1 5/8” (41 mm) cooking surface 

height (grate level) above 

countertop

3/4” gas inlet, connects to regulator from 

bottom or rear of unit, end is recessed 

2” (51 mm) from chassis bottom

28 1/8” (714 mm)

Power cord

32” long

Combustible

rear wall

Backguard mandatory if

gap from back of cooktop

to combustible wall is less

than 2 1/2”

Combustible

rear wall

2 1/2” (64 mm) Min. to

combustible rear wall

Reviews: