background image

 

               
 
 
 

 

 

 

 

 

CP750LCD/CP750LCDM 

User’s Manual 

K01-0000121-01 

 

 

 

(SAVE THESE INSTRUCTIONS) 

This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. 

Read this manual thoroughly before attempting to unpack, install, or operate your UPS. 

CAUTION!   

To  prevent  the  risk  of  fire  or  electric  shock,  install  in  a  temperature  and  humidity  controlled  indoor  area  free  of  conductive 

contaminants.    (Please see specifications for acceptable temperature and humidity range). 

CAUTION!   

To reduce the risk of electric shock, do not remove the cover. There are no user serviceable parts inside. 

CAUTION!   

Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. 

CAUTION!   

The

 

UPS must be connected to an AC power outlet with fuse or circuit breaker protection.    Do not plug into an outlet that is not 

grounded.    If you need to de-energize this equipment, turn off and unplug the unit. 

CAUTION!   

To avoid electric shock, turn off the unit and unplug it from the AC power source before installing a computer component. 

CAUTION!

    Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, 

ANSI/NFPA 75. 

CAUTION!

    To  reduce  the  risk  of  fire,  connect  only  to  a  circuit  provided  with  20  amperes  maximum  branch  circuit over  current  protection in 

accordance with the National Electric Code, ANSI/NFPA 70. 

CAUTION!   

Risk of explosion if battery is replaced by an incorrect type. Batteries shall be installed by service personnel, and the replacement of 

batteries with a suitable recommended type. Dispose of used batteries according to the instructions.

 

CAUTION!   

Do not dispose of batteries in a fire. The batteries may explode. 

CAUTION!   

Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.

 

DO  NOT  USE  FOR  MEDICAL  OR  LIFE  SUPPORT  EQUIPMENT!   

CyberPower  Systems  does  not  sell  products  for  life  support  or  medical 

applications.   

DO NOT

 use in any circumstance that would affect operation and safety of life support equipment, any medical applications or 

patient care. 

DO NOT USE WITH OR NEAR AQUARIUMS!   

To reduce the risk of fire or electric shock, do not use with or near an aquarium.

   

Condensation 

from the aquarium can cause the unit to short out. 
 

 

 

 

UNPACKING 

Inspect the UPS upon receipt. The box should contain the following: 

(a) UPS unit (b) User’s manual (c) PowerPanel

®

 Personal Edition software CD 

(d) USB device cable (e) Telephone cable (f) Warranty registration card 
 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT

 

1.

  Ensure that the equipment plugged into the outlet does not exceed the UPS unit’s rated capacity (750VA/420W for

 

CP750LCD/CP750LCDM).   

If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to 

trip.     

2.

  There are many factors that can affect the amount of power that your computer system will require.    For optimal system performance keep 

the load below 80% of the unit’s rated capacity. 

 

HARDWARE INSTALLATION GUIDE 

1.  Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to   

ensure the battery’s maximum charge capacity, it is recommended that you charge the battery   

for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is   

plugged into an AC outlet, the battery will automatically charge when it’s turned on or turned off. 

2.  With the UPS unit turned off and unplugged, connect your computer, monitor, and any other 

 

peripherals requiring battery backup from the SURGE/BATTERY outlets.    Plug the other peripheral equipment (eg. printer, scanner, 

speakers, etc.) into the full-time surge protection outlets. 

DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, 

sump pump, or other large electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices 

will overload and possibly damage the unit. 

3.  To protect a fax, phone, or modem, connect a telephone cable from the wall jack outlet to the IN jack   

of the UPS. Connect a telephone cable from one of the UPS OUT jacks to the modem port on the computer.   

The other UPS OUT jack can be used to protect a telephone or fax machine. 

4.  Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet).    Make sure the wall branch outlet is   

protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air   

conditioner, refrigerator, copier, etc.).    The warranty prohibits the use of extension cords, outlet strips,   

and surge strips. 

5.  Press the power switch to turn the unit on.    The Power On indicator light will illuminate green and the unit will “beep” twice. 

6.  If an overload is detected, an audible alarm will sound and the unit will emit one long beep.    To correct this, turn the UPS off and unplug at 

least one piece of equipment from the battery power supplied outlets.    Make sure the circuit breaker is depressed and then turn the UPS on. 

7.  To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

8.  To store the UPS for an extended period, cover it and store with the battery fully charged.    While in storage, recharge the battery every three 

months to ensure optimal battery life. 

9.  Insure the wall outlet and UPS are located near the equipment being attached for proper accessibility. 

 

 

 

 

DESCRIPTION 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

Battery and Surge Protected Outlets 

The unit has four battery powered/surge suppression outlets to ensure temporary uninterrupted operation of your equipment during a power 

failure. 

(DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum, sump pump, or other large electrical device 

into the “Battery and Surge Protected Outlets.” The power demands of these devices will overload and possibly damage the unit.) 

    

Full-Time Surge Protection Outlets 

The unit has four surge suppression outlets. 

    

Power Switch 

Press the power button to turn the UPS on or off. 

    

Power On Indicator (green) 

This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes. 

    

Electrical Wiring Fault Indicator (red) 

This LED indicator will illuminate to warn the user that a wiring problem exists, such as bad ground, missing ground or reversed wiring.    If 

this is illuminated, disconnect all electrical equipment from the outlet and have an electrician verify the outlet is properly wired. The unit will 

not provide surge protection without being plugged into a grounded and properly wired wall outlet. 

    

Communication Protection Ports 

Communication protection ports will protect any standard modem, fax, or telephone line. (RJ11) 

    

Circuit Breaker 

Located on the side of the UPS, the circuit breaker serves to provide overload and fault protection.   

    

USB Port to PC 

The USB port allows connection and communication between the USB port on the computer and the UPS unit.    The UPS communicates its 

status to the PowerPanel

®

 Personal Edition software.    The USB interface is also compatible with the Power Management applications 

provided by Windows 7, Vista, Mac OS X, and Linux. 

    

Outlets Designed for AC Adapters 

The UPS unit has four widely-spaced outlets, so AC power adapters can be plugged into the UPS without overlapping adjacent outlets. 

 

 

 

 

INPUT voltage meter: 

This meter measures the AC voltage that the UPS system is receiving from the 

utility  wall  outlet.  The  UPS  is  designed  to  continuously  supply  connected  equipment  with  stable, 

110/120 output voltage. In the event of a complete power loss, severe brownout, or over-voltage, the 

UPS  relies  on  its  internal  battery  to  supply  consistent  110/120  output  voltage.  The  INPUT  voltage 

meter can be used as a diagnostic tool to identify poor-quality input power. 

OUTPUT voltage meter:

 This meter  measures, in real time, the AC voltage that the UPS system is 

providing to the computer during normal AC/Utility Power mode, and battery backup mode. 

ESTIMATE  RUN  TIME: 

This  displays  the  run  time  estimate  of  the  UPS  with  the  current  battery 

capacity and load. 

NORMAL icon

: This icon appears when the UPS is working under normal conditions. 

BATTERY icon

: During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate 

the UPS is operating from its internal battery. During a prolonged brownout or blackout, the alarm will sound continuously. The BATT.CAPACITY 

meter will show one 20% capacity segment remaining to indicate the UPS's battery is nearly out of power. You should save files and turn off your 

equipment immediately. 

OVER LOAD icon

: This icon appears and an alarm sounds to indicate the battery-supplied outlets are overloaded. To clear the overload, unplug 

some of your equipment from the battery-supplied outlets until the icon turns off and the alarm stops. 

BATT. CAPACITY meter

: This meter displays the approximate charge level of the UPS's internal battery in 20% increments. During a blackout 

or severe brownout, the UPS switches to battery power (the BATTERY icon appears) and the battery charge level decreases. 

LOAD CAPACITY meter

: This meter displays the approximate output load level of the UPS battery outlets in 20% increments.

 

 

AC/Utility Mode

 

Select SW 

Press 

UPS Status Display 

Capacity Display 

Digital Value Display 

 

 

 

 

Load 
Cap. 

Battery 

Cap. 

Input 

Voltage 

Output 

Voltage 

Run 

Time 

of Load 

of Batt. 

Initial 

-- 

 

 

 

 

1st 

-- 

 

 

 

 

2nd 

-- 

 

 

 

 

3rd 

-- 

 

 

 

 

4th 

-- 

 

 

 

 

5th(Return) 

-- 

 

 

 

 

(Overload) 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

“V” : light up,        “X” : go out,        “--“ : not available

 

 

Battery mode 

“V” : light up,        “X” : go out,        “--“ : not available

 

 

 

 

 

 

Problem

 

Possible Cause 

Solution

 

Full-time surge protection outlets 
stop providing power to 
equipment. Circuit breaker 
button is projecting from the side 
of the unit.

 

Circuit breaker has tripped due to an 
overload. 

Turn the UPS off and unplug at least one piece of 
equipment.    Wait 10 seconds, reset the circuit breaker by 
depressing the button, and then turn the UPS on.

 

The UPS does not perform 
expected runtime. 

Battery not fully charged. 

Recharge the battery by leaving the UPS plugged in. 

Battery is worn out. 

Contact CyberPower Systems about replacement batteries 
at 

[email protected]

 

The UPS will not turn on. 

The on/off switch is designed to 
prevent damage from rapidly turning 
it off and on. 

Turn the UPS off.    Wait 10 seconds and then turn the UPS 
on. 

The unit is not connected to an AC 
outlet. 

The unit must be connected to a 110/120V 50/60Hz outlet. 

The battery is worn out. 

Contact CyberPower Systems about replacement batteries 
at 

[email protected]

 

Mechanical problem. 

Contact CyberPower Systems at 

[email protected]

 

Select SW 

Press 

UPS Status Display 

Capacity Display 

Digital Value Display 

 

 

 

 

Load 

Cap. 

Battery 

Cap. 

Input 

Voltage 

Output 

Voltage 

Run 

Time 

of Load 

of Batt. 

Initial 

-- 

-- 

 

 

 

 

1st 

-- 

-- 

 

 

 

 

2nd 

-- 

-- 

 

 

 

 

3rd 

-- 

-- 

 

 

 

 

4th 

-- 

-- 

 

 

 

 

5th(Return) 

-- 

-- 

 

 

 

 

Press >3sec 

(Sound 

Disable) 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

Press >3sec 

again 

(Sound Enable) 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

(Overload) 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

BASIC OPERATION 

INSTALLING YOUR UPS SYSTEM 

TROUBLESHOOTING 

IMPORTANT SAFETY WARNINGS 

 

 

 

DEFINITIONS FOR ILLUMINATED LCD INDICATORS 

The LCD display indicates a variety 

of UPS operational conditions. All 

descriptions apply when the UPS is 

plugged into an AC outlet and turned 

on or when the UPS is on battery. 

Reviews: