background image

AGM 55 

COMBUSTIBLE 

GAS LEAK 

DETECTOR 

 

 

 

OPERATING 

INSTRUCTIONS 

 

Crowcon Detection Instruments 

172 Brook Drive, 

Milton Park,

 

Abingdon, 

Oxfordshire OX14 4SD 

 

Tel: 01235 557780 

email: [email protected]

 

web: www.antonbycrowcon.com 

 

 

 

 

 

 

1. Gas intensity scale, yellow/orange/red indicating 

increasing gas intensity. 

2. Green power LED indicating the unit is switched on. 

This LED flashes when the batteries need 
replacing. 

3. Red LED gas intensity indicator. Flashes in unison 

with the buzzer (visual indication). 

4. Gas intensity buzzer. Sounds more frequently with 

increasing gas intensity (audible indication). 

5. Power Switch. Press and hold for 0.5s to turn on. 

Press and hold for 2s to turn off. 

6. DOWN Switch. Press and hold to decrease 

sensitivity. 

7. UP Switch. Press and hold to increase sensitivity. 

 

 

 

 

 
8. Gas sensor open to ambient air but protected by the 

head enclosure. 

9. 

White LED ‘search light’ for illuminating the source 
of the gas leak. 

 

SPECIFICATIONS 

Power Supply 

3 x AA Alkaline Batteries 

Battery Life 

> 1500 x 1 minute readings* 

Duty Cycle 

Continuous.  

Auto switch off after 5 mins. 

Sensor 

Solid State 

Sensitivity 

10 ppm methane 

Warm Up Time 

About 30 seconds 

Response Time 

Immediate 

Operating 
Temperature 

-10 to +50 °C 

Weight 

400 grams including 
batteries 

Dimensions 

185 x 75 x 37 mm (Body) 

425 mm (Probe length) 

 
* Using recommended Industrial batteries 
 

 

Reviews: