The Crestron

®

 CSA-PWS10S-HUB power supply powers up to 10 Crestron shades and features a built-in 5-segment 

Cresnet

®

 hub with network diagnostics capabilities. Local controls and indicators allow for easy testing of shades 

without connecting to a control system.  
The power supply is convection cooled for silent operation and can be surface mounted as a standalone device 

(CSA-PWS10S-HUB). It is also available for order in an enclosure (CSA-PWS10S-HUB-CAEN-1X1), which can 

be surface or flush wall mounted. 

CSA-PWS10S-HUB Specifications 

SPECIFICATION 

DETAILS 

Load Rating 

 

 

Total Shades Supported 

Provides power for up to (10) Crestron shades, each homerun to the power 

supply 

 

Output 

24 Vdc 

50 W per output LPS 

350 W total continuous load 

425 W for 2 minute on 2 minute off discontinuous shade load 

 

Load Protection 

(10) Self resetting thermal fuses and (10) 4 A time lag fuses, Littelfuse JDYX2 

0213 004 MXP (5 x 20 mm, 250 V, 4 A, time lag, cartridge) provided for each 

50 W segment, (1) of each per output 

Power Requirements 

120—240 Vac, 50/60 Hz;  

5 A maximum 

Environmental 

 

 

Installation Location 

Indoor use only 

 

Temperature 

32º to 104º F (0º to 40º C) 

 

Humidity 

10% to 90% RH (non-condensing) 

Enclosure 
 

CSA-PWS10S-HUB 

 

CSA-PWS10S-HUB-

CAEN-1X1 

 
Metal, gr

a

y, surface mount (indoor use only) 

Includes CAEN-1X1, 16 gauge galvanized steel enclosure with vented gr

a

y steel 

cover, surface mount or recessed in a wall (indoor use only) 

Dimensions 
 

CSA-PWS10S-HUB 

 

 

Height 

 

 

Width 

 

 

Depth 

 

CSA-PWS10S-HUB-

CAEN-1X1 

 

 

Height 

 

 

Width 

 

 

Depth 

 
 
7 9/16 in (194 mm) 
12 15/16 in (330 mm) 
2 11/16 in (68 mm) 
 

 

 
16 9/16 in (421 mm) 
16 1/8 in (409 mm) 
4 7/16 in (113 mm) 

Weight 
 

 CSA-PWS10S-HUB 

 

 CSA-PWS10S-HUB-

CAEN1x1 

 
5.6 lb (2.6 kg) 
15.0 lb (6.8 kg) 

(Continued on the following page) 

 

 

 

Summary of Contents for CSA-PWS10S-HUB

Page 1: ...des each homerun to the power supply Output 24 Vdc 50 W per output LPS 350 W total continuous load 425 W for 2 minute on 2 minute off discontinuous shade load Load Protection 10 Self resetting thermal fuses and 10 4 A time lag fuses Littelfuse JDYX2 0213 004 MXP 5 x 20 mm 250 V 4 A time lag cartridge provided for each 50 W segment 1 of each per output Power Requirements 120 240 Vac 50 60 Hz 5 A ma...

Page 2: ...to these connections Cresnet power output ports with data pass through In event of power failure the unit is auxiliary powered from this port to provide status A E 1 10 10 4 pin 5 mm detachable terminal blocks comprising 2 Cresnet ports per each of 5 hub segments Each terminal bock provides 24 volts and 50 watts LPS USB 1 USB Type B female USB computer console port LEDs PWR 1 10 10 Green LEDs indi...

Page 3: ...sted and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio ...

Page 4: ...de DOC 7438A CSA PWS10S HUB CAEN 1X1 Overall Dimensions Top and Front Views 1 1 4 in 32 mm 1 1 2 in 39 mm 5 11 16 in 145 mm 2 1 2 in 64 mm 1 5 16 in 33 mm 2 5 16 in 58 mm 4x Ø 1 3 4 in 45 mm Knockouts for 1 1 4 in 32 mm Conduit 2 9 16 in 65 mm 5 8 in 16 mm 15 16 in 24 mm 1 1 4 in 32 mm 1 1 4 in 32 mm 16 1 8 in 409 mm 16 9 16 in 421 mm ...

Page 5: ...upply for Crestron Shade Motors CSA PWS10S HUB 5 CSA PWS10S HUB CAEN 1X1 Overall Dimensions Bottom View 21x Ø 7 8 in 23 mm Knockouts for 1 2 in 13 mm Conduit 1 1 4 in 32 mm Typ 5 8 in 16 mm 15 16 in 24 mm 2 1 2 in 64 mm 3 13 16 in 97 mm 11 1 4 in 286 mm 14 3 8 in 365 mm 1 1 4 in 32 mm 1 1 4 in 32 mm ...

Page 6: ...B Installation Guide DOC 7438A CSA PWS10S HUB CAEN 1X1 Overall Dimensions Side View 1 in 26 mm 1 3 4 in 45 mm 8x Ø 3 16 in 5 mm Mounting Holes for 8 Wood Screws Not Supplied 2 1 2 in 64 mm 5 7 16 in 138 mm 1 7 16 in 36 mm 10 13 16 in 275 mm 15 13 16 in 402 mm 8 in 203 mm 2 1 4 in 58 mm 4 1 4 in 108 mm 4 7 16 in 113 mm ...

Page 7: ...ng Holes for 8 Wood Screws and 8 Large Flat Washers Not Supplied Cresnet connectors are included Cable Tie Anchors 2 3 4 in 70 mm 9 7 8 in 251 mm I T E POWER SUPP LY 41JC ASSEMBLED IN COO CSA PWS10S HUB CAEN 1X1 PN 6506320 SNXXXXX 000 00 INPU T 120 240 V 50 60 Hz 5A MAX OUTPU T 24V 350W CONTINUOUS 425W2MIN ON 2MIN OFF LIMITED DU TY C YCLE 50WMAX OUTPUT LPS I T E POWER SUPP LY 41JC ASSEMBLED IN COO...

Page 8: ...Ø3 16 in 5 mm Mounting Holes for 8 Pan Head Wood Screws Not Supplied Barcode Label for Power Supply All Cresnet connectors and fuses are included 2 1 4 in 58 mm IEC 3 Conductor Male Cable Aprox 10 254 mm Long 12 3 8 in 314 mm 7 9 16 in 194 mm 6 in 153 mm 5 16 in 9 mm 12 3 8 in 314 mm 2 7 16 in 63 mm 3 1 16 in 79 mm I T E POWER SUPP LY 41JC ASSEMBLED IN COO CSA PWS10S HUB INPU T 120 240 V 50 60 Hz ...

Page 9: ...TE Enclosure and power supply are intended for indoor use only NOTE When flush mounting 5 8 drywall is preferred NOTE Four keyholes are located within the enclosure and should be used if surface mounting Mounting the CSA PWS10S HUB CAEN 1X1 For surface mounting the enclosure must be mounted securely to building wall studs or at least 1 4 in 7 mm plywood using four 8 screws with four 8 large flat w...

Page 10: ...o prevent damage to low voltage wiring The device must be mounted before operation Class 1 and Class 2 field wires must be kept separate Refer to the following illustrations showing wiring details Areas for high voltage Class 1 wiring are along the left side of the unit The right side of the enclosure is reserved for low voltage Class 2 wiring NOTE The installer must provide disconnect means withi...

Page 11: ...expected If this situation occurs rearrange the loads between the two power feeds to evenly distribute the power draw Maximum Wire Runs The cable length between the motor and power supply is limited by voltage drop along the cable The following limits should be observed for reliable performance NOTE Wiring must be home run from the power supply to each shade motor Maximum total length of Cresnet c...

Page 12: ...t to 24 V may be reported as a short to GND on long cable runs NOTE A false short Y to Z may be reported if a termination resistor is implemented on Cresnet Cresnet does not require termination resistors NOTE Not all broken wire conditions can be detected A broken wire can only be detected in situations where there is intermittent communication The MSG LED also blinks to indicate an error situatio...

Page 13: ...ox help file for details There is a single method of communication USB The COMPUTER port on the CSA PWS10S HUB connects to the USB port on the PC via the included Type A to Type B USB cable 1 Click Tools System Info 2 Click the icon 3 For Connection Type select USB When multiple USB devices are connected identify the CSA PWS10S HUB by entering CSA PWS10S HUB in the Model text box the unit s serial...

Page 14: ...S HUB Installation Guide DOC 7438A Program Checks For Cresnet connections using Crestron Toolbox display the network device tree Tools Network Device Tree View to show all network devices connected to the control system Right click on the CSA PWS10S HUB to display actions that can be performed on the CSA PWS10S HUB ...

Page 15: ... drawing 20 watts should not have a length of run more than 333 feet 101 meters If Cresnet HP is used for the same run its length could extend to 1250 feet 381 meters NOTE All Crestron certified Cresnet wiring must consist of two twisted pairs One twisted pair is the 24 and G pair and the other twisted pair is the Y and Z pair Strip and Tin Wire Strip the ends of the power supply wires carefully t...

Page 16: ...arding the nature and extent of the dealer s warranty if any Crestron shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misuse accidental damage modification or improper installation procedures Furthermore this warranty does not cover any product that has had the serial nu...

Reviews: