background image

 
 

Crestron 

C2N-SPWS300  

System Power Supply 
Operations Guide

 

 

 

Summary of Contents for C2N-SPWS300

Page 1: ...Crestron C2N SPWS300 System Power Supply Operations Guide ...

Page 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2003 Crestron Electronics Inc ...

Page 3: ... Mounting 11 Hardware Hookup 11 Programming Software 14 C2Net Device Slot in Configuration Manager 15 Setting the Net ID in Device Settings 15 C2N SPWS300 Symbol in Programming Manager 16 Example Program 18 Uploading and Upgrading 19 Communication Settings 19 Uploading a SIMPL Windows Program 21 Firmware Upgrade 23 Problem Solving 25 Troubleshooting 25 Further Inquiries 26 Future Updates 26 Return...

Page 4: ......

Page 5: ...r Each output connector also has Cresnet Y Z signals All Cresnet signals are in parallel Functional Summary NOTE If all eight channels provide the maximum rating 75W the unit would have to supply 600 watts total That exceeds the C2N SPWS300 s 300W capability Therefore a channel can deliver up to 75W but every channel may not be fully utilized Some channels may not be used at all Channel Versus Sys...

Page 6: ...ion 24 VDC must be applied across the outer two pins 24 and G of the NET connector located in the upper right corner to enable the internal supply Once enabled the green LEDs illuminate successively as power is applied to each channel 1 through 8 until all eight channels are powered up When the power switch is in this position 24 VDC from the Cresnet network is used to activate a relay which in tu...

Page 7: ...date File CEN CN TVAV Update File Version 2 004 CUZ or later Version 5 12 63X UPZ or later Version 5 12 63W UPZ or later Version 4 02 4S UPZ or later Version 5 12 63V UPZ or later C2N SPWS300 Firmware C2N SPWS300 v1 3 upg or later Rack Space Required 3U high 1U wide Operating Temperature 41 to 104 F 5 to 40 C Humidity 10 to 90 RH non condensing Dimensions Height 5 19 in 13 18 cm Width 13 25 in 33 ...

Page 8: ...een designed to mount horizontally on its back in a rack cabinet or on a wall At the shorter sides of the unit the enclosure extends at a right angle to provide mounting flanges equipped with screw holes hardware supplied by others C2N SPWS300 System Power Supply Ports With the exception of the IEC320 connector on a pigtail cord for application of AC power all connections to the C2N SPWS300 are ma...

Page 9: ...ceeds the nominal 75 watts for any channel A system wide red LED OVLD illuminates when the full 300 watts 12 5 amps of the C2N SPWS300 is exceeded Pushbuttons A pushbutton RESET associated with each channel allows the user to reset the circuit breaker for each channel and turn on that channel Power is restored to an overloaded channel if the excess load has been removed from the channel or the cha...

Page 10: ... determine the number of C2N SPWS300s necessary to power all Cresnet components in a particular Cresnet system the total system power requirement must be calculated This is accomplished by adding the power requirements of all system components Refer to the leading specifications of each component for individual power requirements The total system power requirements should include the control syste...

Page 11: ...quation to calculate the value on the right side of the equation Resistance Equation R Resistance refer to table below L Length of run or chain in feet PF Power factor of entire run or chain R L x PF 40 000 Where The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation Refer to the table after this paragraph Wire Gauge Val...

Page 12: ...s Method A Cresnet address settable ID described below requires that a single C2N SPWS300 be the only network device connected to the control system This method is necessary with a CNX control system or with a 2 Series control system upgrade file CUZ version prior to 3 008 It is optional with later versions of the operating system Method B Touch Settable IDs which begins on the next page applies t...

Page 13: ...ch Settable IDs Before using this method you should have a list of all current network devices and their Net IDs to avoid assigning duplicate IDs Set Net ID by TSID These procedures are for TSID enabled network devices during the initial configuration of a Cresnet system or when such devices are being added replaced 1 Ensure that all C2N SPWS300s are connected to the control system 2 Open the Cres...

Page 14: ...etting duplicate IDs Be sure to check current assignments before entering the desired Cresnet ID number Serial Number to TSID Conversion This utility is useful in a case where there are multiple devices of the same type on a network you need to locate a particular one you know the TSID but not the serial number and your site installation list is based on device serial numbers In this or the revers...

Page 15: ...n the power supply approaches its maximum temperature rating consider using forced air ventilation or implementing additional supplies to distribute the load NOTE Utilize the signals available from the C2N SPWS300 SIMPL Windows symbol to track the internal temperature of the power supply Hookup Preparation Prior to making hardware connections it is assumed that all wiring is run and terminated wit...

Page 16: ...NSPWS300 OR CNPWS 75 HOME RUN METHOD NET Z Y G 24 NETWORK UNIT Z Y NET G 24 C2N SPWS300 NC 24 Z Y NET Y NET 24 G G Z EXPANSION POWER SUPPLY NC 24 Z Y Y 24 G G Z 24 Z Y Y 24 G G Z NETWORK UNIT CONTROL SYSTEM NETWORK UNIT ONLY CONNECT 24 VDC IF THE CONTROL SYSTEM DOES NOT EMPLOY AN INTERNAL POWER SUPPLY NOTE Never connect multiple C2N SPWS300s in parallel NOTE Always disconnect AC power to the C2N S...

Page 17: ...N POWER SUPPLY NC 24 Z Y Y 24 G G Z NETWORK UNIT NETWORK UNIT NETWORK UNIT HOME RUN METHOD NETWORK UNIT Z Y NET G 24 24 Z Y Y 24 G G Z CONTROL SYSTEM Z Y NET G 24 NET 24 Y Z G Hookup Procedure 1 Connect each network unit to the appropriate network connector 2 Connect AC power to the C2N SPWS300 3 If a PC running SIMPL Windows is available connect the PC to the Cresnet system via the computer port ...

Page 18: ...piled file for CNX generation with SIMPL header file usp projectname usp source code module for SIMPL SIMPL Symbol Intensive Master Programming Language Windows is Crestron s software for programming Crestron control systems It provides a well designed graphical environment with a number of workspaces i e windows in which a programmer can select configure program test and monitor a Crestron contro...

Page 19: ...rary and drop it in the System Views The PRO2 system tree displays the touchpanel in slot 9 with a default NET ID of 15 as shown in the following illustration NOTE The first C2N SPWS300 in a system is preset with a NET ID of 15 when its symbol is dragged into the upper pane of System Views Additional units are assigned different NET ID numbers as they are added C2Net Device Slot 9 Setting the Net ...

Page 20: ...NET ID already exists in the program Always ensure that the hardware and software settings of the NET ID match For NET ID hardware settings details refer to Identity Code on page 8 C2N SPWS300 Symbol in Programming Manager Programming Manager is where programmers program a Creston control system by assigning signals to symbols The following diagram shows the C2N SPWS300 symbol in the SIMPL Windows...

Page 21: ...the logical values true and false and they can be represented in an electronic device by the states on off or high low recognized as two voltage levels Other common descriptors are active inactive Analog Signals Unlike digital signals analog signals can vary continuously in value in the same manner as a parameter such as volume temperature or pressure Analog signals contain 16 bits of information ...

Page 22: ...hooting purposes Digital Input Signal Descriptions INPUT DESCRIPTION Chan1_Reset through Chan8_Reset High 1 Power to a given channel is cut off for as long as the signal is held high Power is restored on trailing edge Low 0 No external reset detected Main_Reset High 1 Shuts off system power drives all faults low Power is restored on trailing edge Low 0 No reset detected Status_Report_En High 1 All...

Page 23: ...ssed through the commands and options in the Viewport menus Therefore for its effectiveness as a support and diagnostic tool the Crestron Viewport may be preferred over development tools when uploading programs and projects The following sections define how one would upload a SIMPL Windows program or upgrade the firmware of the C2N SPWS300 However before attempting to upload or upgrade it is neces...

Page 24: ...rt 2 Refer to the following figure From the Viewport menu select Setup Communications settings alternatively depress Alt D to open the Port Settings window Setup Communications Settings Command 3 Select RS 232 as the connection type Verify that an available COM port COM 1 is shown after this step is selected and that all communication parameters and necessary options from the Port Settings window ...

Page 25: ...t be established refer to the Troubleshooting Communications section in the respective Operations Guide for the control system Uploading a SIMPL Windows Program A control system source file has the extension smw A compiled SIMPL Windows file has the extension spz for a 2 Series control system bin for CNX generation and csz for CNX generation with SIMPL The SIMPL Windows file can be uploaded to the...

Page 26: ...k boxes If the program does not contain any SIMPL modules only the SIMPL Program check box will be enabled If it does contain SIMPL modules then the SIMPL Program s check box will also be enabled Select one or both check boxes and then click Send Program to begin the transfer NOTE Refer to the respective Operations Guide for the control system for details about the other fields shown on the Send P...

Page 27: ...roves functions adds new features and extends the capabilities of its products firmware upgrades are posted To upgrade the firmware complete the following steps 1 Make sure that Communication Settings that begins on page 19 has been performed 2 As shown after this step select File Transfer Load Network Device from the Viewport menu File Transfer Load Network Device Command 3 As shown after this st...

Page 28: ...System Power Supply Crestron C2N SPWS300 24 System Power Supply C2N SPWS300 Operations Guide DOC 8190 Open Window 4 Browse to the desired upg file and click Open to begin the transfer ...

Page 29: ...eeds 300 watts Remove excessive load and press system RESET button Combination of high ambient temperature and excessive load Place unit in a well ventilated area reduce load press system RESET button and may possibly require cycling of power switch Some network units are not receiving power Varied From SIMPL Windows select Tools Network Analyzer and perform voltage level tests on the troubled net...

Page 30: ...Asia at 852 2341 2016 In Latin America call Crestron Latin America at 5255 5093 2160 In Australia and New Zealand call Crestron Pacific at 613 9480 2999 Future Updates As Crestron improves functions adds new features and extends the capabilities of the C2N SPWS300 additional information and programming examples may be made available as manual updates These updates are solely electronic and serve a...

Page 31: ...onents are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application oth...

Page 32: ...Crestron Electronics Inc Operations Guide DOC 8190 15 Volvo Drive Rockleigh NJ 07647 06 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...