Environmental Advice.
This product is covered by current WEEE regulations. Please consider the effect on the environment when
disposing of it. Do not put in a domestic waste bin. Only dispose of at an appointed recycling centre.
Specifications.
(Version dependant)
Case
Material:
ABS
Buttons:
Acetal
Operation:
1 or 2 button, latching or non-latching.
Reset Method:
Hold down both buttons for 5 seconds.
Operating
Voltage:
11-15v
DC
Quiescent Current at 12v:
30 mA
Anti-Tamper:
Normally closed tactile 24v DC at 1A max.
Relay contacts x 2:
1 single pole changover, 1 normally closed.
125VAC DC at 1A, 30 VDC at 2A
Delay:
0 - 2 minutes in 5 sec increments.
Dimensions:
85mm x 85mm x 39mm max
Fixing Screws:
Standard UK electrical 3.5mm
Standards: BS4737-3.14:1986
EN50131-1:2006+A2:2017
EN50130-5:2011
EPA-NG/STD/*/G3
EPA-NG/PLUS/*/G3
Operating and Installation
Instructions
Electronic
Panic Attack/Hold-up Device
UK Registered Design 4007887
RoHS compliant.
EPA-NG Issue 05
Both Versions include:
Two button operation, instant operation, latching, LED activation
indication, selectable EOL settings and keyless reset by holding down both buttons for 5 seconds.
Plus Version also includes:
Optional confirmed output, one or two button operation, timed
delay operation if required, latching or non latching, LED or no LED activation indicator.
4:-
Unconfirmed
/Confirmed operation (
this option is not available on standard version
).
Unconfirmed operation is the normal operating mode of any hold-up device, creating an alarm
situation on the button press.
If confirmed operation is selected, an alarm signal is generated on the first push of two buttons together
and the LED will turn orange. A confirmation signal is generated from a separate relay following a
second sustained push of 1.5 seconds of both buttons, the LED turns red. This second output signal may
be used to trigger another zone, or is capable of switching other equipment such as video or audio
devices. This secondary signal can be used as confirmation that the unit has not been accidentally
triggered. In the event that the confirmed operation is enabled and only the first double push is
received, the unit will only allow one minute to accept the second confirmed double push. After this
time the unit will reset automatically back to its normal state indicated by the green LED.
5:- Alarm
LED indication
/No indication (
t
his option is not available on standard version
).
Alarm indication is basically as already discussed. Normal healthy state is green, turning red on
activation. Flashing orange as required. If the no indication is enabled, the LED will only light green to
indicate power, and will stay lit throughout. This mode is not applicable in timed operation, which
requires the LED to indicate the state of operation. The LED will flash red to indicate incorrect selection.
6:-
Non EOL operation
/EOL operation
If EOL monitoring is required, enable via jumper and connect to NC1 and A/T2
The built in EOL resistance, which must be selected with jumpers are as follows:
Type A 1K
1K EOL selection
Type B 4K7
2K2 EOL selection
Type D 5K6
5K6 EOL selection
Type E 6K8
4K7 EOL selection
If EOL is required on the confirmed output, resistors must be fitted to the terminals NC2/NC3/Spare
as shown in diagram.
Reset
.
To reset after operation, push and hold down both buttons for 5 seconds. Green LED indication
confirms the reset.
Denotes finish
*
This product is suitable for use in systems installed to comform to PD6662:2017 at Grade 2 & 3
and environmental class II