Environmental Advice.

This product is covered by current WEEE regulations.  Please consider the effect on the environment when 
disposing of it. Do not put in a domestic waste bin.  Only dispose of at an appointed recycling centre. 

Specifications. 

(Version dependant)

 Case 

Material: 

 ABS

 Buttons: 

  Acetal

 

Operation: 

 

1 or 2 button, latching or non-latching.

 

Reset Method: 

 

Hold down both buttons for 5 seconds.

 Operating 

Voltage: 

 11-15v 

DC

 

Quiescent Current at 12v: 

30 mA

 

Anti-Tamper: 

 

Normally closed tactile 24v DC at 1A max.

 

Relay contacts x 2:   

1 single pole changover, 1 normally  closed.  

 

 

 

 

125VAC DC at 1A, 30 VDC at 2A 

 

 

 

 

Delay: 

 

 

0 - 2 minutes in 5 sec increments.

 

Dimensions: 

 

85mm x 85mm x 39mm max

 

Fixing Screws: 

 

Standard UK electrical 3.5mm

 Standards:  BS4737-3.14:1986
    EN50131-1:2006+A2:2017
    EN50130-5:2011

EPA-NG/STD/*/G3
EPA-NG/PLUS/*/G3

Operating and Installation

Instructions

 Electronic 

Panic Attack/Hold-up Device

UK Registered Design 4007887

RoHS compliant.

EPA-NG Issue 05

Both Versions include:

 

Two button operation, instant operation, latching, LED activation 

indication, selectable EOL settings and keyless reset by holding down both buttons for 5 seconds.

Plus Version also includes:

 

Optional confirmed output, one or two button operation, timed 

delay operation if required,  latching or non latching, LED or no LED activation indicator.

4:- 

Unconfirmed

/Confirmed operation (

this option is not available on standard version

).

 

Unconfirmed operation is the normal operating mode of any hold-up device,  creating an alarm 
situation on the button press. 
If confirmed operation is selected, an alarm signal is generated on the first push of two buttons together 
and the LED will turn orange. A confirmation signal is generated from a separate relay following a 
second sustained push of 1.5 seconds of both buttons, the LED turns red.  This second output signal may 
be used to trigger another zone, or is capable of switching other equipment such as video or audio 
devices. This secondary signal can be used as confirmation that the unit has not been accidentally 
triggered.  In the event that the confirmed operation is enabled and only the first double push is 
received, the unit will only allow one minute to accept the second confirmed double push.  After this 
time the unit will reset automatically back to its normal state indicated by the green LED.

5:- Alarm 

LED indication

/No indication (

t

his option is not available on standard version

).

Alarm indication is basically as already discussed. Normal healthy state is green, turning red on 
activation. Flashing orange as required. If the no indication is enabled, the LED will only light green to 
indicate power, and will stay lit throughout. This mode is not applicable in timed operation, which 
requires the LED to indicate the state of operation. The LED will flash red to indicate incorrect selection.

6:- 

Non EOL operation

/EOL operation 

If EOL monitoring is required, enable via jumper and connect to NC1 and A/T2
The built in EOL resistance, which must be selected with jumpers are as follows: 

 

Type A    1K    

1K   EOL selection

 

Type B    4K7  

2K2 EOL selection

 

Type D   5K6  

5K6 EOL selection

 

Type E    6K8  

4K7 EOL selection 

If EOL is required on the confirmed output, resistors must be fitted to the terminals NC2/NC3/Spare 
as shown in diagram.

Reset

To reset after operation, push and hold down both buttons for 5 seconds. Green LED indication 

confirms the reset.

Denotes finish

*

This product is suitable for use in systems installed to comform to PD6662:2017 at Grade 2 & 3 
and environmental class II