background image

71683 00 / Issue 1 / 13

CUSTOMER CARELINE 01746 713410

Equipment needed: 

Drill, 6.5mm Masonry Bit, 4.5mm & 3mm Metal Bits (general), Crosshead Screwdriver, 16mm Spanner, Spirit Level, Pencil, 
Tape Measure, Masking Tape, Silicone Sealant.

Note:

 The screws and wall plugs supplied are for masonry walls. For lightweight walls i.e. stud partition, plasterboard etc, 

use the correct type of fixings.

Please read these instructions carefully and keep for future reference. 

Incorrect fitting will invalidate the guarantee.

 SAFETY

● 

Handle glass with great care.  

  Although the glass is very tough, sharp impacts can damage both the glass and metal frame.

● 

Make sure there are no hidden pipes or cables hidden in the wall where you intend to drill.

● 

Wear safety goggles, shoes and appropriate clothing.

 BEFORE INSTALLATION

● 

Check that the shower tray is level in all directions. The enclosure will not sit correctly on an uneven surface.  

  If uneven, the wall channels may not fit and the doors may not shut correctly.

● 

The enclosure should be fitted on tiled walls which are sealed with waterproof grout.

 There must be a good silicone seal between the rim of the shower tray and the wall.

● 

The shower tray and the enclosure must match in size. Attempting to fit the incorrect size of enclosure to  

  the shower tray will result in water leaks.

● 

Always check very carefully that components are vertical.

● 

To avoid damage, use the opened out packaging to build the enclosure on.

PREMIER DOUBLE SLIDING DOOR  

/ SIDE PANEL

Sliding Door - 

Pages 2 - 8

Sliding Door & Side Panel - 

Pages 9 - 16

Summary of Contents for PREMIER

Page 1: ... cables hidden in the wall where you intend to drill Wear safety goggles shoes and appropriate clothing BEFORE INSTALLATION Check that the shower tray is level in all directions The enclosure will not sit correctly on an uneven surface If uneven the wall channels may not fit and the doors may not shut correctly The enclosure should be fitted on tiled walls which are sealed with waterproof grout Th...

Page 2: ...so that the bottom of the wall channel is sealed Failure to do this will cause water to leak under the wall channel and between the tray and tiles resulting in damp patches on the wall and under the tray 1 a b PN11031 PN11031 100mm max 100mm max ø 4 5 mm 1500 PN40272 1700 PN40273 Check contents of pack before installation If anything is missing contact our Customer Careline for assistance CUSTOMER...

Page 3: ...5mm holes 30mm deep and insert the wall plugs b Apply sealant to the back of the wall channels and around the fixing holes c Fix the wall channels to the walls using 8 x 32mm screws a b c a Place the bottom rail onto the tray with its end mouldings inserted into the wall channels b Centre the bottom rail between the wall channels so that there is an equal gap at each end 3 a b ø 6 5 mm Inside 32mm...

Page 4: ...e down so they fully slot onto the end mouldings of the bottom rail Inside the enclosure ensure the panels sit in the fixed panel brackets slide the brackets along the rail and position under the panels as shown 6 Position the top rail onto the top of the fixed panels Adjust the position of the fixed panel brackets as required Line up the holes and fix using 2 x 13mm screws 4 Fixed panel bracket O...

Page 5: ...8 Fit flipper seals PN40308 onto the edge of the fixed panels Ensure the flipper seal flaps are on the inside Note Wetting the glass with water will help to fit the seals From inside the enclosure place fixed panel retainer covers PN80618 onto the top and bottom fixed panel brackets Fix using the 12mm screws and fit the retainer caps PN50370 PN80618 Inside PN40308 PN50370 12mm Fixed panel bracket ...

Page 6: ... both plungers on the bottom door rollers and position under the bottom rail runner and release the plungers 10 From inside The wheels at the top of the doors may need adjusting so that the doors slide freely and the magnetic seals meet evenly when the doors are closed From outside the enclosure turn the adjuster screw under each of the top wheels as shown until the doors hang vertically 11 From i...

Page 7: ...31 a Insert 3 wall channel clips PN50359 down the slot in each wall channel and space out equally down their length b Push fit the wall channel cover strips PN11031 onto the wall channels as shown a b 14 a Check that the doors hit the top and bottom bumpers at the same time b To adjust the bumpers loosen the screw move the rubber bumper as required then re tighten Push fit cover caps PN4745 a b 13...

Page 8: ... of life This product contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre IMPORTANT You must not use the shower for 24 hours after installation of the enclosure DO NOT use bleach scouring powders solvents or other aggressive cleaning agents To clean use warm soapy water and a clean cloth and rinse off Please...

Page 9: ...ortant that the tray is sealed right up to the tray edge so that the bottom of the wall channel is sealed Failure to do this will cause water to leak under the wall channel and between the tray and tiles resulting in damp patches on the wall and under the tray 1 a b 1500 PN40272 1700 PN40273 SLIDING DOOR CONTENTS 8 PN3230 8 PN3225 32mm 2 PN4745 2 2 4 2 PN60093 12mm 6 4 6 PN60220 PN40309 PN40311 PN...

Page 10: ...s using 8 x 32mm screws a b c a Insert the side panel into the wall channel ensuring that the H2O label is on the outside of the enclosure Fit the corner post onto the side panel IMPORTANT The corner post MUST be fitted as shown above b Ensure that the corner post is vertical and the same distance in from the edges of the tray as the wall channels 4 a b X Y ø 6 5 mm Inside 32mm Note Assembly with ...

Page 11: ... is an equal gap at each end a b Check the side panel and corner post are vertical and that the side panel is centrally positioned between the corner post and wall channel From inside the enclosure in the positions shown drill through the corner post and wall channel into the side panel using a 3mm drill bit do not drill too deep Fix using 6 x 10mm screws 5 ø 3 mm Inside side panel 10mm 6 ...

Page 12: ...r seal flaps are on the inside of the fixed panels Note Wetting the glass with water will help to fit the seals 8 Position the fixed panels into the corner post and wall channel and slide down so they fully slot onto the end mouldings of the bottom rail Inside the enclosure ensure the panels sits in the fixed panel brackets slide the brackets along the rail and position under the panels as shown F...

Page 13: ...edge of the fixed panels Ensure the flipper seal flaps are on the inside Note Wetting the glass with water will help to fit the seals From inside the enclosure place fixed panel retainer covers PN80618 onto the top and bottom fixed panel brackets Fix using the 12mm screws and fit the retainer caps PN50370 PN80618 Inside PN40308 PN50370 12mm Fixed panel bracket 10 Check the door frame is vertical a...

Page 14: ... as shown until the doors hang vertically 14 From inside It is advised that this stage is carried out by two people to avoid damaging the runners rails or doors a From inside the enclosure hang the top door rollers onto the top rail runner b From outside with the door closed depress both plungers on the bottom door rollers and position under the bottom rail runner and release the plungers 13 From ...

Page 15: ...tighten Push fit cover caps PN4745 Inside a b 17 PN4745 a Assemble the towel rail brackets onto the ends of the towel rail and tighten using the supplied allen key b Attach the towel rail to the side panel ensuring the supplied towel rail washers are used on each side of the glass a b Outside of side panel 16 PN50359 a Insert 3 wall channel clips PN50359 down the slot in each wall channel and spac...

Page 16: ...osure DO NOT use bleach scouring powders solvents or other aggressive cleaning agents To clean use warm soapy water and a clean cloth and rinse off Please note There has been a glass coating applied to this product use a squeegee to remove water and debris Periodically check all fixings and tighten if necessary 20 From the outside only apply sealant to the bottom of the enclosure and 50mm up the w...