background image

Coral Box AquaLink A1

Quick Start Guide

Packing list

AQlink A1 main unit

X1

Quick Start Guide(this document)

X1

Features

Direct drive Jebao/Jecod DCT/DCS/DCP-series pumps, CP series
cross-flow pumps and compatible 3 phases pump/wave makers.

High performance fast response with sinusoidal current drive, offer
minimized rotor vibration and extra quiet operation.

Pump Selection : Up to 32 preset pump parameters.

Control Input : On-board RJ45 socket, using one analog channel can control
rotational speed, two analog channel can control clockwise and
counter-clockwise direction.

Continuous firmware upgrade to support new pumps, please contact your
sales for arrangement.

Specification

DC IN:12 – 24VDC adapter or Pump Extender, current up to 4A.

Control Voltage: 0 – 10VDC, 2 channels via RJ45 8P connection.

Pump Output: 24V 3 phases BLDC pump and wave maker.

Size and weight : Typical 10cm x 10cm x 2.7cm (W*L*H), 150g.

Suitable for:

DCA

2000

3000

6000

9000

DCS

2000

3000

4000

7000

9000

12000

DCP

3000

4000

5000

6500

8000

10000

DCT

3000

4000

6000

8000

12000

15000

CP

CP-25

CP-90

CP-40

CP-120

GF

150

DCW

4000

6000

9000

12000

DCQ

4000

6000

9000

12000

QP

QP-5

QP-9

QP-16

Reversed

Quick Start

1. Setting of Programming Switch: On the side of the
main unit there is a programming switch (Fig.1) with 5
slide levers, please refer to Fig.4, find your pump’s
model and set the slide levers accordingly. Please visit
www.coral-box.com for latest support list.

2. Connection to Variable Speed Control Unit : Use a
RJ45 cable to connect to the main unit’s RJ45 8P
socket. The pin definition of the RJ45 socket is as on
Fig.2. They are 0 - 10V DC input, applying voltage out
of this range will damage the unit permanently. CH1
1-10V corresponding to 10 -100%, and CH2 having no
connection or lesser than 2V DC, the pump will be in
default/clockwise direction, else if voltage of more
than 8VDC, the pump will rotates reversely.

3. Connection to Your Aquarium Pump: As on Fig.3, connect your pump to the
AQLink A1 “PUMP” cable.

Reviews: