background image

Operation and Maintenance Manual

BLIZZARD

50

CS6-50-VD

120V/60HZ

Summary of Contents for BLIZZARD50

Page 1: ...Operation and Maintenance Manual BLIZZARD50 CS6 50 VD 120V 60HZ ...

Page 2: ......

Page 3: ... pump and adjusting the water flow 4 5 0 Maintenance and storage 4 5 1 Removing the cooling media accessing the inside of the unit 4 5 2 Daily maintenance 5 5 3 Periodic maintenance 5 5 4 Storage 5 6 0 Troubleshooting Repair 6 6 1 Troubleshooting 6 6 2 Repair procedures 9 6 3 Technical support 9 7 0 Warranty 10 7 1 Warranty form 10 7 2 Warranty parts 10 7 3 Optional accessories and replacement par...

Page 4: ... examine the carton for damage before opening If the carton is damaged notify the shipping company immediately 3 0 Set up of the COOL SPACE unit The COOL SPACE unit is factory tested and ready to use The unit should be placed on a level surface and the casters locked to prevent inadvertent movement Follow instructions below to connect water and electrical supply 3 1 Connecting the water supply Do ...

Page 5: ...nductor heavy duty cord required Do not exceed the amperage ratings of the extension cord Undersized extension cords result in excessive drops in voltage which cause the electric motors to generate excessive heat This condition results in inefficient motor operation and premature motor failure WHICH WILL VOID THE WARRANTY Table 1 Electrical Requirements CS Model Number Volts 10 Frequency Hz Runnin...

Page 6: ...nit from the cooling area This ensures that the COOL SPACE unit does not recirculate air that has already been through the evaporative cooling process The COOL SPACE unit must be placed on a level surface to operate correctly Units create an oval shaped air pattern Obstacles such as racks and workbenches may interfere with the air flow An attempt should be made to locate the unit in such a manner ...

Page 7: ...of the unit it controls the volume of water that is delivered to the top of the cooling pads Prolonged use of hard water without proper water treatment will create mineral deposit build up causing the pump to fail which is NOT COVERED BY WARRANTY Pump is equipped with a LOW WATER CUT OFF which may take up to 5 minutes to reset each time 5 0 Maintenance and storage ELECTRICAL SHOCK HAZARD Disconnec...

Page 8: ...vailable at www cool space com Draining the Water Sump 1 Close the water flow valve and open the drain valve 2 Run pump until it shuts off automatically The sump will not be completely empty 3 Turn unit off and disconnect the power supply 4 Remove cooling pads refer to section 5 1 5 Clean out reservoir with either a towel or wet dry vacuum 6 Remove the water spray bar and its plug Insure holes are...

Page 9: ... system has a problem you must define the associated problem e g the pump is not running Although this might seem a bit simplified several things may cause this particular problem So while defining the problem a careful check of all systems should be made to fully understand the extent of the problem If you have a complete understanding of all of the systems of the COOL SPACE unit and how they dep...

Page 10: ...oat valve is loose at bulkhead fitting Water pressure is too high to allow float valve to shutoff 120psi max Tighten connections and or replace hose washers Reduce water pressure by adding an inline reducer Water spitting from the unit or dripping from pads Flow of water too strong Cracked Hose Valve Assembly Hose connection loose Drip retainer on spray bar Ensure pads were installed correctly Red...

Page 11: ...e running Object s in impellor impellor loose Pump bearings bad Remove object s Replace pump Breaker trips or fuse blows when switch is turned on Check power cord length and breaker rating Check for locked up pump Refer to page 2 for unit amperage draw and to determine required cord gauge Replace pump Pump won t run and power is available Pump is functional Make certain switch is working Is water ...

Page 12: ... reinstallation 6 Install arms and blade on new motor 7 Install fan in opening and secure with mounting bolts 8 Reconnect wires and tie cord to motor arm to keep them out of fan Pump Replacement 1 Disconnect hose from pump 2 Unplug the cord from the top of the pump by removing 2 screws 3 Remove pump from water sump and install new pump 4 Reverse the above procedures to reconnect the wiring lift pu...

Page 13: ...ed your COOL SPACE unit If you have any questions or concerns please contact us direct at 1 800 557 5716 or at sales cool space com Please have your model number and serial number ready DO NOT DISCARD FAULTY PARTS Check with the Manufacturer as they may need to be returned for warranty credit 7 3 Optional Accessories and Replacement Parts Accessories and replacement parts are available from your l...

Page 14: ......

Page 15: ...CS MAN 50V60H 02162018al 315 N Madison Street Fortville IN 46040 317 577 0417 800 557 5716 support cool space com www COOL SPACE com ...

Page 16: ...run for 10 minutes and then shut down Puts machine into shutdown mode When pressed the pump shuts off and the fan will continue to run for 15 minutes and then shut down Works in auto and manual mode Fan Pump Auto Manual Mode 15 Min Countdown Timer Remote Sensor Power Indicator Red Light Power Connected Green Light Power On Low Water Indicator Power On Off Fan REM ...

Reviews: