EXT

 LINK 2.4 is the only blood glucose monitoring 

system (BGMS) approved as part of the 

MiniMed

®

 630G

 

and 

MiniMed

®

 670G

 systems. The meter is designed to be 

used exclusively for Continuous Glucose Monitoring (CGM) 

calibration and insulin administration decisions as part of the 

MiniMed 630G

 and 

MiniMed 670G

 systems.

The C

ONTOUR

 N

EXT

 LINK 2.4 BGMS is highly accurate and 

has been demonstrated to close the gap between laboratory 

accuracy and real world test results.

11

 Clinical studies show 

that differences in BGMS accuracy could result in clinically 

important differences in insulin dosing.

12, 13

USER GUIDE

120

mg

dL

 Before Meal

12:24 PM l 10/13

Bolus

Reminder

Notes

Uses only C

ONTOUR

®

N

EXT

 

Blood Glucose Test Strips

120

 

mg/dL

BG

12:24

PM

Active Insulin  0.0 u

MiniMed

®

 670G is shown

Wireless Blood Glucose 
Monitoring System

DATE:

CLIENT:

DESCRIPTION:

SCHAWK JOB#:

SKU#:

DIMENSIONS:

PRINTER SPEC:

RELEASE: V-5

LANGUAGE(S):

ENGLISH

INTERNAL: R-X

18211 NE 68th Street, E120 

Redmond, WA 98052 

T: 425-881-5454

BAN#: 85587269  

Rev. 11/16

Contour Next LINK 2.4 UG - US

Alt#1 - 11/07/16 Copy changes

Alt#2 - 11/10/16 Line art insertion

Alt#3 - 11/15/16 Copy changes

Alt#4 - 11/18/16 Copy changes

Alt#5 - 11/21/16 Copy changes

November 21, 2016

Ascensia Diabetes Care

Contour Next LINK 2.4 UG US - 

English

920970

Multi  Parent BAN#: 81914672

7.5" (H) x 6.5" (W)

10000752630 REV -

FONTS:

Helvetica, Helvetica Neue, Zapf Dingbats, Skinny Mini, Mini Micra, Myriad Pro, Arial

COLORS:

 Cyan

 

 

Magenta 

 

Yellow 

 

Black  

281 Process Build: 100C 79M 10Y 42K

NOTE: THIS COLOR PROOF INDICATES COLOR BREAK ONLY AND MAY NOT ACCURATELY REFLECT ACTUAL PRODUCTION COLOR.

Clinical Trials Template No: XXXXX

Global Master Template No: XXXXX

85587269_CntrNextLINK_2_4_UG_EN_FpBp_v5.indd   ofc1

11/21/16   2:40 PM

Summary of Contents for LINK 2.4

Page 1: ...BGMS is highly accurate and has been demonstrated to close the gap between laboratory accuracy and real world test results 11 Clinical studies show that differences in BGMS accuracy could result in clinically important differences in insulin dosing 12 13 USER GUIDE 120 mg dL Before Meal 12 24 PM l 10 13 Bolus Reminder Notes Uses only CONTOUR NEXT Blood Glucose Test Strips 120mg dL BG 12 24 PM Acti...

Page 2: ...et a similar result call your health care professional as soon as possible About whether Alternative Site Testing AST is appropriate for you Potential Biohazard Always wash and dry your hands well with soap and water and dry them well before and after testing handling the meter lancing device or test strips The meter lancing device and lancets are for single person use Do not share them with anyon...

Page 3: ...ing and turns off NOTE Your meter can Rapid Charge After 1 minute of charging you can unplug the meter and run one blood sugar test if needed A USB extension cable is included for your convenience OR Remove USB cap Insert the meter USB plug into your computer or use the USB extension cable Be sure your computer is turned on and not in sleep hibernate or power save mode Wall charger may not be incl...

Page 4: ...Bp_v4 indd 3 11 18 16 9 03 AM 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 2 11 18 16 9 03 AM 3 GETTING STARTED Before Meal mg dL 12 24 PM l 10 13 93 Bolus Reminder Notes Selection Scrolling Buttons See page 5 Display Screen Meter USB Plug Top Menu Button See page 4 Protective USB Cap Test Strip Port Insert the test strip here To turn on the test strip port light see page 4 Your CONTOUR NEXT Test ...

Page 5: ...nnected to your MiniMed insulin pump Your CONTOUR NEXT LINK 2 4 meter and MiniMed insulin pump must be within 6 feet of each other MiniMed 630G MiniMed 670G BG Active Insulin Bolus Basal 1 5 u mg dL 12 24 PM BG Active Insulin 0 0 u mg dL 12 07 AM Graph Display Screen Menu Select Right Right Up Back Back Left Down Notification Light 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 4 11 18 16 9 03 AM 5 ...

Page 6: ...o step 7b 7b Press Select button Use the Down arrow button to scroll to Options Press Select button Set Language Menu Insulin Settings Sensor Settings Event Markers Reminders Utilities Enter BG Basal Audio Options Status Suspend Delivery Options OR For the MiniMed 670G For the MiniMed 630G 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v5 indd 6 11 21 16 2 37 PM 7 GETTING STARTED Connect Device Manual Conne...

Page 7: ... meter Search Cancel Use Pump to confirm Device SN BGJ133333F 14 Check that the Device SN serial number on the pump screen matches the meter SN on the meter screen If they match Confirm on the pump Press Select button CONNECT TO PUMP Confirm Searching Start search on new device Search may take up to 2 minutes 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 8 11 18 16 9 03 AM 9 GETTING STARTED PUMP CO...

Page 8: ...de The date format you choose on the meter applies to the meter only Month Day Year Day Month Year DATE FORMAT SELECT 20 The Date Format screen appears on your meter Choose your date format AutoLog The AutoLog feature lets you mark your test result as Fasting Before Meal After Meal No Mark Your meter comes preset with AutoLog turned OFF 22 When the AutoLog screen appears press Accept to keep AutoL...

Page 9: ...gets can only be set inside your selected Alert level s For additional information you may contact Customer Service Contact information for Customer Service is on the back cover WARNING Talk to your health care professional before setting any Target ranges on your meter Target Ranges 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 12 11 18 16 9 03 AM 13 TESTING Testing Getting Ready to Test Read your...

Page 10: ...ncet 5 Replace the endcap 3 Insert the lancet firmly into the lancing device until the lancet comes to a full stop 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 14 11 18 16 9 03 AM 15 TESTING APPLY BLOOD 2 Hold the test strip with the gray square end facing up 3 Insert the gray square end into the test strip port until the meter beeps if the Sound is set to ON Getting the Blood Drop Fingertip Testi...

Page 11: ...g Off If the first blood drop is not enough the meter will beep twice and display STRIP UNDERFILLED and APPLY MORE BLOOD NOW You have about 30 seconds to apply more blood to the same strip CAUTION Always check the display on your pump to ensure that the glucose result shown agrees with the glucose result shown on the meter 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 16 11 18 16 9 03 AM 17 TESTING...

Page 12: ...els may not rise as high or fall as low as levels in the fingertip As such fingertip testing results may identify hypoglycemic levels sooner than alternate site results Alternative Site Testing is recommended only when it is more than 2 hours after a meal diabetes medication or exercise If you do not have a clear endcap to perform AST contact Customer Service Please see back cover for contact info...

Page 13: ...or Don t Send If Send is chosen press OK on the Send confirmation screen You can change your send option at any time using the Setup Menu see page 42 WARNING Do not calculate a bolus based on an AST result Do not calibrate your continuous glucose monitoring device from an AST Ejecting and Disposing of the Used Lancet 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 20 11 18 16 9 03 AM 21 TESTING WARNI...

Page 14: ...ng in the Dark Your meter has a lighted test strip port to help you test in the dark With the meter off give the top Menu button two quick presses to turn on the test strip port light Insert a test strip and the display screen appears Once blood is applied to the test strip the light goes off Continue with your test Two quick presses of the top Menu button also turns off the light 85587269_CntrNex...

Page 15: ...about 15 times before every use Do not apply control solution to your fingertip or to the test strip directly from the bottle 6 Remove the bottle cap and use a tissue to wipe away any solution around the bottle tip before dispensing a drop 7 Squeeze a small drop of control solution onto a clean nonabsorbent surface 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 24 11 18 16 9 03 AM 25 FEATURES OK Fas...

Page 16: ... test result is still displayed on the meter press Bolus If Block Mode is ON at the pump you are asked if you want to proceed with the bolus Block Mode is a MiniMed pump setting that restricts access to critical pump settings Please see your MiniMed insulin pump user guide for more detailed instructions 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 26 11 18 16 9 03 AM 27 FEATURES Bolus Total Stop B...

Page 17: ...o begin the countdown The preset time is 2 hours or if you have changed it the last reminder time that you set is now the default OR from the Setup Menu press the button to highlight Reminder Off Press OK to turn the Reminder ON You can change the Reminder Countdown time by pressing Change Setting a Test Reminder 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 28 11 18 16 9 03 AM 29 FEATURES REMINDER...

Page 18: ...ne or more notes by repeating the steps above The notes will scroll across the bottom so that you can read them all While you can add more than one note only one AutoLog option can be chosen e g Fasting Before Meal or After Meal Notes 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 30 11 18 16 9 03 AM 31 USING THE MAIN MENU LOGBOOK 167 mg dL Sent Before Meal 11 06 09 10 30 AM END OF LOGBOOK 97 mg dL ...

Page 19: ... included in the average and the number of tests above within and below Target Trends Averages and Summaries Viewing Trends With AutoLog On 1 Press and hold the top Menu button to turn the meter on 2 Press the button to highlight Trends Press OK to select This example shows that your Before Meal average is 128 mg dL and 38 test results are included in the Before Meal average with 26 within the Tar...

Page 20: ...iMed Pump connected Connect now PUMP OPTIONS Yes No Menu Insulin Settings Event Markers Reminders Utilities Sensor Settings Connecting to the Pump Using Auto Connect Utilities Self Test Carb Unit Manage Settings Sensor Demo Device Options Device Options Manage Devices OR For the MiniMed 670G For the MiniMed 630G Connect Device 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 34 11 18 16 9 03 AM 35 USI...

Page 21: ...number This number is the pump SN PUMP CONNECTED MiniMed Pump connected AA1234567B Next Delete 15 Then press Next on your meter NOTE To remove this pump press Delete The Connect to Pump process starts over to allow you to connect to a different pump 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 36 11 18 16 9 03 AM 37 USING THE MAIN MENU 17 After the meter and pump are connected you set your Send Op...

Page 22: ...he button to highlight Setup Press OK to select 6b Press Select button Use the Down arrow button to scroll to Options Press Select button Enter BG Basal Audio Options Status Suspend Delivery Options Connecting to the Pump Using Manual Connect Menu Insulin Settings Sensor Settings Event Markers Reminders Utilities OR For the MiniMed 670G For the MiniMed 630G 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 ...

Page 23: ...zes the time and date with the pump 14 Press Next on the meter 11 Place the meter and pump next to each other Select Search on your pump Select Search on your meter Search Cancel CONNECT TO PUMP Select Search on Your Pump and meter The search may take up to 2 minutes 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 40 11 18 16 9 03 AM 41 USING THE MAIN MENU Automatically send results to the Pump Alway...

Page 24: ...onic devices on an aircraft 1 Press and hold the top Menu button to turn the meter on 2 Press the button to highlight Setup Press OK to select Changing the Send Option 5 To change the current Send Option press Change 6 Choose the Send Option that is best for you 7 A confirmation screen appears Press OK to return to Pump Options 3 Press the button to highlight Pump Options Press OK to select 855872...

Page 25: ...ted minutes press OK Turning Off a Reminder Turning Off a Reminder To turn off a reminder you can use the Setup Menu or do a blood sugar test within 15 minutes of the reminder time To use the Setup Menu 1 Press and hold the top Menu button to turn the meter on 2 Press the button to highlight Setup Press OK to select 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 44 11 18 16 9 03 AM 45 USING THE MAIN...

Page 26: ... and Time When Connected to a Pump When connected to a pump you can change the date and time at the pump The date and time are synchronized to the pump when the meter is first connected to the pump when a blood sugar result is sent to the pump or if you select the Date or Time option in the Setup Menu 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 46 11 18 16 9 03 AM 47 USING THE MAIN MENU SETUP OK ...

Page 27: ...og setting to ON you are asked to confirm your Target settings for Fasting Before Meal and After Meal Your test result does not display until you make an AutoLog selection If your result is above or below your High or Low Alert settings you will see your result without pushing a button 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 48 11 18 16 9 03 AM 49 USING THE MAIN MENU AutoLog Target Trends Ran...

Page 28: ...oLog is ON your CONTOUR NEXT LINK 2 4 meter comes preset with the following Target ranges for testing Fasting 70 130 mg dL Before Meal 70 130 mg dL After Meal 70 180 mg dL Ranges can be changed to personal Targets decided by you and or your health care professional 1 Press and hold the top Menu button to turn the meter on 2 Press the button to highlight Setup Press OK to select 85587269_CntrNextLI...

Page 29: ...f you are speaking to a Customer Service representative They will give you a code that enables them to verify certain settings It is not for use any other time Please see back cover for contact information 4 Press the or button to select the language you prefer Press to see more choices Press OK 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 52 11 18 16 9 03 AM 53 TECHNICAL CARE For more information...

Page 30: ...flashes during charging and stops flashing and turns off when charging is complete Please remove the meter and store in the Carrying Case until you are ready to test If you do not charge the battery a display alerts you Shutting down Battery is dead You must charge immediately This screen displays full battery 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 54 11 18 16 9 03 AM 55 TECHNICAL CARE Do No...

Page 31: ... Shakiness Sweating Fast Heartbeat Blurred Vision Confusion Passing Out Irritability Seizure Extreme Hunger Dizziness Frequent Urination Excessive Thirst Blurred Vision Increased Fatigue Hunger Shortness of Breath Nausea or Vomiting Very Dry Mouth 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 56 11 18 16 9 03 AM 57 TECHNICAL CARE Table 2 System accuracy results for glucose concentration 75 mg dL Wi...

Page 32: ...nical action likely to affect clinical outcome D Altered clinical action with possibly significant medical risk E Altered clinical action with possibly dangerous consequences 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 58 11 18 16 9 03 AM 59 TECHNICAL CARE Table 6 System repeatability results for CONTOUR NEXT LINK 2 4 meter using CONTOUR NEXT test strips Mean mg dL Pooled Standard Deviation Coeff...

Page 33: ... glucose dehydrogenase FAD GDH and the mediator Electrons are generated producing a current that is proportional to the glucose in the sample After the reaction time the glucose concentration in the sample is displayed No calculation is required Comparison Options The CONTOUR NEXT LINK 2 4 system is designed for use with capillary whole blood Comparison to a laboratory method must be done simultan...

Page 34: ...c devices in very dry environments especially if synthetic materials are present The CONTOUR NEXT LINK 2 4 meter meets the requirements of IEC 61326 1 for radio frequency interference To avoid radio frequency interference do not use the CONTOUR NEXT LINK 2 4 meter near cellular or cordless telephones walkie talkies garage door openers radio transmitters or other electrical or electronic equipment ...

Page 35: ...ribed above in Cleaning Your Meter Cleaning Your Lancing Device Supplies Needed for Cleaning Clorox Germicidal Wipes containing 0 55 sodium hypochlorite bleach Paper towels 1 Clean the lancing device with Clorox Germicidal Wipes until all soil is removed 2 Dry as necessary with a clean paper towel 2 Dry all meter surfaces and test strip port using a clean paper towel if needed Strip Port USB Conne...

Page 36: ... pump Endocr Pract 2014 20 10 1016 1021 13 Pardo S Pflug B Dunne N Simmons DA Comparison of bolus insulin dose error distributions based on results from 2 clinical trials of blood glucose monitoring systems Presented at 14th Annual Meeting of the Diabetes Technology Society November 6 8 2014 Bethesda MD CONTOUR NEXT LINK 2 4 user guide CONTOUR NEXT LINK 2 4 quick reference guide USB extension cabl...

Page 37: ...n 17 Testing Your Blood Sugar 13 Time 45 Format 12 hour or 24 hour clock 46 Setting Connected to Pump 46 Setting Not Connected to Pump 45 Trends Averages Summaries 32 Viewing with AutoLog Off 32 Viewing with AutoLog On 32 Trends Range Setting 51 Turning Meter Off On 4 Underfilled Strip 16 USB Extension Cable iv Warranty 67 Website Back cover Wireless Turning On Off 42 85587269_CntrNextLINK_2_4_UG_...

Page 38: ..._v4 indd 70 11 18 16 9 03 AM 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 71 11 18 16 9 03 AM 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v4 indd 71 11 18 16 9 03 AM 11 18 16 9 03 AM 85587269_CntrNextLINK_2_4_UG_EN_FpBp_v5_UnMaskedPlaced pdf 74 ...

Page 39: ...ascensia com Ascensia the Ascensia Diabetes Care logo Clinilog Contour Glucofacts and the No Coding logo are trademarks and or registered trademarks of Ascensia Diabetes Care Holdings AG All other trademarks are the property of their respective owners Bolus Wizard CareLink Guardian MiniMed and Paradigm are trademarks and or registered trademarks of Medtronic MiniMed Inc 2016 Ascensia Diabetes Care...

Reviews: