background image

 
 

 

 
 
 
 

 
 

 

Titan/cPCI 

 

 
 
CompactPCI Serial Communications 
 
User Manual 

 
 
 
 
 
Connect Tech Inc 
42 Arrow Road 
Guelph, Ontario 
N1K 1S6 

Tel:  

  519-836-1291 

Toll: 

 800-426-8979 (North America only) 

Fax:  

  519-836-4878 

 

 

     Email: 

[email protected] 

 

 

           

[email protected] 

 

 

     URL: 

www.connecttech.com 

 
 

 
 
 
 
 
 
 
 
 
 
 
CTIM-00009, Revision 1.01 February 2006

 

Summary of Contents for Titan/cPCI

Page 1: ...r Manual Connect Tech Inc 42 Arrow Road Guelph Ontario N1K 1S6 Tel 519 836 1291 Toll 800 426 8979 North America only Fax 519 836 4878 Email sales connecttech com support connecttech com URL www connecttech com CTIM 00009 Revision 1 01 February 2006 ...

Page 2: ... Tech Inc reserves the right to substitute an equivalent product if available or to retract Life Time Warranty if no replacement is available The above warranty is the only warranty authorized by Connect Tech Inc Under no circumstances will Connect Tech Inc be liable in any way for any damages including any lost profits lost savings or other incidental or consequential damages arising out of the u...

Page 3: ...B 003 du Canada Connect Tech Inc declares that the product s covered by the contents of this manual have been tested and found compliant with the below listed standards as required by the Electromagnetic Compatibility EMC Directive for General Immunity Compliance EN 50 0082 1 1997 EN 55022 Conducted and Radiated emissions Class A EN 61000 4 2 Electrostatic Discharge EN 61000 4 3 Radiated Immunity ...

Page 4: ...ne Interface 10 Line Termination 11 Software Installation 11 Introduction 11 Appendix A Specifications 12 Operating Environment 12 Power Requirements 12 CompactPCI Bus Interface 12 Communications 12 Control Signals 12 Surge Suppression 13 Optical Isolation 13 Dimensions 13 Connectors Interface 13 Appendix B Connectors Pinouts 14 Connector Pinouts 14 Appendix C Factory Settings 17 Titan cPCI Adapte...

Page 5: ...our port adapters 4 Figure 2 Titan cPCI Model TN004 for compatibility with 64 bit systems 5 Figure 3 Titan cPCI TN003 Adapter with LEDs 5 Figure 4 Titan cPCI Rear I O two and four port adapters 6 Figure 5 Titan cPCI Rear I O Opto two and four port adapters 7 Figure 6 10 port configuration using Front and Rear I O 8 Figure 7 RS 422 485 Partial Schematic 21 Figure 8 RS 422 485 partial schematic for ...

Page 6: ...nterfaces Full RS 422 485 support in the following modes Full Duplex Mode Half Duplex Mode Multi drop Slave Mode 16C950 UARTs Independent baud rate selection per port offering baud rates from 50 bps to 1 8342 Mbps RS 422 485 or 230 4 Kbps RS 232 with 5 6 7 or 8 data bits and 1 1 5 2 stop bits odd even mark and space parity TransGuard Transient Voltage Suppression surge suppression IEC 1000 4 compa...

Page 7: ...ourier You may contact us by letter at Connect Tech Inc Technical Support 42 Arrow Road Guelph Ontario Canada N1K 1S6 Email Internet You may contact us through the Internet Our email and URL addresses on the Internet are sales connecttech com support connecttech com www connecttech com Note Please go to the Download Zone or the Knowledge Database in the Support Center on the Connect Tech website f...

Page 8: ...ar I O adapter if applicable Cable harness optional with four port models only Titan cPCI device drivers One CD containing software and documentation If any of these components is missing contact Connect Tech See Contact Details or your reseller Please read before you install your Titan cPCI Some Titan cPCI cards are designed with rear I O capabilities These are 32 bit cards The Titan cPCI cards w...

Page 9: ...dle Line Termination Bias Jumper blocks JC JD Duplex Control Jumper Block JA RS 232 Select Jumper Block JB DB 9 Connector Port 1 Titan cPCI Adapter 4 port model Rear I O Connector CompactPCI Bus Connector PCI 954 Quad UART DB 37 Connector Ejector Handle Jumper blocks JC JD JE JF Duplex Control Jumper Block JA RS 232 Select Jumper Block JB Figure 1 Titan cPCI two and four port adapters ...

Page 10: ...onnector PCI 954 Quad UART Tx Rx LEDs Ejector Handle Jumper blocks JC JD JE JF Duplex Control Jumper Block JA RS 232 Select Jumper Block JB Figure 3 Titan cPCI TN003 Adapter with LEDs Titan cPCI Adapter Model TN004 Compatible with 64 bit systems CompactPCI Bus Connector PCI 954 Quad UART DB 37 Connector Ejector Handle Jumper blocks JC JD JE JF Duplex Control Jumper Block JA RS 232 Select Jumper Bl...

Page 11: ...3 Ejector Handle DB 37 Connector Ejector Handle Rear I O Connector Rear I O Connector DB 9 Connector Port 2 DB 9 Connector Port 1 Titan cPCI Rear I O 4 port model Jumper J1 5 12V Select Jumper J2 DSR Power Select Ports 1 2 Jumper J3 DSR Power Select Ports 3 4 Jumper J4 Direct GND J4 Jumper J1 5 12V Select Jumper J2 DSR Power Select Ports 1 2 Jumper J4 Direct GND ...

Page 12: ...Rear I O Opto 2 port model Titan cPCI Rear I O Opto 4 port model RJ 45 Connector Port 2 RJ 45 Connector Port 1 RJ 45 Connector Port 2 RJ 45 Connector Port 1 RJ 45 Connector Port 3 RJ 45 Connector Port 4 Jumpers JA JB JC JD RS 232 RS 422 485 Select RS 422 485 Mode Control TxD RxD CTS RTS termination bias Jumpers JA JB RS 232 RS 422 485 Select RS 422 485 Mode Control TxD RxD CTS RTS termination bias...

Page 13: ...t Computer Printer Modem Terminals Titan cPCI 4 port model Titan cPCI 2 port model Printer Modem Printer Modem Terminals Titan cPCI Rear I 0 Opto 2 port model Titan cPCI 4 port model Figure 6 10 port configuration using Front and Rear I O Note When you have a Titan cPCI Rear I O adapter installed the corresponding number of Titan cPCI ports in the front I O section are not available Titan cPCI Sof...

Page 14: ...adapter into an available rear 3U slot The black handle on the front panel should be on the bottom in the lowered position 4 Push the Titan into the cPCI slot until the handle mates with the card cage Lift the handle to lock the Titan into place 5 With a screwdriver fasten the screw on the top of the panel into the card cage for added mechanical security Your Titan cPCI and Rear I O adapters are v...

Page 15: ...u must remove ALL jumpers on the front I O Titan cPCI when you are using the Rear I O Opto Baud Rate Selection Titan cPCI adapters offer ideal solutions for applications requiring serial communications up to 1 8432 Mbps Baud rates are software selectable please refer to Software Installation for configuring the baud rates under certain operating systems RS 422 485 Line Interface The Titan cPCI ada...

Page 16: ...cess to multiple 8250 style UARTs Titan cPCI adapters currently ship with device drivers for the following operating systems QNX 4 QNX 6 Windows NT Linux Before installing the Titan cPCI software device driver verify and note jumper settings described in Appendix D RS 485 422 Line Interface for Jumper block JA Full duplex half duplex and multi drop slave control Jumper block JB RS 232 RS 485 422 s...

Page 17: ...al Titan cPCI Rear I O Opto 2 port model 5 VDC 5 425 mA typical Titan cPCI Rear I O Opto 4 port model 5 VDC 5 900 mA typical CompactPCI Bus Interface Titan cPCI One 3U cPCI slot Titan cPCI Rear I O One 3U cPCI rear I O slot Communications UARTs 16C950 UARTs with 128 byte TxD RxD FIFO buffers RS 232 Programmable baud rate generator up to 230 4 Kbps on all ports RS 422 485 Programmable baud rate gen...

Page 18: ... signal of every port EN61000 4 2 3 4 compatible Optical Isolation Titan cPCI Rear I O Opto 2 4 port models 3 0kV AC peak to peak on every signal of every port Dimensions 3U cPCI compliant Connectors Interface Titan cPCI Titan cPCI Rear I O 2 port model Male DB 9 Titan cPCI Titan cPCI Rear I O 4 port model Optional cable harness with DB 37 to four male DB 9 connectors Titan cPCI Rear I O Opto 2 4 ...

Page 19: ...ignal Direction RS 422 485 Signal Direction 1 DCD input RxD input 2 RxD input RxD input 3 TxD output TxD output 4 DTR output TxD output 5 SG signal ground SR signal reference 6 DSR or 5V or 12V input CTS input 7 RTS output RTS output 8 CTS input CTS input 9 RI input RTS output This option is jumper selectable on the Titan cPCI Rear I O adapter only Male DB 9 Connector 1 5 6 9 Cable Part Number CAB...

Page 20: ...15 2 SG signal gnd SR signal ref 16 2 DTR output TxD output 17 2 TxD output TxD output 18 2 RxD input RxD input 19 2 DCD input RxD input 20 1 RI input RTS output 21 1 CTS input CTS input 22 1 RTS output RTS output 23 1 DSR or 5V or 12V input CTS input 24 3 SG signal gnd SR signal ref 25 3 DTR output TxD output 26 3 TxD output TxD output 27 3 RxD input RxD input 28 3 DCD input RxD input 29 4 SG sig...

Page 21: ...irection RS 422 485 Signal Direction 1 9 N C no connect RTS output 2 1 N C input RxD input 3 7 RTS output RTS output 4 5 SG signal ground SR signal ref 5 3 TxD output TxD output 6 2 RxD input RxD input 7 5 Gnd ground SR signal ref 8 8 CTS input CTS input 9 4 DTR output TxD output 10 6 N C no connect CTS input This cable is optional RJ 45 connector 1 10 ...

Page 22: ...JF are set for all ports not terminated or biased all positions not jumpered Please see Figure 1 for the locations of these jumper blocks Titan cPCI Rear I O adapters Function Factory Setting Electrical Interface Jumper blocks JA JB JC JD are set for all ports RS 422 485 positions 1 not jumpered Half Duplex 2 wire Jumper blocks JA JB JC JD are set for all ports running in full duplex or multi drop...

Page 23: ...2 wire Jumper blocks JA JB JC JD are set for all ports running in full duplex or multi drop slave mode positions 2 not jumpered Termination Jumper blocks JA JB JC and JD are set for all ports not terminated or biased positions 3 4 5 6 7 and 8 not jumpered Please see Figure 5 for the locations of these jumper blocks Note to Rear I O Opto users All jumpers must be removed from the Front I O Titan cP...

Page 24: ... tips or release notes concerning installation and configuration of various device drivers and software utilities If you require further information please contact Connect Tech Technical Support Example 1 This example shows the settings on jumper block JB so that port 2 is set for RS 232 and ports 1 3 4 are set for RS 422 485 JB Jumper Legend Jumpers on RS 232 enabled Port 1 Port 2 Port 3 Port 4 4...

Page 25: ...ting to cause the transmit driver to disable tri stated and the receiver to enable The 16C950 UARTs on the Titan cPCI adapter are responsible for timing the DTR toggle Multi drop Slave Mode 4 wire By not installing jumpers on jumper block JA and by using features in our driver software you can run the individual RS 422 485 ports in multi drop slave mode In this mode the TxD line driver is enabled ...

Page 26: ...l schematic of the RS 422 485 circuit for the Titan cPCI and to Figure 1 for the locations of JC JD JE and JF TxD TxD RxD TxD RxD Titan cPCI RS 422 485 Line Bias Termination RxD RTS RTS CTS RTS CTS CTS PCI 954 UART 150 Ω 1 8K Ω 1 8K Ω 5 V 150 Ω 1 8K Ω 1 8K Ω 5 V 150 Ω JC5 JD5 JE5 JF5 150 Ω JC6 JD6 JE6 JF6 JC3 JD3 JE3 JF3 JC4 JD4 JE4 JF4 JC1 JD1 JE1 JF1 JC2 JD2 JE2 JF2 10K Ω DTR JA0 JA1 JA2 JA3 Fig...

Page 27: ...rminated JC PORT 1 Jumper Legend 1 CTS terminator and bias 2 CTS terminator and bias 3 RxD terminator and bias 4 RxD terminator and bias 5 TxD terminator 6 RTS terminator JC1 JC2 JC3 JC4 JC5 JC6 JD PORT 2 JD1 JD2 JD3 JD4 JD5 JD6 JE PORT 3 JE1 JE2 JE3 JE4 JE5 JE6 JF PORT 4 JF1 JF2 JF3 JF4 JF5 JF6 Technical Notes 1 For full duplex and multi drop slave you can jumper positions 1 2 3 4 5 and 6 on the ...

Page 28: ...Duplex mode 2 wire Out Full or Multi drop 4 wire mode 3 RS 485 RTS Termination resistor RS 485 RTS Terminator resistor 150 ohms 4 RS 485 TxD Termination resistor RS 485 TXD Terminator resistor 150 ohms 5 RX485 CTS Bias and Termination network RS 485 CTS Bias and termination Both jumpers must be installed at the same time 6 RX485 CTS Bias and Termination network RS 485 CTS Bias and termination Both...

Page 29: ...pport Example 1 This example shows the settings on jumper blocks JA JB JC JD of the Rear I O Opto so that port 2 is set for RS 232 and ports 1 3 4 are set for RS 422 485 JA 1 2 3 4 5 6 7 8 JB 1 2 3 4 5 6 7 8 JC 1 2 3 4 5 6 7 8 JD 1 2 3 4 5 6 7 8 Port 1 Port 2 Port 3 Port 4 Jumper Legend 1 RS 232 RS 422 485 select 2 RS 422 485 half duplex mode control 3 RTS termination 4 TxD termination 5 CTS termi...

Page 30: ...rt 4 is set for RS 232 JA Jumper Legend 1 RS 232 RS 422 485 select 2 RS 422 485 half duplex mode control 3 RTS termination 4 TxD termination 5 CTS termination 6 CTS termination 7 RxD termination 8 RxD termination 1 2 3 4 5 6 7 8 JB 1 2 3 4 5 6 7 8 JC 1 2 3 4 5 6 7 8 JD 1 2 3 4 5 6 7 8 Port 1 Port 2 Port 3 Port 4 Technical Note Full duplex multi drop slave and half duplex modes apply to RS 422 485 ...

Page 31: ...ation RxD RTS RTS CTS RTS CTS CTS PCI 954 UART 150 Ω 1 8K Ω 1 8K Ω 5 V 150 Ω 1 8K Ω 1 8K Ω 5 V 150 Ω JA4 JB4 JC4 JD4 150 Ω JA3 JB3 JC3 JD3 JA8 JB8 JC8 JD8 JA7 JB7 JC7 JD7 JA6 JB6 JC6 JD6 JA5 JB5 JC5 JD5 10K Ω DTR JA3 JB3 JC3 JD3 Figure 8 RS 422 485 partial schematic for Rear I O Opto Note Line bias termination is jumper selectable ...

Page 32: ...RS 232 and therefore should not be terminated JA 1 2 3 4 5 6 7 8 JB 1 2 3 4 5 6 7 8 JC 1 2 3 4 5 6 7 8 JD 1 2 3 4 5 6 7 8 Port 1 Port 2 Port 3 Port 4 Jumper Legend 1 RS 232 RS 422 485 select 2 RS 422 485 half duplex mode control 3 RTS termination 4 TxD termination 5 CTS termination 6 CTS termination 7 RxD termination 8 RxD termination Technical Notes 1 For full duplex half duplex and multi drop sl...

Page 33: ...es Figure 8 depicts a 4 wire cabling scheme between a port on the Titan cPCI adapter to a port on the RS 422 485 peripheral Figure 9 RS 422 485 wiring diagram 4 wire RTS RTS CTS CTS TxD TxD RxD RxD RxD TxD RxD TxD RTS CTS RTS CTS SR SR Titan cPCI adapter RS 485 peripheral 3 4 2 5 6 9 7 8 1 Technical Tip The RS 422 485 electrical interface consists of a differential signaling scheme You should alwa...

Page 34: ...rt on the RS 422 485 peripheral Figure 10 RS 422 485 wiring diagram 2 wire RTS RTS CTS CTS TxD TxD RxD RxD RxD TxD RxD TxD RTS CTS RTS CTS SR SR Titan cPCI adapter RS 485 peripheral 3 1 4 2 5 6 9 7 8 Technical Tip The RS 422 485 electrical interface consists of a differential signaling scheme You should always connect the signals with twisted pairs ...

Reviews: