CAUTIONS

Use cautions when mounting components to surfaces 
that may have concealed wiring beneath the surface.

Turn off power to HVAC equipment before installing or 
servicing airflow controls.

Read and follow all instructions carefully.

Follow all local electrical codes during installation. All 
wiring must conform to local and national electrical 
codes.

Read entire manual before installing products.

Installation should be performed by a qualified 
individual with sufficient experience and skill.

!

The WLDCK Kit includes:

Wireless Direct Damper Control

Installation Manual

Model WLDCK

Patent US 10,520,212 B1

WLDC Wireless Damper Control.

DDC2 Damper Control Module. 

The WLDC is prelinked to the DDC2 and automatically 
links when powered.

Connect the DDC2 Damper Control to R and C terminals at the 
equipment using 2 conductor, 18 or 20 ga. thermostat cable.

Step 2. Wire the DDC2 to the Equipment

The DDC2 Damper Control is installed near the HVAC 
equipment on a non-metal surface using the hardware kit.

Step 1. Install the DDC2 Damper Control

To remove the cover, press the 
plastic tabs in the area indicated. 

HVAC 
System

DDC2

Damper Control

R
C

R
C

(1) CR2450 Coin Cell Battery.

Not intended as a zoning system. See eControlsUSA.com for
zoning solutions.

Compatible with R80CJ-XX Dampers (unsealed) or 
R80JZD-XX Dampers (sealed).

Damper sold separately.

Made 
in the 

USA

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.

Contains Transmitter Module
FCC ID OA3MRF89XAM9A

Wireless Damper Control
24VAC, 4VA

eControls, Inc., Laguna Hills, CA 
eControlsUSA.com

Patent US 10,520,212 B1

Model DDC2

WLDC Wireless Damper Control Wiring Diagram

WLDC Wireless Damper Control

Installed on any wall.

Wireless

DDC2 Damper Control Module

Installed near equipment

Made 
in the 

USA

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.

Contains Transmitter Module
FCC ID OA3MRF89XAM9A

Wireless Damper Control
24VAC, 4VA

eControls, Inc., Laguna Hills, CA 
eControlsUSA.com

Patent US 10,520,212 B1

Model DDC2

2

R80CJ or R80JZD Damper.

 Installed in the duct 

controlling airflow to the space.

Plug&Play Cable Included

IN

OUT

IN

To 24VAC (R and C)
at the equipment or
24VAC, 40VA transformer.

Made 
in the 

USA

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.

Contains Transmitter Module
FCC ID OA3MRF89XAM9A