Page 1: ...WWW CLF LIGHTING COM manual LED WASH RGBW XL V1 0 2017 JANUARY ...

Page 2: ...a link 6 Tips for reliable data transmission 6 Physical installation 7 Fastening the fixture to a flat surface 7 Setup 8 Control panel and menu navigation 8 DMX address setting 8 Control Mode 8 Static Color options 9 Auto Show 9 Master Slave 9 ID Address Instructions 10 Setting 12 Custom program 12 Lock 12 DMX protocols 13 Onboard control menus 18 Blow out Diagram 19 Specifications 20 ...

Page 3: ...Dimensions All dimensions are in millimeters WWW CLF LIGHTING COM 1 0 153 125 150 483 478 ...

Page 4: ... protection Before using the fixture check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Power input and through out cables must be rated 20A minimum have three conductors 1 5 mm 16 AWG minimum conductor size and an outer cable diameter of 5 15 mm Cables must be hard usage type SJT or equivalent and heat re...

Page 5: ...o not use fixture on a dimmer Do not look continuously at LEDs from a distance of less than 3 meters from the front surface of the fixture without protective eyewear such as shade 4 5 welding goggles At less than this distance the LED emission can cause eye injury or irritation At distances of 3 meters and above light output is harmless to the naked eye provided that the eye s natural aversion res...

Page 6: ...WWW CLF LIGHTING COM 4 0 fixture overview G Clamp with Quicklock 875760 Optional 5PIN DMX IN 5PIN DMX OUT 3PIN DMX IN 3PIN DMX OUT MAINS IN MAINS OUT Display ...

Page 7: ...e grounded earthed The power distributioncircuit must be equipped with a fuse or circuit breaker and ground fault earth fault protection Warning Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixtures can easily be disconnected from power Important Do not insert or remove live connectors to apply or...

Page 8: ...irst fixture to AC mains power connectors must be used to draw AC mains power from the fixtures power throughput sockets and yellow connectors must be used to supply power at the fixture s power input sockets No matter what the AC mains power voltage is do not connect more than ten the fixture in total i e including the first fixture to AC mains power in one interconnected daisy chain using power ...

Page 9: ...mes the weight of all fixtures and equipment to be installed on it Warning The supporting surface must be hard and flat or air vents in the base may be blocked which will cause overheating Fasten the fixture securely Do not stand it on a surface or leave it where it can be moved or can fall over Attach a securely anchored safety cable to the safety cable attachment point see Fixture overview on pa...

Page 10: ...g Control mode 15 f The DMX address also known as the start channel is the first channel used to receive instructions from the controller For independent control each fixture must be assigned its own control channels The DMX address is configured using the DMX ADDRESS menu in the control panel For setting the DMX address press ENTER before you can change the adddres 1 DMX operate mode setting Acce...

Page 11: ... 9 19 Programe 9 pre programmed 9 10 Auto 10 AUTO 1 10 cycle program 20 Programe 10 pre programmed 10 Master Slave 1 Master Slave operate mode setting Access control panel function by pressing MODE until RUN is displayed Press ENTER press UP DOWN buttons until the SLAV is displayed Press ENTER Press MODE return to MENU 2 Upload custom program or set to another fixture Set all the fixtures which re...

Page 12: ...pendent DMX512 ID ADDRESS SELECTION DMX VALUE FUNCTION DMX VALUE FUNCTION DMX VALUE FUNCTION 000 009 All IDs 212 ID23 235 ID46 010 019 ID1 213 ID24 236 ID47 020 029 ID2 214 ID25 237 ID48 030 039 ID3 215 ID26 238 ID49 040 049 ID4 216 ID27 239 ID50 050 059 ID5 217 ID28 240 ID51 060 069 ID6 218 ID29 241 ID52 070 079 ID7 219 ID30 242 ID53 080 089 ID8 220 ID31 243 ID54 090 099 ID9 221 ID32 244 ID55 100...

Page 13: ...dress The three units have different ID addresses In the DMX address 001 the user can control the first three lights simultaneously When using channel 16 select the channel number is 020 029 and ID Address 02 the controller can control the second light individually When using channel 16 select the channel number is 000 010 and ID Address 00 all the lights are in common use at the same DMX address ...

Page 14: ...00 255 B000 blue 000 255 Pr10 SC01 90 W000 White 000 255 S000 Strobe 00 20 T000 Step Time 000 255 CUSTOM SCENE F000 Transition Time Of Last Step To Current Step Custom program EDIT PRXX SC01 1 Press MODE button until EDIT is displayed press ENTER access program mode 2 Select the program you ll edit by pressing UP DOWN buttons The available range is o1 10 3 Select the step you ll edit by pressing U...

Page 15: ...0 100 6 Strobe 000 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 185 189 190 204 205 209 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast...

Page 16: ...5 149 150 164 165 169 170 184 185 189 190 204 205 209 210 224 225 229 230 244 245 255 Shutter open Strobe 1 fast slow Shutter open Strobe 2 opening pulse fast slow Shutter open Strobe 3 closing pulse fast slow Shutter open Strobe 4 random strobe fast slow Shutter open Strobe 5 random opening pulse fast slow Shutter open Strobe 6 random closing pulse fast slow Shutter open Strobe 7 burst pulse fast...

Page 17: ...Strobe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast slow Shutter open Strobe 10 burst fast slow Shutter open 7 Dimmer 2 000 255 BAR 2 0 100 Dimmer 8 Red 2 000 255 BAR 2 Red 0 100 9 Green 2 000 255 BAR 2 Green 0 100 10 Blue 2 000 255 BAR 2 Blue 0 100 11 White 2 000 255 BAR 2 White 0 100 12 Strobe 2 000 024 025 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 14...

Page 18: ...robe 8 random burst pulse fast slow Shutter open Strobe 9 sine wave fast slow Shutter open Strobe 10 burst fast slow Shutter open 7 Dimmer 2 000 255 BAR 2 0 100 Dimmer 8 Red 2 000 255 BAR 2 Red 0 100 9 Green 2 000 255 BAR 2 Green 0 100 10 Blue 2 000 255 BAR 2 Blue 0 100 11 White 2 000 255 BAR 2 White 0 100 12 Strobe 2 000 255 BAR 2 Strobe Strobe 1 Please refer to 13 Color wheel 000 255 Macro color...

Page 19: ...100 3 Value 000 255 0 100 Note In HSV mode Hue stands for the visible light such as red yellow and cyan etc Saturation refers to the dominance of hue in the color when saturation is at 100 then the color is at its purest Value is the color s brightness when value is at 100 then the color is at its brightest ...

Page 20: ...B 255 000 Blue W 255 000 White S 20 00 Strobe 6 AUTO At00 01 10 10 auto programs available Pr00 01 10 Chose program from 10 EDIT programs 7 EDIT PR01 09 Pr10 Custom Custom SC01 30 SC01 90 Scene Scene R000 Red 000 255 G000 Green 000 255 B000 Blue 000 255 W000 White 000 255 S000 Strobe 000 255 T000 Step Time 000 255 F000 Transition Time Of Last Step To Current Step 8 SET KEY ON OFF MODE UP MODE DOWN...

Page 21: ...7 20 Fan 005512 5 Left bearing 011243 21 Driver board 005265 6 Left flange 011245 22 Power supply 008221 7 Side parts of radiators 011224 23 Housing 011504 8 Radiators 011222 24 Left Side parts of housing 011511 9 Scrub Cover acry 011231 25 Knob 008095 10 50 lens holder 011229 26 Power in 005358 11 50 lens 007051 27 3PIN 5PIN XLR input 005374 12 Led board 012057 28 Display cover 011434 13 Right fl...

Page 22: ...ials 100 mm from fixture Minimum distance to illuminated surfaces 200 mm from fixture Connections AC power input PowerCON input socket AC power throughput PowerCON output socket DMX data in out 5 pin 3 pin locking XLR Electrical AC power 100 240 V nominal 50 60 Hz Maximum total power consumption 130 W Power supply unit Auto ranging electronic switch mode Power consumption all effects static zero l...