background image

1

CLEARSPAN

 END WALL FRAMING KITS

Revision date: 11.12.14

©2014 ClearSpan™

All Rights Reserved. Reproduction 

is prohibited without permission.

STK#

108986 

End Frame Kit

ClearSpan

 End Frame Kit 

36' Wide x 16' 2" High

Rafter is not included with kit. Customer supplies the concrete to secure the 2" x 2" tubing.

Summary of Contents for 108986

Page 1: ... 11 12 14 2014 ClearSpan All Rights Reserved Reproduction is prohibited without permission STK 108986 End Frame Kit ClearSpan End Frame Kit 36 Wide x 16 2 High Rafter is not included with kit Customer supplies the concrete to secure the 2 x 2 tubing ...

Page 2: ...g the instructions as presented will help ensure the proper assembly of your end wall The steps outlining the assembly process are as follows 1 Verify that all parts are included in the shipment Notify Customer Service for questions or concerns 2 Read these instructions the Must Read document and all additional documentation included with the shipment before you begin assembling the end wall 3 Gat...

Page 3: ...nstallation steps these instructions describe installing an optional end panel Additional purchase required The components used to install the optional end panel are also described and shown during the procedure Some components may differ from what is shown Contact your sale representative to purchase an end panel with end panel installation kit if desired ATTENTION Some of these instructions may ...

Page 4: ...equipped ATTENTION End frame spacing depends on the door sizes and may differ from what is shown in these diagrams Consult the End Wall diagrams in the Quick Start section for pipe identifications and locations If you are installing an overhead door do not attach end framing within the door opening Additional purchase required for end panel and doors ground level ATTENTION The QH1330 bracket shown...

Page 5: ...s for the door if equipped The width of the door determines the frame dimensions for the door opening Consult the documentation sent with the door for the correct spacing of the door jambs 3 Dig a 12 diameter hole at the locations found in previous step to a depth that is below the geographic frost line ATTENTION Concrete should remain 1 to 2 below ground level so that it does not interfere with c...

Page 6: ...overing the end frame with something other than an end panel install that material now and then secure the main cover of the shelter 5 Plumb the vertical frame tube and use wooden stakes or other means to anchor it in place 6 Repeat the steps to construct attach and set the remaining end frame tubes 7 Verify that all end frame tubes are plumb and spaced as needed 8 Add concrete to each hole and al...

Page 7: ...lowing a few feet to remain between the straps Outside of the End Panel DO NOT ATTEMPT TO PULL THE END PANEL INTO POSITION ON WINDY OR STORMY DAYS 3 With the temporary straps or customer supplied rope in place pull the end panel up to the end rafter and secure the end panel to the end rafter using small sections of the strap Keep the panel centered End Panel Main Cover Strap in D ring Top Chord of...

Page 8: ...d panel The end panel flap that extends beyond the D rings is tucked between the rafter and the main cover DO NOT attach the flap to the end rafter at this time 5 Stretch the bottom of the end panel evenly out on the ground along the bottom frame tube of the end wall frame if needed and tighten the 1 strap at the top of the end panel Top of end panel must remain as close to the rafter as possible ...

Page 9: ...e pocket and to remove it from the opening 1 Locate the 1 315 pipes and assemble sections to achieve the required length Cut to length if needed 2 Secure each pipe joint with a Tek screw Wrap joint and screw with duct tape to prevent end panel damage 3 Insert assembled conduit into horizontal end panel pocket End wall and panel shown are used for illustration only These may differ from actual item...

Page 10: ...stalling doors 1 Working from inside the frame mark a 12 16 border along the door jambs and below the header Consult the diagram below These 12 16 flaps are wrapped around the door framing and secured to the inside of the door frame once the final diagonal cuts are made 2 Using the diagram as a guide cut the end panel to remove the section that is shaded Diagram above shows the end wall and end pa...

Page 11: ...nel to the inside or backside of the door frame tubes Some doors kits use this surface for tracks and brackets Check the instructions that shipped with the door for additional details 2 Repeat the steps to install the end wall and end panel for the remaining end of the building if equipped 3 Install the door or doors according to the instructions included with those components 4 After doors are in...

Page 12: ...2 Locate the four ratchets and attach each ratchet to the outside of the end frame base rail if equipped using a Tek screw FA4482B Use the cover strap to position the ratchet 3 Locate straps at the front and rear of main cover and feed straps through center slot in each end ratchet 4 Tighten end ratchets to secure bonnet portion of the main cover 5 Move to the other end of the building and secure ...

Page 13: ... worn or damaged parts immediately Check all fasteners frequently to verify that these remain tight and in good repair Do not climb or stand on the building or frame at anytime Remove debris and objects that may accumulate on the shelter Use tools that will not damage the cover when removing debris Remove snow to prevent excess accumulation Use tools that will not damage the cover when removing sn...

Page 14: ...te 11 12 14 QUICK START GUIDE 36 W x 16 2 H End Frame Kit The end frame kit does not include the end rafter or end panel as shown in the diagram below End frame shown may differ from the actual end frame Customer supplied Concrete Pier Ground Level ...

Page 15: ...1330 QH1330 QH1330 QH1330 QH1330 QH1330 105328 Cut to Fit 105328 Cut to Fit 105328 105328 105328 105328 6 on center 6 on center 6 on center 6 on center 6 on center 6 on center QH1330 The spacing show may differ from spacing of actual end wall The spacing of individual end frame members and the size of the door opening depends on door if equipped If doors are to be installed frame end wall as neede...

Page 16: ... Rafter Anchor to site or concrete piers G r o u n d L e v e l 105328 Cut to fit QH1330 105328 Cut to Fit 105328 104075 Tek Screws 105328 QH1330 ATTENTION For treated wood post piers secure end frame tubes using QH1330 brackets and the appropriate customer supplied fasteners ...

Page 17: ...r supplied carriage bolts and nuts in the locations shown in the diagram below END WALL SPECIAL NOTE If no door is to be installed in the end wall attach square tubing using the QH1330 brackets in the areas identified by the dashed line below Install square tube at the center of the opening when no door is installed Remove this frame tube and use for a header tube to install a door This tube is cu...