background image

Catalyst Digital Building Series Switch Hardware Installation Guide

First Published: 

2017-05-19

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
       800 553-NETS (6387)
Fax: 408 527-0883

Summary of Contents for CDB-8P

Page 1: ...Series Switch Hardware Installation Guide First Published 2017 05 19 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Page 2: ...e encouraged to try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product no...

Page 3: ...abit Uplink Ports 5 Console Ports 5 USB Type A Port 6 SD Flash Memory Card Slot 6 LEDs 6 Downlink Port Data LEDs 8 Downlink Port PoE LEDs 8 Uplink Port Data LEDs 8 System LED 9 Status LED 9 Speed LED 10 Power Save LED 10 Mode Button 10 Rear Panel 11 Network Configurations 12 C H A P T E R 2 Switch Installation 13 Safety Warnings 13 Box Contents 15 Catalyst Digital Building Series Switch Hardware I...

Page 4: ... Wired Junction Box 63 Flexible Mount with IEC C14 Power Junction Box 65 Rack Mounting 66 Establishing the System Ground 73 Required Tools and Equipment 74 Connecting the System Ground 74 Installing the Power Cord Retainer 75 10 100 Port Connections 79 C H A P T E R 3 Troubleshooting 81 Diagnosing Problems 81 Switch POST Results 81 Switch LEDs 81 Switch Connections 81 Bad or Damaged Cable 81 Ether...

Page 5: ...ation Setup Wizard 93 Completing the Configuration Setup Wizard 94 Configuring the Switch Using the CLI 95 Accessing the CLI Through the Console Port 95 Connecting the RJ 45 Console Port 95 Connecting the USB Console Port 95 Installing the Cisco Microsoft Windows USB Device Driver 96 Installing the Cisco Microsoft Windows XP USB Driver 96 Installing the Cisco Microsoft Windows 2000 USB Driver 97 I...

Page 6: ...Using the Smartphone App 99 Catalyst Digital Building Series Switch Hardware Installation Guide vi Contents ...

Page 7: ...t bold font Document titles new or emphasized terms and arguments for which you supply values are in italic font Italic font Terminal sessions and information the system displays appear in courier font Courier font Bold Courier font indicates text that the user must enter Bold Courier font Elements in square brackets are optional x An ellipsis three consecutive nonbolded periods without spaces aft...

Page 8: ...r take note Notes contain helpful suggestions or references to material not covered in the manual Note Means the following information will help you solve a problem Tip Means reader be careful In this situation you might do something that could result in equipment damage or loss of data Caution Means the described action saves time You can save time by performing the action described in the paragr...

Page 9: ...documentation at http www cisco com c en us td docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are a free service and Cisco currently supports RSS version 2 0 Catalyst Digital Building Series Switch Hardware Install...

Page 10: ...Catalyst Digital Building Series Switch Hardware Installation Guide x Preface Obtaining Documentation and Submitting a Service Request ...

Page 11: ...ding controls in an enterprise carpeted space Cisco Catalyst Digital Building Series Switches enable and drive this convergence of smart lighting and building systems to IP over PoE technology Cisco Catalyst Digital Building Series Switches provide support for the following features Eight Fast Ethernet downlink ports Two Gigabit Ethernet uplinks Power over Ethernet Plus PoE support up to 240W of P...

Page 12: ... components of a Catalyst Digital Building Series Switch Catalyst Digital Building Series UPOE Switch Catalyst Digital Building Series PoE PoE Switch Eight downlink Fast Ethernet UPOE ports Eight downlink Fast Ethernet PoE ports Two copper uplink Gigabit Ethernet ports Two copper uplink Gigabit Ethernet ports Mode button Mode button RJ 45 console port RJ 45 console port USB micro Type B console po...

Page 13: ...PoE ports 1 Downlink port Data and PoE LEDs 7 Uplink Gigabit Ethernet ports 2 Uplink port data LEDs 8 USB micro Type B console port 3 System LEDs 9 USB Type A port 4 Mode button 10 RJ 45 Console port 5 Catalyst Digital Building Series Switch Hardware Installation Guide 3 Product Overview Front Panel ...

Page 14: ...Mode button 10 RJ 45 Console port 5 PoE PoE and UPOE Ports The ports on the PoE PoE switch provide PoE support for devices compliant with IEEE 802 3af and IEEE 802 3at and also provide PoE support for Cisco IP Phones and LED Luminaries The PoE switch ports are Power Source equipment PSE capable and source power to PD devices Luminaries connected to the Catalyst Digital Building Series Switch Hardw...

Page 15: ...the console port for operation with Microsoft Windows Mac OS X or Linux do not require special drivers This illustration shows a 5 pin micro Type B USB port Figure 3 USB Micro Type B Port With the Cisco Windows USB device driver you can connect and disconnect the USB cable from the console port without affecting Windows HyperTerminal operations The console output always goes to both the RJ 45 and ...

Page 16: ... the flash device with a FAT file system The port supports USB Bluetooth devices The USB Bluetooth device acts as a Bluetooth host and serves as either a serial port or a management port connection You can pair it with your Bluetooth smart phone laptop or tablet SD Flash Memory Card Slot The switch supports a Secure Digital SD flash memory card that makes it possible to replace a failed switch wit...

Page 17: ...ort mode Figure 4 Switch LEDs and Mode Button STATUS LED 5 Downlink Port PoE LEDs 1 MODE button 6 Downlink Port Data LEDs 2 POWER SAVE LED 7 Uplink Port Data LEDs 3 SYSTEM LED 8 SPEED LED 4 Catalyst Digital Building Series Switch Hardware Installation Guide 7 Product Overview LEDs ...

Page 18: ...rs and alignment and jabber errors are monitored for link faults Blinking green amber Port is blocked by Spanning Tree Protocol STP and is not forwarding data After a port is reconfigured the port LED is amber for up to 30 seconds as STP searches for loops Amber Downlink Port PoE LEDs Description Color PoE is not enabled Off PoE is enabled Ports are functioning correctly Green PoE port has been de...

Page 19: ...ol STP and is not forwarding data After a port is reconfigured the port LED is amber for up to 30 seconds as STP searches for loops Amber System LED System Status Color System is not powered on Off System is operating normally Green System is receiving power but is not operating properly Amber Status LED Description Color Status Mode disabled Off Status Mode Enabled Port LEDs function as described...

Page 20: ...er When the mode button is pressed the LEDs turn on for a set period 60 seconds before they turn off again to save power This can be overridden by a configuration parameter which alters the default 60 second timeout or disables LED power savings completely All LEDs are affected by this function except the System LED which only dims and does not turn off completely Action Duration System State Acti...

Page 21: ...tch Proprietary power connector 1 You should mount the switch in one of the following mount accessories and complete the electrical installation to power on the switch Note Flexible mount with IEC C14 power junction box CDB MNT FLEX C14 Flexible mount with direct wired junction box CDB MNT FLEX DIR Plenum rated 5RU 19 rack mount chassis for up to 5 switches CDB MNT RACK5 C14 Catalyst Digital Build...

Page 22: ...guration concepts and examples of using the switch to create dedicated network segments and interconnecting the segments through Fast Ethernet and Gigabit Ethernet connections Catalyst Digital Building Series Switch Hardware Installation Guide 12 Product Overview Network Configurations ...

Page 23: ...9 Safety Warnings This section includes the warning statements relating to basic installation Read this section before you start the installation procedure Do not work on the system or connect or disconnect cables during periods of lightning activity Statement 1001 Warning Read the installation instructions before connecting the system to the power source Statement 1004 Warning Catalyst Digital Bu...

Page 24: ...nt 1024 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Warning Do not use this product near water for example near a bath tub wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool Statement 1035 Warning Ultimate disposal of this product should be handled according to all national laws and regulati...

Page 25: ...rs and service people who are authorized within the restricted access location are made aware of the hazard A restricted access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1072 Warning No user serviceable parts inside Do not open Statement 1073 Warning Installation of the equipment must comply with local and national electrical code...

Page 26: ...010 3 et 12 100 du Code Canadien de l électricité Première partie CSA C22 1 Suitable for use in environmental air space in accordance with Section 300 22 C of the National Electrical Code and Sections 2 128 12 010 3 and 12 100 of the Canadian Electrical Code Part 1 CSA C22 1 Mounting Accessories This section lists the contents of the shipping box for mounting accessories Figure 6 Box Contents Flex...

Page 27: ...y specific power cord are supplied in a separate accessory kit if ordered Note Figure 7 Box Contents Flexible mount with direct wired junction box Four 1 4 mounting screws 48 101572 01 3 CDB MNT FLEX DIR 1 Compliance documentation 78 17985 01 4 Two U shaped mounting brackets 700 112420 01 2 Catalyst Digital Building Series Switch Hardware Installation Guide 17 Switch Installation Mounting Accessor...

Page 28: ...0828 01 7 Eight number 10 Phillips pan head screws 48 0627 01 3 Optional Country specific power cord 8 Dual hole ground lug 32 0619 01 4 Country specific power cord can be ordered separately if required Note Installation Guidelines Supported Hardware Bluetooth dongles with the following chipset are supported Catalyst Digital Building Series Switch Hardware Installation Guide 18 Switch Installation...

Page 29: ...s and fluorescent lighting fixtures Make sure that the cabling is safely away from other devices that might damage the cables Airflow around the switch is unrestricted For 10 100 and 1 Gigabit Ethernet ports the cable length from a switch to a connected device cannot exceed 328 feet 100 meters Rack Mounting Guidelines 5RU 19 rack mount chassis CDB MNT RACK5 C14 can only be installed in standard 19...

Page 30: ...ctly on a surface care must be taken to choose fasteners that can safely hold the switch and mounting hardware which weighs 15 lbs 6 8 kg under all use conditions Maintain 3 inch of space to any surface above the flexible mount to allow proper cooling Only a trained and qualified electrician should be allowed to complete the wiring of the direct wired junction box CDB MNT FLEX DIR All power connec...

Page 31: ...lexible mount with IEC C14 power junction box Front view Figure 10 Flexible mount with IEC C14 power junction box Rear view IEC C14 power connector 1 Catalyst Digital Building Series Switch Hardware Installation Guide 21 Switch Installation Flexible Mounting ...

Page 32: ... Front view Figure 12 Flexible mount with direct wired junction box Rear view Direct wired junction box 1 1 2 knockout 2 3 4 knockout 3 The mounting procedure includes two types of installations Catalyst Digital Building Series Switch Hardware Installation Guide 22 Switch Installation Flexible Mounting ...

Page 33: ...es of mounting are described in detail in the sections below You can use these mounting positions to install the switch in a flexible mount Horizontal Mounting Vertical Mounting Wall Mount Figure 13 Mounting Orientations for Cisco Catalyst Digital Building Series Switch Catalyst Digital Building Series Switch Hardware Installation Guide 23 Switch Installation Flexible Mounting ...

Page 34: ... Installation section before you start the installation procedure Note Before You Begin Refer to Installation Guidelines section Refer to Electrical Installation section if you are using the flexible mount with direct wired junction box CDB MNT FLEX DIR Review the following illustrations and tables Figure 14 Mounting Bracket Detail 1 4 hole for attaching to strut channel 1 3 8 hole for attaching t...

Page 35: ...t channel nut slides is inserted into the channel and held by a spring or a plastic cone The bracket acts as an integrated washer So strut washer is not required Matching bolt is fed from below into the strut channel nut Catalyst Digital Building Series Switch Hardware Installation Guide 25 Switch Installation Flexible Mounting ...

Page 36: ...ting holes on the bracket to the holes on the flexible mount and attach them to the mount with the 1 4 mounting screws supplied Figure 16 Attaching mounting brackets to the flexible mount Catalyst Digital Building Series Switch Hardware Installation Guide 26 Switch Installation Flexible Mounting ...

Page 37: ... the mounting bracket to the strut nut hole on the strut channel and secure the bracket to the strut channel using a bolt matching to the strut nut The bolt must match the strut nut Note Catalyst Digital Building Series Switch Hardware Installation Guide 27 Switch Installation Flexible Mounting ...

Page 38: ...unt assembly to strut channel In the following figure 3 8 hole is used to attach the assembly to the strut channel You can also use 1 4 hole to attach the assembly to the strut channel Note Catalyst Digital Building Series Switch Hardware Installation Guide 28 Switch Installation Flexible Mounting ...

Page 39: ...CDB MNT FLEX DIR to a power source use an armored cable See Electrical Installation section CDB MNT FLEX DIR accepts 100V 277V AC Input To connect the assembly which uses flexible mount with IEC C14 power junction box CDB MNT FLEX C14 to a power source use country specific power cord Catalyst Digital Building Series Switch Hardware Installation Guide 29 Switch Installation Flexible Mounting ...

Page 40: ...ing Figure 18 Inserting switch into flexible mount assembly Horizontal Mounting Overmount To install the Catalyst Digital Building Series Switch in a flexible mount in horizontal overmount orientation follow these steps If you are using the flexible mount with a direct wired junction box CDB MNT FLEX DIR refer to the Electrical Installation section before you start the installation procedure Note ...

Page 41: ...Figure 19 Mounting Bracket Detail 1 4 hole for attaching to strut channel 1 3 8 hole for attaching to strut channel 2 Mounting screw holes 3 Catalyst Digital Building Series Switch Hardware Installation Guide 31 Switch Installation Flexible Mounting ...

Page 42: ...t channel nut slides is inserted into the channel and held by a spring or a plastic cone The bracket acts as an integrated washer So strut washer is not required Matching bolt is fed from below into the strut channel nut Catalyst Digital Building Series Switch Hardware Installation Guide 32 Switch Installation Flexible Mounting ...

Page 43: ...ting holes on the bracket to the holes on the flexible mount and attach them to the mount with the 1 4 mounting screws supplied Figure 21 Attaching mounting brackets to the flexible mount Catalyst Digital Building Series Switch Hardware Installation Guide 33 Switch Installation Flexible Mounting ...

Page 44: ... the mounting bracket to the strut nut hole on the strut channel and secure the bracket to the strut channel using a bolt matching to the strut nut The bolt must match the strut nut Note Catalyst Digital Building Series Switch Hardware Installation Guide 34 Switch Installation Flexible Mounting ...

Page 45: ...CDB MNT FLEX DIR to a power source use an armored cable See Electrical Installation section CDB MNT FLEX DIR accepts 100V 277V AC Input To connect the assembly which uses flexible mount with IEC C14 power junction box CDB MNT FLEX C14 to a power source use country specific power cord CDB MNT FLEX C14 accepts 100V 240V AC Input Step 5 Slide the switch into the flexible mount in a front mounting pos...

Page 46: ...xed Vertical Mount To install a Catalyst Digital Building Series Switch in a flexible mount in fixed vertical mounting orientation follow these steps If you are using the flexible mount with a direct wired junction box CDB MNT FLEX DIR refer to the Electrical Installation section before you start the installation procedure Note Before You Begin Refer to Installation Guidelines section Refer to Ele...

Page 47: ... tables Figure 24 Mounting Bracket Detail 1 4 hole for attaching to strut 1 3 8 hole for attaching to strut 2 Mounting screw holes 3 Catalyst Digital Building Series Switch Hardware Installation Guide 37 Switch Installation Flexible Mounting ...

Page 48: ...t channel nut slides is inserted into the channel and held by a spring or a plastic cone The bracket acts as an integrated washer So strut washer is not required Matching bolt is fed from below into the strut channel nut Catalyst Digital Building Series Switch Hardware Installation Guide 38 Switch Installation Flexible Mounting ...

Page 49: ...ounting brackets to both sides of the flexible mount and attach them to the mount with the 1 4 mounting screws supplied Figure 26 Attaching mounting brackets to the flexible mount Catalyst Digital Building Series Switch Hardware Installation Guide 39 Switch Installation Flexible Mounting ...

Page 50: ...e strut nut hole on the strut channel and secure the bracket to the strut channel using a bolt matching to the strut nut The bolt must match the strut nut Note Repeat the step to attach the other bracket to the strut channel Catalyst Digital Building Series Switch Hardware Installation Guide 40 Switch Installation Flexible Mounting ...

Page 51: ...ce use an armored cable See Electrical Installation section CDB MNT FLEX DIR accepts 100V 277V AC Input To connect the assembly which uses flexible mount with IEC C14 power junction box CDB MNT FLEX C14 to a power source use country specific power cord CDB MNT FLEX C14 accepts 100V 240V AC Input Step 5 Slide the switch into the flexible mount in a front mounting position as shown in the figure and...

Page 52: ...le switches use top vertical mounting orientation as described in Top Vertical Mount Warning Figure 28 Inserting switch into flexible mount assembly Top Vertical Mount To install a single Catalyst Digital Building Series Switch in a flexible mount in top vertical mounting orientation follow these steps Catalyst Digital Building Series Switch Hardware Installation Guide 42 Switch Installation Flexi...

Page 53: ...uidelines section Refer to Electrical Installation section if you are using the flexible mount with direct wired junction box CDB MNT FLEX DIR Review the following illustrations and tables Figure 29 Mounting Bracket Detail 1 4 hole for attaching to strut 1 3 8 hole for attaching to strut 2 Mounting screw holes 3 Catalyst Digital Building Series Switch Hardware Installation Guide 43 Switch Installa...

Page 54: ...t channel nut slides is inserted into the channel and held by a spring or a plastic cone The bracket acts as an integrated washer So strut washer is not required Matching bolt is fed from below into the strut channel nut Catalyst Digital Building Series Switch Hardware Installation Guide 44 Switch Installation Flexible Mounting ...

Page 55: ...he mounting bracket to one side of the flexible mount and attach it to the mount with the 1 4 mounting screws supplied Figure 31 Attaching mounting brackets to the flexible mount Catalyst Digital Building Series Switch Hardware Installation Guide 45 Switch Installation Flexible Mounting ...

Page 56: ...Catalyst Digital Building Series Switch Hardware Installation Guide 46 Switch Installation Flexible Mounting ...

Page 57: ... strut nut The bolt must match the strut nut Note Repeat the step to attach the other bracket to the strut channel Figure 32 Attaching flexible mount assembly to strut channel In the following figure 3 8 hole is used to attach the assembly to the strut channel You can also use 1 4 hole to attach the assembly to the strut channel Note Catalyst Digital Building Series Switch Hardware Installation Gu...

Page 58: ... FLEX DIR accepts 100V 277V AC Input To connect the assembly which uses flexible mount with IEC C14 power junction box CDB MNT FLEX C14 to a power source use country specific power cord CDB MNT FLEX C14 accepts 100V 240V AC Input Step 5 Slide the switch into the flexible mount in a front mounting position Catalyst Digital Building Series Switch Hardware Installation Guide 48 Switch Installation Fl...

Page 59: ...g Warning Figure 33 Inserting switch into flexible mount assembly Top Vertical Mount with two Flexible Mounts Use the following procedure to attach two flexible mounts together Catalyst Digital Building Series Switch Hardware Installation Guide 49 Switch Installation Flexible Mounting ...

Page 60: ...nt into the corresponding four slots of the other flexible mount at once Following figures show the location of tabs and slots on the flexible mount Figure 34 Tabs at the bottom of the flexible mount Tabs 1 Catalyst Digital Building Series Switch Hardware Installation Guide 50 Switch Installation Flexible Mounting ...

Page 61: ...Figure 35 Slots at the top of the flexible mount Slots 1 Catalyst Digital Building Series Switch Hardware Installation Guide 51 Switch Installation Flexible Mounting ...

Page 62: ...Figure 36 Joining two flexible mounts Tabs and slots locked together 1 Catalyst Digital Building Series Switch Hardware Installation Guide 52 Switch Installation Flexible Mounting ...

Page 63: ...ckets and attach them to the flexible mount using the 1 4 mounting screws Figure 37 Attaching two flexible mounts Catalyst Digital Building Series Switch Hardware Installation Guide 53 Switch Installation Flexible Mounting ...

Page 64: ...Catalyst Digital Building Series Switch Hardware Installation Guide 54 Switch Installation Flexible Mounting ...

Page 65: ... nut The bolt must match the strut nut Note Repeat the step to attach the other bracket to the strut channel Figure 38 Attaching combined flexible mount assembly to strut In the following figure 3 8 hole is used to attach the assembly to the strut channel You can also use 1 4 hole to attach the assembly to the strut channel Note Catalyst Digital Building Series Switch Hardware Installation Guide 5...

Page 66: ...ect the assembly which uses flexible mount with IEC C14 power junction box CDB MNT FLEX C14 to a power source use country specific power cord CDB MNT FLEX C14 accepts 100V 240V AC Input Step 5 Slide the switch into the flexible mount in a front mounting position as shown in the figure and tighten thumb screws to secure the switch to flexible mount Catalyst Digital Building Series Switch Hardware I...

Page 67: ...ng switch into flexible mount assembly You can combine multiple flexible mounts together using the above procedure Maximum recommended number of flexible mounts that you can combine together is five Note Catalyst Digital Building Series Switch Hardware Installation Guide 57 Switch Installation Flexible Mounting ...

Page 68: ...ed junction box CDB MNT FLEX DIR refer to the Electrical Installation section before you start the installation procedure Note Before You Begin Refer to Installation Guidelines section Refer to Electrical Installation section if you are using the flexible mount with direct wired junction box CDB MNT FLEX DIR Catalyst Digital Building Series Switch Hardware Installation Guide 58 Switch Installation...

Page 69: ...nting screw holes 3 Procedure Step 1 Place the flexible mount horizontally on a flat surface Step 2 Align mounting brackets to both sides of the flexible mount and attach them to the mount with the 1 4 mounting screws supplied Figure 41 Attaching mounting brackets to the flexible mount Catalyst Digital Building Series Switch Hardware Installation Guide 59 Switch Installation Flexible Mounting ...

Page 70: ...Catalyst Digital Building Series Switch Hardware Installation Guide 60 Switch Installation Flexible Mounting ...

Page 71: ... junction box CDB MNT FLEX DIR to a power source use an armored cable See Electrical Installation section CDB MNT FLEX DIR accepts 100V 277V AC Input To connect the assembly which uses flexible mount with IEC C14 power junction box CDB MNT FLEX C14 to a power source use country specific power cord CDB MNT FLEX C14 accepts 100V 240V AC Input Step 6 Slide the switch into the flexible mount in a fron...

Page 72: ...at can safely hold the switch and mounting hardware which weighs 15 lbs 6 8 kg under all use conditions Note Prohibited Mounting Orientations Following mounting orientations are not allowed These mounting orientations will cause overheating Figure 43 Prohibited Mounting Orientations Catalyst Digital Building Series Switch Hardware Installation Guide 62 Switch Installation Flexible Mounting ...

Page 73: ...sed on the connector type employed in the installation Step 5 Prepare an armored cable by stripping conductor ends approximately 1 2 or 3 4 Step 6 After preparing the cable for connection attach the cable to an approved connector and install the connector in the appropriate knockout Ensure that you leave a sufficient working length of wire inside the junction box Step 7 Strip supply wires Remove p...

Page 74: ...y Rating for Catalyst Digital Building Series PoE PoE Switch Warning 30A 20A 15A Circuit Breaker Rating CDB 8P 24A 16A 12A Circuit Breaker Derating 80 Maximum Current Consumption Nominal Input Voltage 9 6 4 Units Circuit 2 68A 115VAC 18 12 9 Units Circuit 1 34A 230VAC 21 14 10 Units Circuit 1 16A 277VAC Table 3 Switch Ampacity Rating for Catalyst Digital Building Series UPOE Switch 30A 20A 15A Cir...

Page 75: ...ll switches into the mounts and check for proper operation Flexible Mount with IEC C14 Power Junction Box To connect to a power source follow these steps Procedure Step 1 Plug the IEC C14 power cord into the power connector on the flexible mount Step 2 Plug the other end of the power cord into a power source Catalyst Digital Building Series Switch Hardware Installation Guide 65 Switch Installation...

Page 76: ...quires 5RU high 19 inch rack mount chassis CDB MNT RACK5 C14 Figure 44 Front View of Rack Mount Chassis Figure 45 Rear View of Rack Mount Chassis Catalyst Digital Building Series Switch Hardware Installation Guide 66 Switch Installation Rack Mounting ...

Page 77: ...ially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the unit in the rack Statement 1006 Unit in the above warning statement refers to the rack mount chassis CDB MNT RACK5 C14 Note Use the following procedure to install a Catalyst Digital...

Page 78: ...les in the rack Secure the chassis using eight 10 32 or 12 24 screws to the rack post Figure 46 Installation of Rack Mount Chassis on a 19 inch Rack You can also install the rack mount chassis upside down if required for cable routing Catalyst Digital Building Series Switch Hardware Installation Guide 68 Switch Installation Rack Mounting ...

Page 79: ...Catalyst Digital Building Series Switch Hardware Installation Guide 69 Switch Installation Rack Mounting ...

Page 80: ...s to a power source Figure 47 IEC C14 power connector 1 Step 3 Slide the switches into each of the rack unit slots in a front mounting position and secure them to the rack using the supplied screws as shown in the figure Catalyst Digital Building Series Switch Hardware Installation Guide 70 Switch Installation Rack Mounting ...

Page 81: ...Catalyst Digital Building Series Switch Hardware Installation Guide 71 Switch Installation Rack Mounting ...

Page 82: ...st leave 2RU gap between each rack unit for ventilation unless forced air is provided top to bottom in the rack Catalyst Digital Building Series Switch Hardware Installation Guide 72 Switch Installation Rack Mounting ...

Page 83: ... System Ground Establishing the System Ground This section describes how to connect a system ground to the switch The system ground provides additional grounding for EMI shielding requirements and grounding for the low voltage supplies Catalyst Digital Building Series Switch Hardware Installation Guide 73 Switch Installation Rack Mounting ...

Page 84: ... The grounding wire should be sized according to local and national installation requirements The length of the grounding wire depends on the proximity of the chassis to proper grounding facilities No 1 Phillips screwdriver Crimping tool to crimp the grounding wire to the grounding lug Wire stripping tool to remove the insulation from the grounding wire Connecting the System Ground To establish an...

Page 85: ...o metal contact Step 5 Secure the grounding lug to the chassis with two grounding screws Ensure that the grounding lug and the grounding wire will not interfere with other switch hardware or rack equipment Step 6 Connect the other end of the grounding wire to an appropriate grounding point at your site or to the rack Installing the Power Cord Retainer The power cord retainer PWR CLP is optionally ...

Page 86: ... it around the loop on the switch Figure 49 Inserting the Retainer through the Lanced Loop 5RU 19 Rack Mount Chassis Figure 50 Inserting the Retainer through the Lanced Loop Flexible mount with IEC C14 power junction box Sleeve for thinner power cords 3 AC power cord 1 Loop 4 Power cord retainer 2 Catalyst Digital Building Series Switch Hardware Installation Guide 76 Switch Installation Installing...

Page 87: ...19 Rack Mount Chassis Figure 52 Sliding the Retainer Through the Latch Flexible mount with IEC C14 power junction box Latch 3 AC power cord 1 Smaller sleeve for thin power cords 2 Catalyst Digital Building Series Switch Hardware Installation Guide 77 Switch Installation Installing the Power Cord Retainer ...

Page 88: ...r 5RU 19 Rack Mount Chassis Figure 54 Locking the Retainer Flexible mount with IEC C14 power junction box Latch 3 AC power cord 1 Smaller sleeve for thin power cords 2 Catalyst Digital Building Series Switch Hardware Installation Guide 78 Switch Installation Installing the Power Cord Retainer ...

Page 89: ...er 10 100 Port Connections The switch 10 100 port configuration changes to operate at the speed of the attached device If the attached ports do not support autonegotiation you can manually set the speed and duplex parameters Connecting devices that do not autonegotiate or that have the speed and duplex parameters manually set can reduce performance or result in no linkage To maximize performance c...

Page 90: ...egotiate both speed and duplex Set the interface speed and duplex parameters on both ends of the connection Catalyst Digital Building Series Switch Hardware Installation Guide 80 Switch Installation 10 100 Port Connections ...

Page 91: ...rt representative if your switch does not pass POST Switch LEDs If you have physical access to the switch look at the port LEDs for troubleshooting information about the switch See the LED section for a description of the LED colors and their meanings Switch Connections Bad or Damaged Cable Always examine the cable for marginal damage or failure A cable might be just good enough to connect at the ...

Page 92: ...cause one side to show link even though the other side does not have link A port LED that is on does not guarantee that the cable is fully functional The cable might have encountered physical stress that causes it to function at a marginal level If the port LED does not turn on Connect the cable from the switch to a known good device Ensure that both ends of the cable are connected to the correct ...

Page 93: ...he show interfaces privileged EXEC command to see if the interface is error disabled disabled or shutdown on either side of the connection If needed reenable the interface Ping End Device Ping from the directly connected switch first and then work your way back port by port interface by interface trunk by trunk until you find the source of the connectivity issue Make sure that each switch can iden...

Page 94: ...blem with the firmware or software on your NIC You can resolve this by upgrading the NIC driver to the latest version Cabling Distance If the port statistics show excessive FCS late collision or alignment errors verify that the cable distance from the switch to the connected device meets the recommended guidelines Finding the Switch Serial Number If you contact Cisco Technical Assistance you need ...

Page 95: ...1 Serial number 6 Country of Origin 2 CLEI code 7 China Network Access License information 3 MAC address 8 Laser label 4 Catalyst Digital Building Series Switch Hardware Installation Guide 85 Troubleshooting Finding the Switch Serial Number ...

Page 96: ...Catalyst Digital Building Series Switch Hardware Installation Guide 86 Troubleshooting Finding the Switch Serial Number ...

Page 97: ...5 x 8 72 x 11 07 in 6 98 x 22 15 x 28 12 cm CDB 8U 2 75 x 8 72 x 11 07 in 6 98 x 22 15 x 28 12 cm CDB 8P Dimensions H x D x W Environmental Specifications Environmental Ranges 23 to 122 F 5 to 50 C up to 5000 ft 1524 m 23 to 113 F 5 to 45 C up to 10 000 ft 3048 m Operating temperature 1 2 13º to 158ºF 25º to 70ºC up to 15 000 ft 4572 m Storage temperature 5 to 90 noncondensing Operating relative h...

Page 98: ... C may impact service life Power Requirements Power Requirements 100 to 277 VAC 10 CDB 8U 5 18A 115 VAC 2 59A 230 VAC 2 18A 277 VAC CDB 8P 2 68A 115 VAC 1 34A 230 VAC 1 16A 277 VAC AC input voltage 600 W CDB 8U 310 W CDB 8P Power rating3 3 Switch dissipation only excludes PoE which is dissipated at the end device Catalyst Digital Building Series Switch Hardware Installation Guide 88 Technical Spec...

Page 99: ...nector Specifications page 89 Cables and Adapters page 90 Connector Specifications 10 100 1000 Ports Including PoE All 10 100 1000 ports use standard RJ 45 connectors and Ethernet pinouts Figure 58 10 100 1000 Port Pinouts Catalyst Digital Building Series Switch Hardware Installation Guide 89 ...

Page 100: ...c Figure 60 Four Twisted Pair Semi Cross Cable Schematic Figure 61 Two Twisted Pair Straight Through Cable Schematic Figure 62 Two Twisted Pair Crossover Cable Schematic Catalyst Digital Building Series Switch Hardware Installation Guide 90 Connector and Cable Specifications Cables and Adapters ...

Page 101: ...inouts The RS 232 console port uses an 8 pin RJ 45 connector Use an RJ 45 to DB 9 adapter cable to connect the switch console port to a console PC You need to provide a RJ 45 to DB 25 female DTE adapter to connect the switch console port to a terminal Table 4 Console Port Signaling with a DB 9 Adapter Console Device RJ 45 to DB 9 Terminal Adapter Switch Console Port DTE Signal DB 9 Pin Signal CTS ...

Page 102: ...t Signaling with a DB 25 Adapter Console Device RJ 45 to DB 25 Terminal Adapter Switch Console Port DTE Signal DB 25 Pin Signal CTS 5 RTS DSR 6 DTR RxD 3 TxD GND 7 GND GND 7 GND TxD 2 RxD DTR 20 DSR RTS 4 CTS Catalyst Digital Building Series Switch Hardware Installation Guide 92 Connector and Cable Specifications Console Port Adapter Pinouts ...

Page 103: ...r further configuration After you receive the switch from factory when the switch is powered on the first time it will boot in standalone mode In this mode bluetooth is turned on and DHCP server is enabled We recommend you to change the default credentials before deploying in the network once commissioning is complete To start the switch in network mode reload the switch with a new configuration f...

Page 104: ...ce using an Internet browser on your PC type the IP address 10 0 0 1 or 10 0 0 3 in the address bar of your Internet browser if the switch is in network mode and press Enter Type the IP address 172 16 0 1 in the address bar of your Internet browser if the switch is in standalone more and press Enter Step 9 Type the following default credentials username cisco password cisco and press Enter We reco...

Page 105: ...and your PC or terminal possible Step 3 Configure the baud rate and character format of the PC or terminal to match the console port default characteristics 9600 baud 8 data bits 1 stop bit No parity None flow control Step 4 Power on the switch as described in the switch getting started guide Step 5 The PC or terminal displays the bootloader sequence Press Enter to display the setup prompt Connect...

Page 106: ...er to display the setup prompt Follow the steps in the Setup program Installing the Cisco Microsoft Windows USB Device Driver A USB device driver must be installed the first time a Microsoft Windows based PC is connected to the USB console port on the switch Installing the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows 2000 USB Driver Installing the Cisco Microsoft Wi...

Page 107: ...to the PC and the switch console port The USB console port LED turns green and the Found New Hardware Wizard appears Follow the instructions to complete the driver installation Installing the Cisco Microsoft Windows Vista and Windows 7 USB Driver Procedure Step 1 Obtain the Cisco USB console driver file from the Cisco com web site and unzip it You can download the driver file from the Cisco com si...

Page 108: ...en the Remove the Program window appears click Remove Step 5 When the InstallShield Wizard Completed window appears click Finish Using the Add or Remove Programs Utility Before You Begin Disconnect the switch console terminal before uninstalling the driver Procedure Step 1 Click Start Control Panel Add or Remove Programs Step 2 Scroll to Cisco Virtual Com and click Remove Step 3 When the Program M...

Page 109: ...is connected to the network and is ready for day to day usage The network administrator must now move the switch to network mode This will disable Bluetooth Here are some of the features of the app when the switch is in standalone mode Connect to the switch from your smartphone either via Bluetooth or a serial connection View details of the switch such as MAC Address software image version and ope...

Page 110: ... to the switch by going to the Settings option in your smartphone Note If you have an Android device your smartphone should connect to the switch via Classic Bluetooth This can happen only if you connect to the switch from the app and not from the Android Settings option If you have an iOS device your smartphone should connect to the switch via Bluetooth Low Energy This can happen only if you conn...

Reviews: