background image

AirScan Hardware

User Manual

Summary of Contents for AirScan

Page 1: ...AirScan Hardware User Manual ...

Page 2: ...if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Used batteries are not to be disposed of with the house hold waste Please dispose them at your local battery collection point Instructions for disposal Do not dispose off the device as part of household garbage Electronic devices are to be disposed of in accordance with the guidelines concerning ele...

Page 3: ...e setup using the AirScan Tool It is possible to read up to 24 input points and use them for various applications within Widget Design er or Pandoras Box Measurement Principle and Restrictions The AirScan unit can be mounted above below or on the side of a screen and its recommended distance to the input screen area should not be further away then 10m or 30ft Longer distances up to 65m or 200ft ca...

Page 4: ... wall or exhibition stand make sure that the sensor to be exact the glass window is not covered and the entire interactivity area is free If a protective housing is provided for the sensor the detection must not occur through addi tional window material plastic glass etc Vapors smoke dust and all particles visible in the air could affect the measurement values Glass and highly reflective materials...

Page 5: ...168mm Measurement data transmission 100MBit s Optical data Measurement range 0 65m recommended distance 0 10m Angular range max 190 Angular resolution 0 36 Scanning rate 50 scans s or 20ms scan Wavelength 905nm Pulse Duration 3ns Electrical data Voltage supply 24VDC Overcurrent protection fuse 2 5A Current consumption approx 1A Power consumption 75W ...

Page 6: ...and not to be used M12 socket Connector3 This is the 100MBit s Ethernet socket to connect a network switch or a comput er Use the supplied Ethernet cable with the 4 pin D coded connector for the AirScan and the RJ 45 connector for the switch or computer The interface is configured with the IP address labeled on your device and the subnet mask is 255 255 255 0 Both can be changed with the AirScan I...

Page 7: ...atus indicator above connectors Left red LED 1 Ethernet system ready Middle red LED 2 Ethernet connection present Right red LED 3 Ethernet data transmission active General device status indicator on top of device Leftmost yellow LED 1 slowly 1Hz flashing internal warning message e g due to soiled sensor cover faster 4Hz flashing internal error message continuous light for internal use Green LED 2 ...

Reviews: