background image

 

RELATED DOCUMENT 

 MUST COMPLY WITH SCHEDULE DOCUMENT(S): 

CERT-iS3 MNL 

 

 

FOR A LIST OF RELEVANT PATENTS 

AND TRADEMARKS PLEASE SEE 

CHENTRONICS.COM/LEGAL-NOTICES

 

ISCAN3 MANUAL

 

PAGE 1 OF 28 

 
 

 

ISO 9001 CERTIFIED

 

DRAWN BY: 

AR 

ON: 

7/8/19 

LAST REV BY: 

 

ON: 

 

 

DCO No

 

12804

 

DWG. No.

 

 

MNL-ISCAN3

 

 

REV.

    

C

 

 

THIS 

DRAWING 

OWNED 

BY 

CHENTRONICS

IT 

IS 

CONDITIONALLY  LOANED  AND  IS  TO  BE  RETURNED  UPON 
REQUEST.  THE  BORROWER  BY  RECEIVING  IT  HAS  AGREED 
NOT  TO  REPRODUCE  NOR  COPY  IT  IN  WHOLE  OR  IN  PART 
NOR  TO  FURNISH  INFORMATION  FROM  IT  TO  OTHERS  NOR 
TO MAKE ANY USE OF IT THAT IS OR MAY BE INJURIOUS TO 

CHENTRONICS

.  FOR  MORE  INFORMATION  PLEASE  CONTACT 

CHENTRONICS

 AT +1.607.334.5531. 

TOLERANCE NOTES 

FABRICATED TOLERANCES 

 2 ft (610 mm) ± 0.250 in (6.4 mm) 

< 2ft (610 mm) ± 0.125 in (3.2 mm) 

MACHINED TOLERANCES 

± 0.050 DECIMAL DIM (1 PLACE) 

± 0.010 DECIMAL DIM (2 PLACES) 
± 0.005 DECIMAL DIM (3 PLACES)

 

MNL-ISCAN3 

 

KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE! 

Read this manual before using this product.  Failure to follow the instructions and safety precautions in this 

manual can result in serious injury or death or damage to equipment.

 

Applicable Scanner Part Numbers 

 

 

Contact Technical S1.866.821.5504 with any questions.

  

PART NUMBER 

MODEL 

AREA CLASSIFICATION 

TEMP 

RATING 

FEATURE 

CONNECTOR 

PINS 

  04004999-MB 

iS3-MB 

CLASS I/DIV II

 

-40°C to 80°C 

Fully Programmable 

 

Must Be 

Configured Prior to Use

 

 16 

  04004999-SB 

iS3-SB 

CLASS I/DIV II

 

-40°C to 80°C 

Limited Programmability

 

 16 

04005000-MB 

iS3Z-MB 

CLASS I/DIV II/ZONE 2/ATEX

 

-40°C to 80°C 

Fully Programmable 

 

Must Be 

Configured Prior to Use

 

16 

04005000-SB 

iS3Z-SB 

CLASS I/DIV II/ZONE 2/ATEX

 

-40°C to 80°C 

Limited Programmability

 

16 

Summary of Contents for IS3-MB

Page 1: ...t 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE Read this...

Page 2: ...CE NOTES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 Con...

Page 3: ...Using Equipment The instructions provided in this manual have been prepared to serve as a general guide It is intended for use by qualified personnel with knowledge of equipment of this type It is no...

Page 4: ...an explosive atmosphere may be present Equipment must be installed and serviced by qualified personnel in accordance with applicable local and national codes standards and ordinances Lisez toutes les...

Page 5: ...n 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 Indique un danger avec un niveau lev de risque qui s...

Page 6: ...US TO CHENTRONICS FOR MORE INFORMATION PLEASE CONTACT CHENTRONICS AT 1 607 334 5531 TOLERANCE NOTES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 0...

Page 7: ...ED NOT TO REPRODUCE NOR COPY IT IN WHOLE OR IN PART NOR TO FURNISH INFORMATION FROM IT TO OTHERS NOR TO MAKE ANY USE OF IT THAT IS OR MAY BE INJURIOUS TO CHENTRONICS FOR MORE INFORMATION PLEASE CONTAC...

Page 8: ...mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 The Ring of Light communicates the scanner s operating mod...

Page 9: ...NL ISCAN3 Thermal Protection The iScan3 Flame Scanner has redundant safety features for exposure above the maximum temperature rating The modes of operation are described below Mode Internal Temperatu...

Page 10: ...quency refers to the modulation of flame intensity due to micro explosions FDORT Flame Detector ON Response Time the period of time from flame intensity rising above the user adjustable threshold to f...

Page 11: ...CE NOTES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 Spe...

Page 12: ...LAME ON Configurable from 1 4 seconds in 1 second increments FDRT FLAME OFF Configurable from 1 4 seconds in 1 second increments MFRRT Configurable from 1 6 seconds in 1 second increments Safety Integ...

Page 13: ...me scanner this is typically integrated within the BMS as a pre start permissive to prevent start up if a false flame condition is detected This should not be considered a replacement for recommended...

Page 14: ...TO BE RETURNED UPON REQUEST THE BORROWER BY RECEIVING IT HAS AGREED NOT TO REPRODUCE NOR COPY IT IN WHOLE OR IN PART NOR TO FURNISH INFORMATION FROM IT TO OTHERS NOR TO MAKE ANY USE OF IT THAT IS OR...

Page 15: ...NJURIOUS TO CHENTRONICS FOR MORE INFORMATION PLEASE CONTACT CHENTRONICS AT 1 607 334 5531 TOLERANCE NOTES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANC...

Page 16: ...ROUND See section on grounding methods CONNECT ALL SHIELDS AT ONE END ONLY TO EARTH GROUND DO NOT GROUND SHIELDS AT THE LOCAL JUNCTION BOX Earth Ground Located at CONTROL PANEL ALL OTHER CONNECTIONS W...

Page 17: ...operation of the flame scanner To minimize the possibility of electrical noise interfering with the operation of the flame scanner Do not install ignition wires in the same conduit as the scanner wir...

Page 18: ...ES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 Cable Con...

Page 19: ...mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 Locking Nut Installation The equipment features a locking nut that loc...

Page 20: ...EN ENERGIZED TENSION DANGEREUSE NE PAS CONNECTER OU D BRANCHER LORSQUE NERG Communications Wiring RS 485 Communication with the iScan3 is RS 485 via a USB to RS 485 Converter PN 3425 057 01 RS 485 is...

Page 21: ...f the Com B wires together Make sure that the Com A and Com B wires are connected to the correct terminals on the converter An RS 485 repeater is required for every 30 scanners or 4000 ft 1200 m of le...

Page 22: ...AND IS TO BE RETURNED UPON REQUEST THE BORROWER BY RECEIVING IT HAS AGREED NOT TO REPRODUCE NOR COPY IT IN WHOLE OR IN PART NOR TO FURNISH INFORMATION FROM IT TO OTHERS NOR TO MAKE ANY USE OF IT THAT...

Page 23: ...D AND IS TO BE RETURNED UPON REQUEST THE BORROWER BY RECEIVING IT HAS AGREED NOT TO REPRODUCE NOR COPY IT IN WHOLE OR IN PART NOR TO FURNISH INFORMATION FROM IT TO OTHERS NOR TO MAKE ANY USE OF IT THA...

Page 24: ...the configuration files resident within the scanner iScan3 has a two wire or four wire option to remotely select files File select configurations are wire fault protected meaning if any wire combinati...

Page 25: ...ES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 Sighting the Scanner EXPLOSION...

Page 26: ...AT IS OR MAY BE INJURIOUS TO CHENTRONICS FOR MORE INFORMATION PLEASE CONTACT CHENTRONICS AT 1 607 334 5531 TOLERANCE NOTES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm...

Page 27: ...250 in 6 4 mm 2ft 610 mm 0 125 in 3 2 mm MACHINED TOLERANCES 0 050 DECIMAL DIM 1 PLACE 0 010 DECIMAL DIM 2 PLACES 0 005 DECIMAL DIM 3 PLACES MNL ISCAN3 DO NOT use the scanner if the LEDs are all Yello...

Page 28: ...Y USE OF IT THAT IS OR MAY BE INJURIOUS TO CHENTRONICS FOR MORE INFORMATION PLEASE CONTACT CHENTRONICS AT 1 607 334 5531 TOLERANCE NOTES FABRICATED TOLERANCES 2 ft 610 mm 0 250 in 6 4 mm 2ft 610 mm 0...

Reviews: