background image

January 2020 Version 1.1 

 
 
 
 
 
 
 
 
 
 
 
 
 

RM138 Series 

Rackmount Chassis 

User Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

     A document provides an overview of product features, functions, architecture, and support specifications.

Summary of Contents for RM138 Series

Page 1: ...January 2020 Version 1 1 RM138 Series Rackmount Chassis User Manual A document provides an overview of product features functions architecture and support specifications...

Page 2: ...in trade This document contains information on products services and or processes in development All information provided here is subject to change without notice Contact your Chenbro representative...

Page 3: ...nts Removal and Installation 17 2 1 Top Cover Removal and Installation 18 2 2 HDD Cage Removal and Installation 20 2 3 Hot swap HDD Assembly Removal and Installation 22 2 4 Internal 2 5 HDD SSD Remova...

Page 4: ...l 21 Figure 19 RM13810 HDD cage installation 21 Figure 20 3 5 hot swap HDD assembly removal 22 Figure 21 3 5 hot swap HDD assembly installation 22 Figure 22 3 5 HDD removal tool less type 23 Figure 23...

Page 5: ...ure 50 Fan module removal 4056 37 Figure 51 Fan module disassembly 4056 37 Figure 52 Fan module assembly 4056 38 Figure 53 Fan module installation 4056 38 Figure 54 Air baffle removal 39 Figure 55 Air...

Page 6: ...4 System environmental specifications summary 15 Table 5 System packing information 16 Table 6 Product weight information 16 Table 7 Drive power LED activity LED behavior 45 Table 8 Backplane specific...

Page 7: ...735 0 x 438 5 x 43 2 mm 28 94 x 17 26 x 1 70 Drive Bay RM13804 4 x 3 5 Hot swap 2 x 2 5 Internal 1 xSlim ODD 9 5 mm RM13810 10 x 2 5 Hot swap Storage Backplane RM13804 3 5 4 port 12Gbps Mini SAS HD R...

Page 8: ...RM138 Series Product Overview 8 1 1 System Features Overview Figure 1 RM13804 overview Figure 2 RM13810 overview...

Page 9: ...3804 major components overview Figure 4 RM13810 major components overview A Front Top Cover B Rear Top Cover C Label Embossing D Rear Top Cover Latch E Optical Drive Bay F Internal 2 5 HDD Bays G Fan...

Page 10: ...eries Product Overview 10 1 2 Front Panel Figure 5 RM13804 front panel Figure 6 RM13810 front panel A Rack Handles B Storage Drive Bay C Optical Drive Bay D Info Tag E Front Control Panel F Storage Dr...

Page 11: ...ct Overview 11 1 3 Back Panel Figure 7 Back panel with redundant PSU A Redundant Power Supply Unit B NIC RJ45 D Serial Port A RJ45 E Stacked USB2 0 3 0 Ports G Intel I O Module Bay C Video Port VGA F...

Page 12: ...trol panel Figure 9 RM13310 front control panel Table 1 Front control panel Label ICON Indicator button or connector A Power Button B LAN1 LAN2 Activity LED C Power LED D HDD Activity LED E System Ala...

Page 13: ...RM138 Series Product Overview 13 1 5 Chassis Dimensions Figure 10 Chassis dimensions Figure 11 Label embossing dimensions...

Page 14: ...of a given rail kit or misalignment of the server in the rack may result in failure of the rack rails causing damage to the system or personal injury Two persons to operate or the use of a mechanical...

Page 15: ...2 RVI Operating HDD class Class 1 Highest performance reliability and data integrity Class 2 A second tier of performance reliability and data integrity HDD I O throughput degradation SPEC Pass Fail C...

Page 16: ...shipment Table 5 System packaging information Part Number Single Bulk Form Factor mm Support Level 387 13804 3102A0 Single 920 x 595 x 180 L5 NOTE The design of the inner packaging components does no...

Page 17: ...variety of different storage options Up to 4 x 3 5 hot swap SAS SATA HDD RM13804 Up to 10 x 2 5 hot swap SAS SATA HDD or SSD RM13810 2 x 2 5 internal HDD or SSD up to 9 5 mm thickness RM13804 Support...

Page 18: ...top cover removal 1 Loosen two screws as shown 2 Press two buttons together while sliding the rear top cover toward the back of chassis base as the arrow indicating Figure 13 Front top cover removal...

Page 19: ...e pins for both sides NOTE Ensure that arrows on the cover indicating the back of the chassis 2 Secure it with two screws as shown Figure 15 Rear top cover installation 1 Align the guide pins of the r...

Page 20: ...o screws of the chassis base as shown 2 Pull the HDD cage toward the front panel until it unlocks 3 Remove the HDD cage vertically Figure 17 RM13804 HDD cage installation 1 Align the guide pins on the...

Page 21: ...ge toward the front panel until it unlocks 3 Remove the HDD cage vertically Figure 19 RM13810 HDD cage installation 1 Align the guide pins on the chassis base with the grooves on HDD cage and push the...

Page 22: ...hot swap HDD assembly removal 1 Press the tray button to release the lever asshown 2 Carefully pull the HDD assembly out of the drive bay Figure 21 3 5 hot swap HDD assembly installation 1 With the l...

Page 23: ...dropping unexpectedly 3 Lift the narrower side with your other fingers and release theHDD Figure 23 3 5 HDD installation tool less type 1 Slide in the HDD until align the anchor point of HDD tray 2 P...

Page 24: ...allation 24 Figure 24 3 5 HDD removal screw type 1 Loosen four screws as shown 2 Take out the HDD from the tray Figure 25 3 5 HDD installation screw type 1 Align the HDD with the anchor point on the t...

Page 25: ...e screws as shown 2 Remove the HDD SSD Figure 27 2 5 HDD SSD installation in 3 5 tray screw type 1 Align the front of the HDD SSD with the anchor point on the tray 2 Secure the 2 5 HDD SSD by three sc...

Page 26: ...val 1 Press the tray button to release the lever 2 Pull the HDD SSD assembly out of the drive bay Figure 29 2 5 hot swap HDD SSD assembly installation 1 With the lever open insert the HDD SSD assembly...

Page 27: ...tray asshown 2 Press your two thumbs on the HDD as shown NOTE Please operate this on a stable surface in case the HDD dropping unexpectedly 3 Lift the side with a concave slot by your other fingers an...

Page 28: ...2 5 HDD SSD removal screw type 1 Loosen four screws as shown 2 Take out the HDD SSD from the tray Figure 33 2 5 HDD SSD installation screw type 1 Align the front of HDD SSD with the anchor points on t...

Page 29: ...move it from the HDD SSD cage 3 Detach the plastic bracket from the HDD SSD Figure 35 RM13804 internal 2 5 HDD SSD installation 1 Attach the plastic bracket with a HDD SSD by engaging four pins with t...

Page 30: ...nstallation Figure 36 RM13804 slim ODD removal 1 Lift the side of ODD to release it 2 Take out the ODD from the cage Figure 37 RM13804 slim ODD installation 1 Align two dimples on the ODD with two hoo...

Page 31: ...em from the rack screw type 1 Loosen the two thumb screws anticlockwise 2 Firmly grab the rack handles on both sides and pull it out of the rack Figure 39 Installation of whole system into the rack sc...

Page 32: ...s on both sides as shown 2 Loosen the screws in the latches and firmly grab the rack handles on bothsides 3 Pull it out of the rack Figure 41 Installation of whole system into the rack latch type 1 Pu...

Page 33: ...Fan module removal 4028 1 Detach the mounts on the fan module from the grooves of the chassis base 2 Loosen four screws as shown to release the fan bracket from the chassisbase Figure 43 Fan module d...

Page 34: ...fan as shown and secure it with two screws 2 Insert four fan mounts as shown Figure 45 Fan module installation 4028 1 Attach the fan bracket with the chassis base and secure it with four screws 2 Ins...

Page 35: ...module with the grooves of the chassis base 2 Loosen four screws as shown to release the fan bracket from the chassisbase Figure 47 Fan module disassembly 4048 1 Detach four fan mounts from the fan mo...

Page 36: ...it with two screws 2 Attach the plastic extension holder with the fan 3 Insert four mounts as shown Figure 49 Fan module installation 4048 1 Attach the fan bracket with the chassis bottom and secure...

Page 37: ...al 4056 1 Detach the mounts on the fan module with the grooves of the chassis base 2 Loosen four screws as shown to release the fan bracket from the chassisbase Figure 51 Fan module disassembly 4056 1...

Page 38: ...as shown and secure it with two screws 2 Insert four mounts as shown Figure 53 Fan module installation 4056 1 Attach the fan bracket with the chassis base as shown and secure it with four screws 2 In...

Page 39: ...onents Removal and Installation 39 Figure 54 Air baffle removal 1 Remove the air baffle vertically from the fan guard Figure 55 Air baffle installation 1 Insert the air baffle into the fan guard until...

Page 40: ...Remove the PCIe blank Figure 57 Cards and brackets installation 2 Secure the riser card with PCIe bracket by two screws 3 Align two screw holes of PCIe slot bracket with the PCIe card and secure them...

Page 41: ...Removal and Installation 41 2 9 PSU Installation and Removal Figure 58 CRPS module installation 1 1 Remove dummy covers Figure 59 CRPS module installation 2 1 Insert the CRPS module into the PSU cage...

Page 42: ...RM138 Series System Components Removal and Installation 42 Figure 60 CRPS module removal 1 Press and hold the latch as shown 2 Pull the module handle to remove it from the cage...

Page 43: ...on Figure 61 Slide rail installation 1 84H314610 003 1 Attach the inner rail to the chassis base while aligning T pins on the side of the system with the slots on the innerrail Figure 62 Slide rail in...

Page 44: ...s Removal and Installation 44 Figure 63 Slide rail installation 3 84H314610 003 3 Lift the latch as shown 4 Secure the inner rail with one screw Figure 64 Slide rail installation 4 84H314610 003 5 Ins...

Page 45: ...The drive activity LED is driven by signals from the drive itself Drive vendors may choose to operate the activity LED different from what is described in the table above Should the activity LED on a...

Page 46: ...able SAS SATA backplanes include the following common features 12Gbps SAS and 6Gbps SAS SATA SFF 8680 12Gbps rated drive interface connectors providing both power and I O signals to attacheddevices Ho...

Page 47: ...icates storage device status Power LED Off Fault Blue on Present Access LED Green on Access Red on Failure Red 1Hz blink Rebuild Red 4Hz blink Locate Environment Monitor Temperature sensor TMP75 detec...

Page 48: ...lane Power is routed to the backplane via a power cable harness from the power supply B Mini SAS HD The backplane includes one multi port Mini SAS HD cable connector providing data signals for ten SAS...

Page 49: ...e status Power LED Off Fault Blue on Present Activity LED Green on Access Red on Failure Red 1Hz blink Rebuild Red 4Hz blink Locate Environment Monitor Temperature sensor TMP75 detection U3 Connector...

Page 50: ...ane Power is routed to the backplane via a power cable harness from the power supply B Mini SAS HD The backplane includes three multi port Mini SAS HD cable connectors providing data signals for ten S...

Page 51: ...xamine the DOA products If the damage of DOA products is caused by improper action as described above the customer will be liable for paying the related charge having occurred or paying the fee of the...

Reviews: