Smart-1 Installing and Removing 
Memory 

707305   

Protected 

2017 

This document is for Smart-1 205, 210, 225, 3050 and 3150 models. 

 

Important

 - We recommend that only experienced personnel install or 

remove hardware components. Installing or removing components 
incorrectly can permanently damage the Security Management 
Appliance.   

 

Preparing the Security Management 
Appliance 

Before you start to install or remove DIMMs, make sure that: 

 

You can connect to the WebUI or CLI to shut down the Security Management 
Appliance. 

 

The Security Management Appliance is in a clean environment and on a 
level surface. 

 

You can physically access and open the cover of the Security Management 
Appliance. 

 

You have the Check Point DIMM upgrade kit. 

Summary of Contents for Smart-1 series

Page 1: ...150 models Important We recommend that only experienced personnel install or remove hardware components Installing or removing components incorrectly can permanently damage the Security Management Appliance Preparing the Security Management Appliance Before you start to install or remove DIMMs make sure that You can connect to the WebUI or CLI to shut down the Security Management Appliance The Sec...

Page 2: ...is included in the upgrade kit The grounding plug on the rear of the Security Management Appliance provides a chassis grounding point Upgrade Kit Contents Installation guide Smart 1 Installing and Removing Memory Expansion DIMMs Upgrade kit sticker ESD grounding strap anti static Screwdriver To prepare the Security Management Appliance 1 From the WebUI or the CLI shut down the Security Management ...

Page 3: ...1 3150 cover The Smart 1 205 Smart 1 210 Smart 1 225 and Smart 1 3050 covers are similar Item Description 1 Security Management Appliance cover 2 Security Management Appliance cover screws 3 ESD grounding point location changes according to model ...

Page 4: ...nce rear panel 2 Sockets for DIMMs 3 Security Management Appliance front panel The Smart 1 205 Security Management Appliance has a default memory configuration of 4GB 2x2GB with two DIMMs The Smart 1 210 Security Management Appliance has a default memory configuration of 8GB 2x4GB with two DIMMs ...

Page 5: ... 1 210 16GB 2x8GB Remove the two 4GB DIMMs and install two 8GB DIMMs in the same slots 1 and 3 Default Upgraded Item Description Top View front of the Security Management Appliance is at the top of the diagram Top View front of the Security Management Appliance is at the top of the diagram Memory socket with DIMM installed Expansion memory socket ...

Page 6: ...6 Smart 1 225 DIMM Configuration Item Description 1 Security Management Appliance rear panel 2 Sockets for DIMMs 3 Security Management Appliance front panel ...

Page 7: ...Slots 32GB 4x8GB Install an additional two 8GB DIMMs All Default Upgraded Item Description Top View front of the Security Management Appliance is at the bottom of the diagram Top View front of the Security Management Applianceis at the bottom of the diagram Memory socket with DIMM installed Expansion memory socket ...

Page 8: ...and Smart 1 3150 DIMM Configuration Smart 1 3050 with open cover Smart 1 3150 with open cover Item Description 1 Security Management Appliance rear panel 2 Sockets for DIMMs 3 Security Management Appliance front panel ...

Page 9: ... sixteen 8GB DIMMs See diagram All 256GB 16x16GB Replace all DIMMs with sixteen 16GB DIMMs Gaia only not supported on SecurePlatform All Smart 1 3150 The Security Management Appliance has a default memory configuration of 64GB 8x8GB with eight DIMMs To upgrade to Use DIMMs Procedure Slots 128GB 16x8GB Install an additional eight 8GB DIMMs All 256GB 16x16GB Replace all DIMMs with sixteen 16GB DIMMs...

Page 10: ...ement Appliance is at the bottom of the diagram Upgraded Configuration for Smart 1 3050 64GB 128GB 256GB and Smart 1 3150 128GB 256GB Top View front of the Security Management Appliance is at the bottom of the diagram Item Description Memory socket with DIMM installed Expansion memory socket ...

Page 11: ...11 Removing the RAID Card on Smart 1 3050 The RAID Card on the Smart 1 3050 can interfere with the insertion of DIMMs To make room manually remove the card To manually remove the RAID Card ...

Page 12: ... 5 Carefully pull the RAID card out of the PCI connector Note Do not remove the SAS cable from the card Removing DIMMs Make sure that you prepare the Security Management Appliance before you remove DIMMs For more information see Preparing the Security Management Appliance To remove DIMMs from the Security Management Appliance 1 Put on the ESD strap and attach the other end to a grounding point 2 P...

Page 13: ...ement Appliance cover without tightening the appliance cover screws b Connect the power cords to the Security Management Appliance c Turn on the Security Management Appliance d Make sure that the LCD screen shows the Security Management Appliance model 5 Tighten the Security Management Appliance cover screws to secure the cover on the Security Management Appliance Installing DIMMs You can add more...

Page 14: ... 1 205 2 Smart 1 210 2 Smart 1 225 2 Smart 1 3050 8 Smart 1 3150 8 2 Press on the two white retaining clips outward 3 Align the new DIMM above the socket The top of the DIMM is smooth The bottom edge has two different length sets of contacts which connect to the slots on the socket Important Only touch the top corners of the DIMM Pressing on the heat sink or other DIMM components can damage the ha...

Page 15: ...ement Appliance 7 Make sure the DIMM s are installed correctly Important If you removed the RAID Card replace it and secure the card with its retention screw 8 Replace the Security Management Appliance cover without using the Security Management Appliance cover screws 9 Connect the power cords to the Security Management Appliance 10 Turn on the Security Management Appliance 11 Make sure that the L...

Page 16: ...hat the memory configuration is correct 1 In the CLI enter Expert mode 2 Run free g o Example for Smart 1 225 with 16GB of memory Expert gw 419463 0 free g o total used free shared buffers cached Mem 15 0 15 0 0 0 Swap 16 0 16 Note The amount of installed memory is shown in the row named Mem under the column named total For reasons related to available memory address space the total installed memo...