background image

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

User Manual 

LASER LIGHT 

AVOID DIRECT EYE EXPOSURE 

CLASS 3R LASER PRODUCT 

CLASSIFIED PER EN/IEC 60825-1:2007

Complies with FDA performance standards 

for laser products except for deviations 

pursuant to Laser Notice No. 50, dated  

June 24, 2007

 

Summary of Contents for Laser Level

Page 1: ...LIGHT AVOID DIRECT EYE EXPOSURE CLASS 3R LASER PRODUCT CLASSIFIED PER EN IEC 60825 1 2007 Complies with FDA performance standards for laser products except for deviations pursuant to Laser Notice No 50 dated June 24 2007 ...

Page 2: ...TE IR 12 Auto Programs 12 5 APPENDIX 13 GENERAL TROUBLESHOOTING 13 GENERAL MAINTENANCE 14 RETURNS PROCEDURE 15 TECHNICAL SPECIFICATIONS 16 CONTACT US 16 Contact Information World Headquarters United Kingdom Ireland CHAUVET CHAUVET Europe Ltd General Information Address 5200 NW 108th Avenue Sunrise FL 33351 Voice 954 929 1115 Fax 954 929 5560 Toll free 800 762 1084 Technical Support Voice 954 929 1...

Page 3: ...in seven 7 days of receiving the merchandise Manual Conventions CHAUVET manuals use the following conventions to differentiate certain types of information from the regular text Convention Meaning Menu A key to be pressed on the product s control panel 1 512 A range of values 50 60 A set of values of which only one can be chosen Settings A menu option not to be modified for example showing the ope...

Page 4: ...ct the nearest authorized technical assistance center Never connect this product to a dimmer pack Make sure the power cord is not crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Never carry a product from the power cord or any moving part Always use the hanging mounting bracket or the handles Always avoid direct eye exposure to the light source when this produc...

Page 5: ... people can get exposed This is true even if it is aimed below people s faces such as on a dance floor Do not operate the laser without first reading and understanding all safety and technical data in this manual Always set up and install all laser effects so that all laser light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Usage section later in this manual A...

Page 6: ...MinLaser User Manual 6 August 2011 Laser Safety Label Reproduction Front Rear Top Bottom ...

Page 7: ...ata Laser Classification Class 3R Green Laser Medium DPSS Nd YVO4 532 nm Red Laser Medium LD GaAIAs 650 nm Beam Diameter 5mm at aperture Pulse Data All pulses 4 Hz 0 25 sec Divergence each beam 2 mrad Divergence total light 160 degrees Laser Power of Each Beam from Aperture 5 mW As measured under IEC measurement conditions for classification Laser Compliance Statement This laser product complies w...

Page 8: ...MinLaser User Manual 8 August 2011 2 INTRODUCTION Product Overview Laser Output Mode Button Microphone LED Indicator Wireless Remote Receiver Cooling Fan Green Laser Dimmer 12 V Power In ...

Page 9: ...a 0 to 100 switch Always connect the fixture to a circuit with a suitable electrical ground Mounting Orientation The MiN Laser FX RGX STAR may be mounted in any position provided there is adequate room for ventilation Rigging Be sure that the structure can support the weight of the fixture Please see the Technical Specifications section of this manual for a detailed weight listing Mount the fixtur...

Page 10: ...MinLaser User Manual 10 August 2011 Angle Adjustment Knob A Adjustable Stand Angle Adjustment Knob B Floor Stand Flexible Feet 3 ...

Page 11: ...ting hardware from your lighting vendor International laser safety regulations require that laser products must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 3 meters of horizontal separation is required between laser light and audience or other public spaces CAUTION USE OF ...

Page 12: ...c mode is selected Wireless Remote IR Auto Programs Auto Program Description 1 Static Effect red green on 2 Slow rotation red green on 3 Slow rotation red green strobing 4 Medium rotation red green on 5 Medium rotation red green strobing 6 Fast rotation red green on 7 Fast rotation red green strobing 8 Programmed rotation red green on 9 Programmed rotation red green strobing The wireless Remote IR...

Page 13: ...sing Damaged DMX cables Check DMX cables Wrong polarity settings on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Replace DMX input Faulty Main PCB Replace Main PCB Loss of signal Non DMX cables Use only DMX compatible cables Bouncing signals Install terminator as suggested Long cable Low level signal Install amplifier...

Page 14: ...n the fixture is cool with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint The cleaning of external optical lenses and or mirrors must be carried out periodically to optimize light output ...

Page 15: ...provide the model number serial number and a brief description of the cause for the return Be sure to pack fixture properly any shipping damage resulting from inadequate packaging is the customer s responsibility As a suggestion proper UPS packing or double boxing is always a safe method to use CHAUVET reserves the right to use its own discretion to repair or replace product s If you are given an ...

Page 16: ...r use only THERMAL Maximum ambient temperature 104 F 40 C CONTROL PROGRAMMING Data input wireless remote included ORDERING INFORMATION MiN Laser FX MINLASERFX MiN Laser RGX MINLASERRGX MiN Laser STAR MINLASERSTAR Wireless Remote MiN Laser IR WARRANTY INFORMATION Warranty fixture excluding the laser diodes 1 year limited warranty Warranty laser diodes 90 day limited warranty CONTACT US WORLD WIDE G...