background image

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

User Manual 

Summary of Contents for GigBar LT

Page 1: ...User Manual ...

Page 2: ...ging 8 4 Operation 9 Control Panel Operation 9 Menu Map 9 DMX Linking 10 Configuration DMX 10 DMX Personality and Starting Address 10 DMX Channel Assignments and Values 10 17CH 10 17CH cont 11 06CH 12 03CH 12 Configuration Standalone 13 Auto Mixed Effects 13 Sound Active Mixed Effects 13 Show Mode 13 Color Mixing 14 Rearranging the Fixtures 14 Factory Reset 14 Master Slave Mode 14 Footswitch Opera...

Page 3: ...ion or operation information Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The product may not function correctly if this information is not used Useful information Disclaimer Chauvet believes that the information contained in this manual is accurate in all respects Howeve...

Page 4: ... that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilation s...

Page 5: ...21 2 INTRODUCTION Product Overview Power In Sound Sensitivity Knob Fuse Holder IR Sensor DMX In Out Strobe LEDs Safety Loop LED Display Menu Buttons Power Out Back Panel View Front View IR Sensor Microphone Footswitch Plug Pars Moonflowers ...

Page 6: ...Page 6 of 21 GigBAR LT User Manual Rev 1 Product Dimensions 12 9 in 330 mm 41 1 in 1 045 mm 5 3 in 135 mm ...

Page 7: ...e rheostat or dimmer channel serves only as a 0 to 100 switch Fuse Replacement 1 Wedge the tip of a flat head screwdriver into the slot of the fuse holder 2 Pry the fuse holder out of the housing 3 Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating 4 Insert the fuse holder back in place and reconnect power Disconnect the product from the power outlet be...

Page 8: ...ht See the Technical Specifications for weight information When mounting the product overhead always use a safety cable Mount the product securely to a rigging point whether an elevated platform or a truss When rigging the product onto a truss use a mounting clamp of appropriate weight capacity When power linking multiple products mount the products close enough for power linking cables to reach T...

Page 9: ...ShoW AP AP01 AP07 F 01 F 99 Auto Par programs speed AM01 F 01 F 99 Auto Moonflower programs speed AS AS01 AS10 F 01 F 99 Auto Strobe programs speed APM APM1 APM4 F 01 F 99 Auto Par Moonflower programs speed APS1 F 01 F 99 Auto Par Strobe programs speed AMS1 F 01 F 99 Auto Moonflower Strobe programs speed SP SP01 SP07 Sound Active par programs SM01 Sound Active Moonflower program SS SS01 SS10 Sound...

Page 10: ...iar with the DMX protocol download the DMX Primer from www chauvetlighting com To select the starting address do the following 1 Press MENU repeatedly until d_ _ _ shows on the display 2 Press ENTER 3 Use UP or DOWN to select 17CH 06CH or 03CH 4 Press ENTER and d 1 d496 for 17CH d 1 d507 for 06CH or d 1 d510 for 03CH will show on the display 5 Use UP or DOWN to select the starting address 6 Press ...

Page 11: ...00ó224 Auto single color loop 225ó255 Auto two color loop 13 Moonflower 2 Strobe When CH12 is 025ó199 000ó009 No function 010ó239 Strobe slow to fast 240ó255 Sound activated strobe Moonflower 2 Auto Speed When CH12 is 200ó255 000ó239 Auto speed slow to fast 240ó255 Sound activated mode 14 Moonflower 2 Rotation 000ó004 Stop 005ó127 Rotate clockwise slow to fast 128ó133 Stop 134ó255 Rotate counter c...

Page 12: ...Percent Setting 1 Auto Sound Programs 000ó009 No function 010ó119 Auto mixed effect 1 slow to fast 120ó229 Auto mixed effect 2 slow to fast 230ó234 Sound activated mixed effect 1 235ó239 Sound activated mixed effect 2 240ó255 Show mode CH2 must be active 2 Show Mode CH1 must be 240ó255 000ó009 No function 010ó029 Pars 030ó049 Moonflowers 050ó069 Strobes 070ó089 Pars Moonflowers 090ó109 Pars Strobe...

Page 13: ...nd Sensitivity Knob up until the product responds to the beat of the music See the Product Overview for more information The product will only respond to low frequencies of music bass and drums Show Mode To run the product in Show Mode follow the instructions below 1 Press MENU repeatedly until ShoW shows on the display 2 Press ENTER 3 Use UP or DOWN to select AP Auto Pars AM01 Auto Moonflowers AS...

Page 14: ...R Factory Reset To reset the product to factory defaults do the following 1 Press MENU repeatedly until SYS shows on the display 2 Press ENTER 3 Use UP or DOWN to select rSEt 4 Press ENTER Master Slave Mode The Master Slave mode allows a single GigBAR LT product the master to control the actions of one or more GigBAR LT products the slaves without the need of a DMX controller The master product wi...

Page 15: ... par and moonflower effect 2 8th press Show Auto par and moonflower effect 3 9th press Show Auto par and strobe effect 10th press Show Auto moonflower and strobe effect 2 Sound 1st press Sud1 Sound active mixed effect 1 2nd press Sud2 Sound active mixed effect 2 3rd press Show Sound active par effect 1 4th press Show Sound active par effect 2 5th press Show Sound active moonflower effect 6th press...

Page 16: ...AR LT IRC 6 Buttons Auto Mode Sound Active Mode Strobe Modes 0 Mixed effect 1 default 0 Strobe all default 1 Mixed effect 2 1 Strobe Auto 1 2 Par 1 2 Strobe Auto 2 3 Par 2 3 Strobe Auto 3 4 Moonflower 4 Strobe Auto 4 5 Par Moonflower 1 5 Strobe Auto 5 6 Par Moonflower 2 6 Strobe Auto 6 7 Par Moonflower 3 7 Strobe Auto 7 8 Par Strobe 8 Strobe Auto 8 9 Moonflower Strobe 9 Strobe Auto 9 Fade Mode To ...

Page 17: ...o clean the product follow the instructions below 1 Unplug the product from power 2 Wait until the product is at room temperature 3 Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents 4 Clean all transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol 5 Apply the solution directly to a soft lint free cott...

Page 18: ...100 to 240 VAC 50 60 Hz Auto ranging Parameter 120 V 60 Hz 230 V 50 Hz Consumption 47 W 43 W Operating Current 0 7 A 0 4 A Power linking current products 8 A 11 products 8 A 20 products Fuse F 1 6 A 250 V F 1 6 A 250 V Power I O U S Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison U S Local plug Light Source Pars Type Power Lifespan LED 2 6...

Page 19: ...ers 0 to 8 2 Hz Strobe Rate Strobes 0 to 13 2 Hz Beam Angle Pars 13 Field Angle Pars 27 Illuminance 2 m Pars 1 609 lux per pod Thermal Maximum External Temp Cooling System 104 F 40 C Convection DMX I O Connectors Channel Range 3 pin XLR 3 6 or 17 Ordering Product Name Item Code UPC Number GigBAR LT 10031089 781462214388 ...

Page 20: ...cal Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will re...

Page 21: ...eu World Wide Web www chauvetlighting eu General Information Chauvet Europe Ltd Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 Technical Support Email uktech chauvetlighting com World Wide Web www chauvetlighting co uk MEXICO General Information Chauvet Mexico Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C...

Reviews: