background image

Equipment Issue 1

First Printing, May 2009

Section CMPH-75CC-801

 CMPH

t

 CROSS-CONNECT SERIES INSTALLATION GUIDE 

E

Copyright 2009 Charles Industries, Inc. All rights reserved. Printed in the United States of America. 

Charles

r

 is a registered trademark of and CMPH

t

 is a trademark of Charles Industries, Ltd. Availability of features and technical specifications herein subject to change without notice.

Page 1 of 3

Figure 1.  Typical CMPH Enclosure, Dome On and Dome Off Views

Flap Latch

secured via cup-washer

screw (see Steps 5 and 6)

Ground

Line Indicator

Label

or

Decal

Areas

Dome On

Dome

Removed

Cross

Connect

Panel

(one on

both

sides)

- Installation Instructions -

CMPH-75XX Cross-Connect Series of

Charles Multi-Purpose Housing (CMPH

t

) Enclosures

1.

GENERAL

1.1

Document Purpose

This document provides installation instructions for the CMPH-75XX

Cross-Connect Series of Charles Multi-Purpose Housing (CMPH

t

) enclo-

sures, which provide a quick and easy way to cross-connect up to 1200 feed

and distribution wire pairs using high-density terminal blocks in a 

single,

above-ground enclosure. See Figure 1 for a typical CMPH-75XX Cross-

Connect series model, see Table 6 for ordering information on all products in

this series, and call Charles Industries (see Part 3) to request more information.

- NOTE -

Hereafter the Charles Multi-Purpose Housing will be referred to as the
CMPH" or enclosure."

1.2

Document Status

Whenever this document is updated, the reason will be stated in this para-

graph.

1.3

Product Purpose and Description

The CMPH-75XX Cross Connect Series is designed to provide quick, flex-

ible, high-density, cross connections between feeder and distribution cables.

The enclosure’s internal framework and large swing-out panels hold up to 24,

50-pair, cross-connect terminal blocks. These pre-stubbed terminal blocks,

which contain factory-wired 25-pair or 50-pair wire-bundles that are termi-

nated with 710 or MS

@

 connectors, can be installed initially, or easily added

at a later date without disruption of existing circuits. The swing-out panels

facilitate cable storage in the base prior to cable splicing and installer connec-

tions. This center-fed, cross-connect, interface system accommodates from

300 to 1200 pairs.

1.4 Exterior components.

 The CMPH enclosure offers easy installation, su-

perior structural strength, 360

_

 technician access, and generous internal

connection capacity. The green light-weight base and dome are made of a dura-
ble material which minimizes condensation and protects against corrosion,

floods, fire, weather, dirt, insects, intrusion, dents and impact. The top piece
of the CMPH is the dome, designed to overlap the base for a flood-protective
bell-jar effect. The base has an open top, corrugated ribbed walls, internal,
dual-purpose, molded-in, channel grooves (which accept most metallic stakes

as well as the vertical channels of the internal framework, see Figure 2), and
an open bottom. Easy replacement installations and easy underground cable
access is provided via this open base bottom.

1.5 Interior components. 

At the center of the cross-connect CMPH is an in-

ternal metallic framework that supports two, large, hinged, heavy-duty,

wind-latchable, side panels, both of which are factory-equipped with either

25-pair or 50-pair terminal blocks (see Table 6 for the specific type of terminal

block used). Up to 24 50-pair terminal blocks can be equipped in a single high-

density CMPH. Factory-prewired at the back of each terminal block is a

5-foot-long wire-bundle stub that is terminated with either a 710 connector or

an MS

@

 splice connector (per the specific model ordered). New or existing 

pre-

connectorized 

feed and distribution cables (wire gauge size of 22-26 AWG),

which also are terminated with either 710 or MS

@

 connectors, enter the bottom

of the CMPH from a trench or vault and are mated with the connectors at the

end of the terminal blocks’ wire-bundle stubs. After the cable connections are

made inside the CMPH base (lower connections), the installer performs all

wire jumper connections (upper connections). Wire race-ways are provided

for protection of all cable and jumper pairs as they are installed. The hinged,

side-access style, terminal block panels enable the installer to create very

short, easily traceable, jumper runs. The installer routes and connects jumpers

between the proper toggle of the correct terminal block in one door panel (feed-

er side) and the proper toggle of the correct terminal block in the other door

panel (distribution side).

For models equipped with MS

@

 splice connectors, the MS

@

 connector has a

two part block which contains U-contacts, wire channels, and cut-off blades.

The body of the MS

@

 splice cover module assembly and base are crimped to-

gether to terminate Feeder or Distribution pairs. Binder groups may be

identified on the module mouth and pairs can be identified on tagging cable

labels.

Also included with each CMPH is a test kit, a jumper wire spool holder, pair

identification labels, wire race-ways, splice bars, a ground bar, and other ac-

cessories (see Table 6).

1.6

Product Mounting Type and Location

The CMPH is an above-grade enclosure, the base of which is typically

installed in a trench or hole in the ground up to the base’s ground line indica-

tor, either in new or rehab-type installations around existing cables. The base

also can be mounted directly to a concrete pad using a special bracket, as well

as stake mounted. Molded channel grooves, located at the center of each inte-

rior side wall, enable stake mounting using 30”, 36” or 42” stakes. These

grooves accept most new and existing enclosures’ mounting stakes. The

ribbed or corrugated base walls provide excellent stability in most soil types.

The dome mounts on the base and protects all equipment installed or mounted

inside the CMPH.

1.7

Features

D

Side-access terminal blocks on swing-out panels facilitate cable storage

before splicing and provide greater room for spliced connections

D

Weather-resistant, gel-filled, Tyco Dat@ Term terminal blocks provide

application flexibility, rapid, pair-at-a-time, toolless, no-strip wire con-

nections

D

50-pair terminal blocks equipped with 5’ stubs which are terminated

with 3M MS

@

 splice terminals

D

Plastic base provides ease of cabinet installation over existing cables

and facilitates cabinet rehabilitation

D

Single cabinet mounting footprint for 300-1200 wire pairs

D

Durable, light-weight, plastic, impact-resistant material  provides long

life

D

Base with overlapping dome provides flood proof “bell jar” effect, to

minimize condensation and provide outstanding weather protection

D

Designed to meet Telcordia specification GR-3115-CORE

2. INSTALLATION

See Table 1 to perform a new CMPH enclosure installation. Table 2 describes

a new CMPH installation with stakes, and Table 3 describes an installation to

replace an existing enclosure (rehabilitation installation). Table 4 describes

how to make installer connections to the terminal blocks on the hinged interior

panels.

- CABLE DAMAGE WARNINGS -

Be careful not to damage any buried cables or service wires while digging either

to expose cables or to prepare a hole or trench, or while driving stakes.

- NOTE -

Never grasp or use the flap-latches as handles to lift the dome off the base; latch

breakage and possible enclosure intrusion could result.

Ground

Plate

Figure 2.  Typical CMPH Enclosure, Dome Removed, Panels Open

Dome

Cup-washer screw

(attached to base via

lanyard, see Step 7)

Hasp

(see Step 23)

Base

collar

Base

Inside

frame-

work

Locking Pins

Feeder Side Hinged panel

Distribution Side

Hinged panel

Up to 12, 50-pair,

terminal blocks

can be installed

on each door

- GROUNDING WARNINGS -

Always follow local codes and company practices for performing proper cable

and site bonding and grounding, and perform all bonding and grounding prior

to other electrical and communications connections.

Table 1.   Installing a New CMPH Enclosure

Step

 #

Instruction

 1.  

h

Obtain tools, materials and equipment.

 Gather the following

equipment to perform the CMPH installation.

h

216 tool or can wrench

h

Trenching and digging equipment and tools

h

Charles CMPH model

h

Cable grounding materials and tools

h

Scissors

knife or snips

h

Cable opening and management equipment

h

Level

h

Clean, dry, pea gravel

 (3/8"-5/8" diameter)

h

Measuring tape

h

Conduit and conduit caps

 (optional)

h

Soil tamping tool(s) 

h

Wrenches or socket set

h

Soil for backfill

h

Insulated work gloves

 (optional, to handle metallic

 

stakes)

h

Site cleanup tools

 2.  

h

Prepare trench.

 

Do not damage any buried cables or wires while

digging. 

Dig and prepare the cable trench, per company practice.

 3.  

h

Place cables (or conduit or innerduct) in trench. 

Follow company

practice to lay, place, and cut any cables and innerduct or conduit.

 4.  

h

Unpack and inspect equipment.

 Without damaging the CMPH

exterior, remove the CMPH from its packaging. Inspect the unit upon

delivery; if damaged in transit, report the damage to the shipping

company.

 5.  

h

Unlock the CMPH.

 Unlock

the CMPH using a 216 tool or

can wrench at the two cup-

washer screws (one at each

side of the CMPH); turn the

cup-washer screws counter-

clockwise until they freely

hang from their lanyard.

When locked, the cup-washer

screws prevent movement 

of the flap-latches.

Flap Latch

Cup-washer

screw

216 Tool

Lanyard

 6.  

h

Disengage the flap-latches.

 Each limited-flexibility

flap-latch contains a hole in it which accepts the

round standoff protruding from the side of the base

collar. Each latch must be pulled out or away from

base side wall just enough to clear the length 

of the protruding standoff. Maintain the 

flexed or pulled-out latch position by 

temporarily inserting the cup-washer 

screw or an item of similar diameter or 

thickness under each latch (between 

the latch and the side wall). Do not 

pry or flex the latches too far, only

enough to clear the standoff. 

Never 

grasp or use the flap-latches as 

handles to lift the dome off the base; latch

breakage and possible enclosure intrusion

could result.

Standoff

Cup-washer screw

Latch

Pull latch out. Insert

cup-washer screw

under latch.

 7.  

h

Remove the dome.

While the flap-latches

are properly disen-

gaged from the base

standoffs, grasp the

ribs at each side of

the dome and lift up

to remove the dome

from the base

The

cup-washer screws

remain attached to the

base via the lanyard (or

chain). Set aside the

dome for later use.

Standoff on Base

Cup-washer screw affixed via lanyard

Pull up on

ribs

Reviews: