Manufacturer
Chaffoteaux et Maury
(Aust.)
Appliance Name/Model
Bayard 10 CFPV
Bayard 13 CFPV
DESCRIPTION
The Bayard 10 CFPV or 13 CFPV is an open flued,
instantaneous multi-point water heater with a
gas rate of 82 MJ/h and.105 MJ/h respectively. The
unit is designed to produce an instant output of
heated water to several areas of utilization such as
baths, showers and sinks.
TECHNICAL DATA
,2 DATA PLATE LOCATION
� Adhesive label attached to the inside lower left of
� the front case .
..,
-�
>.
-�
15
·;;;
C
0
a.
0
z
'
�
C
Qj
E
t
"'
a.
QI
0
Qj
-�
2:
Qj
"'
·g
t
>
0
C
0
·.:;
GAS RA TE (MJ/h)
N.G.
T.G.
10 CFPV:
82.0
82.0
13 CFPV:
105.0 105.0
RA TED OUTPUT
(kW)
10 CFPV:
17.4
17.4
13 CFPV:
22.7
22.7
INJECTOR
ORIFICE (mm)
10 CFPV:
1.28
2.33
13 CFPV:
1.28
2.23
PILOT:
0.23
0.42
BURNER
PRESSURE (Pa)
10 CFPV:
800
280
13 CFPV:
900
460
IGNITION
T.L.P.
82.0
105.0
17.4
22.7
2.33
2.23
0.42
350
460
Piezo ignited permanent pilot.
Electrode spark gap 3mm.
L.P.(P) L.P.(B)
82.0
105.0
17.4
22.7
0.74
0.78
0.15
2750
2500
QI
::,
u..
<(I
.,,
"'
�
Qj
.s::
Chaffoteaux piezo, Part No.20267.
Chaffoteaux spark electrode, Part No.34239.
..,
� FLAME SAFEGUARD
Thermo - electric flame failure system.
Open circuit test is 15 mV minimum.
BURNER
10 CFPV Model:
12 bar, 12 injector stainless steel burner.
13 CFPV model:
14 bar, 14 injector stainless steel burner.
A.G.A. Approval No.
3460 (10CFPV)
3461 (13CFPV)
PRESSURE RELIEF
r---�-�---,
�
l "-.: ,. :, i; WQ. �JJ..i;. ' ,. ,'
:5' Ir.�,·.
t:'TI '
•
.=
• _; •• �
✓
r
.,. •
--
� • ' � •
\ � I-;:
•'· '":.,:1:...·--
Approved
N.G., T.G., T.L.P., L.P.(P)
Chaffoteaux Part No. 48987, pressure relief at
1000 kPa.
WATER
FILTER
Chaffoteaux Part No. 39803 nylon mesh filter
inserted into the waJer inlet connection.
MAXIMUM INLET WATER PRESSURE
1000 kPa.
MINIMUM INLET WATER PRESSURE
50 kPa
PERFORMANCE CHARACTERISTICS
With water flow and gas rate controls at
maximum settings;
10 CFPV, 10 litres per minute, 25
°
C temperature
rise.
13 CFPV, 13 litres per minute, 25
°
( temperature
rise.
With gas rate control at maximum setting and
water flow rate control at minimum setting;
10 CFPV, 5 litres per minute, 50
°
( temperature
rise.
13 CFPV, 6.5 litres per minute, 50
°
( temperature
rise.