024-001-909 Rev A 10-17 ConceptAir (Filters and Pre-filters)

ENG

 

USER INSTRUCTIONS: 

ConceptAir Particulate Filters & Pre-filters

R23P2/5 - R23P2OD/5 - R23PF/10 - R23PFOD/10

WARNING!

Applications and limitations.

Power Unit

Filter(s)

European Standard

Protects Against

Nominal 

Protection Factor *

ConceptAir

R23P2/5, R23P2OD/5

Main Filters

EN 12941

TH2PSL

Dusts and Particles (including solid and water 

based aerosols). R23P2OD/5 filter also helps to 

reduce odours

50

ConceptAir

R23PF/10, R23PFOD/10

Pre-filters

n/a

Optional pre-filter to prolong the life of main filter or 

reduce odours (R23PFOD/10)

n/a

*  

 The Nominal Protection Factor (NPF) is derived from the laboratory tests undertaken in EN 12941. For country specific protection factor guidance, 

 

please refer to EN 529.

Nuisance Odour Filters & Pre-filters

Nuisance Odour Filters 

R23POD/5

 filters offer the same level of protection and conform to the same standards as R23P/5 filters but in addition gives relief from 

nuisance level 

odours. 

Note: Theses filters should NOT be used against toxic levels of gas/vapour or where the gas/vapour level exceeds the Workplace Exposure 

Limit.

Nuisance Odour Pre-filters 

The nuisance odour pre-filter 

R23PFOD/10

 may be used with the R23P/5 or R23POD/5 filters to give relief from 

nuisance

 level odours. The nuisance 

odour pre-filter R23PFOD/10 can be used in conjunction with the R23POD/5 filter to give longer life.

Changing/Fitting Filters and Pre-filters

WARNING!

Care should be taken when handling filters. 

Do not touch the pleated filter medium.

Do not use filters after their expiry date. Filters are marked with an expiry of shelf life date, which is 3 years from date of manufacture for R23POD/5 and 

5 years for all other filters. 

Do not open sealed bag containing the filter until you are ready to use it.

The outside surfaces of the power unit should be decontaminated before removing the main filter. The power unit should be positioned so that the filters 

are facing downward, ensuring any trapped particulate material released by removing the filter does not fall into the filter port. 

Pre-Filters (R23PF/10 & R23PFOD/10)

The Pre-filter is available as an optional item which sits in front of the main filter and removes coarse particles. The pre-filter should be changed 

immediately if a drop in air flow is noticed or if the clogged filter alarm sounds. Pre-filters, in themselves, do not offer any respiratory protection and 

hence must only be used in conjunction with a main filter. Frequent changing of the pre-filter will maximise the life of the main filter.

R23PF/10

To fit the pre-filter, open the front cover of the power unit by easing open the right side. Remove any existing pre-filter. Lay the pre-filter in the inside of 

the front door, ensuring that it is central and swing the door closed on the hinge until it clicks in place. Ensure that you do not damage or dislodge the 

main filter.

R23PFOD/10

To fit the pre-filter, open the front cover of the power unit by easing open the right side. Remove any existing pre-filter. Lay the pre-filter in the inside of 

the front door, ensuring that it is central and that the vertical ribs in the inside of the door protrude though the slots in the top and bottom edges of the 

pre-filter. Swing the door closed on the hinge until it clicks in place. Ensure that you do not damage or dislodge the main filter.

Main filters (R23P2/5 & R23P2OD/5)

If after changing the pre-filter, the clogged filter alarm indicates low flow within a short period of time, the main filter should be changed as detailed 

below. 

The outside surfaces of the power unit should be decontaminated before removing the main filter. 

Open the front cover by easing open the right side. Check that the seal on the back of the new filter is not damaged and that there is no other damage 

to the filter. Discard any damaged filters. The power unit should be positioned so that the filters are facing downward, ensuring any trapped particulate 

material released by removing the filter does not fall into the filter port. Remove the old filter and discard. Fit the new filter squarely into the power unit and 

swing the door closed on the hinge until it clicks in place. 

Warning:

 Ensure that the door is fully and properly closed and the filter fitted in place before use.

Disposal

Contaminated filters and pre-filters should be disposed of in accordance with local Health & Safety Legislation. 

Storage

All equipment should be stored in a clean dry atmosphere (R.H. < 90%) within the temperature range -5*C to +55*C in their original packaging. It should 

be protected from direct sunlight and any material known to damage plastics, e.g. petrol and solvent vapours. Filters should be transported in their original 

packaging.
For additional information or to obtain a copy of the Declaration of Conformity, please visit www.centurionsafety.eu

Before using the ConceptAir powered respirator system it is essential that you read the instructions and ensure that the correct equipment has been 

selected. Always be aware of the limitations of use of the equipment and that it is appropriate to the task. In addition to these instructions also refer to 

the main instructions provided with the powered respirator and headpiece. You must always only use genuine ConceptAir filters, use of other filters 

will invalidate any CE product approvals and warrantee and may mean that an inadequate level of protection is given.

Summary of Contents for ConceptAir R23P2/5

Page 1: ...unction with a main filter Frequent changing of the pre filter will maximise the life of the main filter R23PF 10 To fit the pre filter open the front cover of the power unit by easing open the right...

Page 2: ...s avant d enlever le filtre principal L unit d alimentation doit tre plac e de telle fa on que les filtres sont face vers le bas ce qui garantit que tout mat riau particulaire pi g lib r par le retrai...

Page 3: ...die vordere Abdeckung der Leistungseinheit indem Sie die rechte Seite ffnen Einen evtl vorhandenen Vorfilter entfernen Legen Sie den Vorfilter mittig in die Vordert r und schlie en Sie die T r ber di...

Page 4: ...ntaci n aflojando la apertura en el lado derecho Retire los prefiltros existentes Coloque el prefiltro en la parte interior de la puerta frontal asegur ndose de que est centrado y cierre la puerta has...

Page 5: ...ezig Leg het voorfilter centraal in de daarvoor bestemde uitsparing en sluit het klepje totdat deze op zijn plaats klikt Zorg ervoor dat hierbij het hoofdfilter niet wordt beschadigd of losraakt R23PF...

Page 6: ...e il prefiltro esistente Collocare il prefiltro all interno della porta d ingresso assicurandosi che sia in posizione centrale e chiudere la porta sulla cerniera finch non scatta in posizione Assicura...

Page 7: ...ana filtra wst pnego wyd u y okres eksploatacji filtra g wnego R23PF 10 Aby umie ci filtr wst pny nale y otworzy przedni pokryw zasilacza odchylaj c j na prawo Wyj obecny filtr wst pny Umie ci filtr w...

Page 8: ...onsafety co uk 21 Howlett Way Thetford Norfolk IP24 1HZ England centurionsafety eu EU Type Examination by British Standards Institution PO Box 6221 Kitemark Court Davy Avenue Milton Keynes MK5 8PP UK...

Reviews: