background image

  
                      

Maintenance 

 

1.

 

Wipe the surface of the equipment with a slightly damp towel and dry 
it with a soft cloth. 

2.

 

When storing or travelling for a long time, please separate the battery 
from the equipment and put it in the original packing box of the 
equipment.  

 

Warning 

 

1.

 

Don’t immerse in water, keep away from liquid and heat source at the 

same time, and keep the motor cooling hole free of dust and sundries.  

2.

 

Do not disassemble screws without permission.  

3.

 

Shut down the equipment for half an hour for every hour of operation.  

4.

 

Unplug the charger from the battery after charging or before use, and 
do not use it during charging.  

5.

 

Use of this equipment is prohibited without consulting a doctor for 
the injured part of the body.  
 

Disclaimer 

 
Before using the equipment, please read the operating instructions carefully, then 
use this equipment correctly according to the instructions. The company will not 
assume any legal obligations for the injuries and losses caused by the improper use 
of the equipment according to the instructions. Do not use in high speed and high 

pressure or prohibit the use of equipment without the doctor’s approval in any of the 

following circumstances: 
 
Pregnancy, diabetes, neuropathy or retinal damage, pacemaker wear, recent surgery, 
epilepsy or migraine, disc herniation, lysis or spondylitis, recent joint replacement or 
intrauterine device or physical health problems, weak adults and children (need to be 
accompanied by healthy adults). These contradictions do not mean that you cannot 
use this equipment. We suggest you consult your doctor before using it with his 
permission. We are studying the impact of the equipment on specific medical 
diseases, which may lead to the above description not being comprehensive and 
detailed, but all people suffering from the above symptoms must be completed with 
the advice and accompanied by the doctors, experts or physiotherapists.  

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

User Manual 

 

Physiotherapy Apparatus 

for Myofascium 

CC - 9111 

 

 
 
 
 

 

 

 
 
 

 

 

 

 

 

 

Flat Head: 

 

Suitable for 

all parts of 

the body 

 

Air Plug Head: 

 

Applicable to 

bones of the 

whole body 

Spiral 
Head: 

 

Applicable 

to all joint 

parts of the 

body 

Forked 

Head: 

 

Applicable 

to pine 

Large Ball 

Head: 

 

Suitable for 

large muscle 

group 

Small Ball 

Head: 

 

Suitable for 

large muscle 

group 

 
 
1.

 

High frequency, high silence, high speed motor 

2.

 

Battery 

3.

 

Start and speed control button for motor 

4.

 

Battery  

5.

 

Charging jack 

6.

 

6 kinds of massage heads; 

7.

 

Electricity indicator lamp (when four green lights and one red light are 
from the left, it indicates sufficient battery. 

a.

 

Then as the usage time gets longer and longer, the four 
green lights will turn off from left to right, and finally only 
on the red light is on, indicating that the electricity is 
exhausted and needs to be charged). 

8.

 

Gear indicator light (the first blue light from the right lights up as first 
gear (pulse frequency: 4 1800 rpm), the second gear when two blue 
lights light up (pulse frequency: 2400 rpm), and the third when three 
lights light up (pulse frequency: 3200 rpm: 5 minutes) 

 
 

           

Instructions for use 

1.

 

When the battery switch 6 is turned to the “ON” position, both the battery power on 

indicator and the power supply power indicator 9 will be on, with 4 green lights and 1 red 
light representing the power consumption from strong to weak from left to right, and when 
only the red light is on, it means that the power consumption needs to be charged. 

2.

 

According to the different needs of massage parts, specific heads are selected to be inserted 
into the round hole in front of the fascia gun.  

 
 
 
 
 
 
 
 

 
 

3.

 

When the motor start button 4 is pressed, the motor will start to 
rotate; The first green light above the motor button lights up top 

represent gear “1”; Press the motor start button again, the two green 

lights illuminate to gear 2; Press the motor start button three times 

and the three green lights light up to represent gear 3”; Press the 

motor start button four times, then the motor stops rotating; Press 

the motor again to start “1” gear. 

 

The above is the basic cycle flow. 

4.

 

Turn off the battery switch after massage. 

5.

 

In order to protect equipment, the connection will automatically stop 
protection after 10 minutes of continuous operation. If it is still 
needed, please turn it on again.  

 

 

Battery Instructions 

 

1.

 

After the power is exhausted, the battery needs to be charged for 2.5-
3 hours to be fully charged, and the duration of battery life depends 
on the gear adjustment. 
When the battery is charged, the battery power indicator lamp 5 will 
light up, which means that the charging is normal. At the same time, it 
is forbidden to start the motor when charging. For your safety, the 
motor key cannot be started when charging the battery.  
 

 

Safety Instructions 

 

To reduce electric shock, fire and personal injury, this product must be used according 

to the following instructions. 

 

1.

 

Only for adults. 

2.

 

This equipment cannot directly massage the skin surface, so as not to 
cause damage to the skin. The massage part or the equipment should 
be covered with dry and clean clothes, and the equipment should be 
gently pressed and moved during use. The massage time for the same 
part should not exceed 60 seconds.  

3.

 

Under the condition of no pain, tumor and discomfort, only the soft 
tissue parts of the body can be used with high speed and pressure, and 
the head and any bone parts of the body cannot be used with high 
speed and pressure. 

4.

 

According to the massage needs of different parts, please select the 
appropriate massage head.  

5.

 

Frequent high-speed and high-pressure on the same part will cause 
bruises, accompanied by pain and discomfort, which should be 
stopped immediately.  

6.

 

Please keep your fingers and all your hair away from the telescopic rod 
of the equipment and the cooling hole of the motor on the back to 
prevent pinching.  

7.

 

Do not put any objects into the heat dissipation holes of the motor. 

8.

 

Do not overflow the equipment into the water. No water is allowed to 
enter the equipment from the heat dissipation hole of the motor.  

9.

 

Do not discard or misuse this equipment. 

10.

 

Only the charger provided by the original factory can be used for 
charging. 

11.

 

Please check the equipment and battery carefully before each use. 

12.

 

Don’t make any modifications to the equipment without permission.

 

13.

 

Do not operate the equipment and charge the equipment in 
unattended condition.  

Reviews: