background image

Summary of Contents for SL Series

Page 1: ......

Page 2: ... may not be copied reproduced translated transmitted or reduced to any printed or electronic medium or to any machine readable form for any purpose in whole or in part without the written consent of CellarCool Every effort has been made to ensure that the information in this manual is accurate CellarCool is not responsible for printing or clerical errors CellarCool reserves the right to make corre...

Page 3: ...The Unit Quick Start Guide Preparing the Wine Cellar Through the Wall Installation Pre Installation Preparing the Installation Location Installation System Operation Control Functions Maintenance Schedule Troubleshooting Guide Technical Assistance Accessories Installation Terms and Conditions 2 3 4 5 6 7 10 11 12 14 15 18 19 21 22 ...

Page 4: ...2212 Page 2 1 855 235 5271 Rear Side View out of cellar condenser QUICK REFERENCE GUIDE Front Side View in cellar evaporator Bottom View Controller Air Sensing Power Cord Power Cord Grille Grille Drain Port ...

Page 5: ... the min stored temperature In programming mode use to browse the parameter codes or decrease the displayed value 1 Energy Saving Button 1 Cellar Pre Chill Button 3 5 Push to see the max stored temperature In programming mode use to browse the parameter codes or increase the display value Hold for 3 seconds to start Cellar Pre Chill Set Button View Set Point 1 Change Set Point 3 5 SET Down CPSM 10...

Page 6: ...rder to ensure the longevity of your cooling unit the equipment should be installed properly and have a proper care and maintenance schedule Please read and review this manual carefully and keep it for future reference What Is the CellarCool SL2500 Cooling System The CellarCool SL2500 system is a specialized refrigeration unit designed for one purpose only to maintain the opti mal temperature and ...

Page 7: ...shipment Review the Packing Slip to Verify Contents Check the model number to ensure it is correct Check that all factory options ordered are listed If any items listed on the packing slip do not match your order information contact CellarCool Customer Service im mediately Check the Box for the following contents Mounting Brackets 2 Accessory Kit One CellarCool SL2500 Owner s Manual Accessory Kit ...

Page 8: ...be 10 15 F cooler than the air in the room This means that in an environment where the air is 80 F the unit will discharge air that is 65 70 F 6 It is REQUIRED to install a drain line to remove condensation from the unit 7 The CellarCool unit is intended for use in properly designed and constructed wine cellars Hire a professional wine storage consultant with a valid contractor s license to build ...

Page 9: ...llarCool product Standard fiberglass or rigid foam insulation is nor mally used in cellar construction or in some cases blown in insulation is used It is very important that all walls and ceilings are insulated to keep the cellar temperature as consistent as possible during the summer and winter months The R value or quality of insulation is determined by the rate at which heat passes through the ...

Page 10: ...jamb A bottom sweep or threshold is also required The door must have a very good seal to keep the cool cellar air from escaping out of the cellar One of the most common problems with cooling units running continually is due to the door not sealing properly Mounting the Unit The unit must be mounted within 18 of the top of the room in order to achieve sufficient cooling As the room cools down the w...

Page 11: ...of the unit However you must have a fresh air inlet as well Note If you are unsure about having adequate ventilation in your install location please contact us to assess your specific installation at support CellarCool com or 1 855 235 5271 Warning allowing your system to operate in high ambient temperatures for extended periods of time will greatly decrease the life of your system and void your w...

Page 12: ... RECOMMEND THAT YOU DO NOT USE A GROUND FAULT INTERRUPTER GFI WITH THIS PRODUCT TEST THE UNIT PRIOR TO INSTALLATION To prepare it for testing before installation in wall Remove unit from box Place unit on tabletop Plug in unit to electrical outlet Turn on to test Temperature differential should be 10 F across coils Turn off after test Testing Unit Place the CellarCool system on a tabletop to prepa...

Page 13: ...for framing and construction needs Locate the desired installation location using a level and a pencil mark a center line Mark the center line for your desired installation location followed by laying out the hole for the unit Hole size 22 1 2 inches by 10 3 4 inches Cut out the drywall and studs for the unit opening Warning Use caution not to cut through any electrical or plumbing In most cases f...

Page 14: ...ne tube is used to remove excess condensation from the unit to a proper discharge location It is important that the drain line tube is properly connected and used to prevent leakage and other problems associated with excess condensation Failure to use the condensation drain line tube will void the warranty on the unit Note To prevent mold from growing allow the drain line to hang above the water l...

Page 15: ...www cellarcool com Page 13 NOTES ...

Page 16: ...justed Anti Short Cycle The Anti Short Cycle ensures that the unit will remain off for a period of 3 minutes after the unit has reached the set point to allow the pressure in the refrigeration system to equalize prior to starting the compressor Anti Frost Cycle The Anti Frost Cycle is a precautionary measure as icing or frosting of the coil does not occur during normal operation The system will go...

Page 17: ...set at initial Start Up and after the Cellar or Cabinet has obtained normal operating temperatures which is generally 55 F Cellar PreChill CPC The CPC Feature is activated by pressing the Up button for 3 5 seconds and the CPC logo will be displayed on the digital display The CPC feature can be terminated by pressing the Up button for 3 5 seconds or the feature will self terminate after 6 hrs 1 The...

Page 18: ...uring this cycle the compressor and condenser fans will turn off and the evaporator fans will continue to run Once the temperature of the evaporator gets back up to 40 the cycle will deactivate and the system will revert back to normal operating conditions At the beginning of the cycle the symbol will be illuminated and the symbol is illuminated during the anti frost cycle Alarm The Alarm symbol i...

Page 19: ...nt This parameter is normally set at 15 This parameter should not be adjusted as it simply provides an OFF cycle time for the fan during the compressor OFF cycle However the parameter is located within the CPSM as a convenience to the customer should it need to be adjusted CCS Cellar Pre Chill Set Point This parameter is set at 52 f but can be adjusted to a set point be tween 50 f 67 f CCT Cellar ...

Page 20: ...ion 3 Check wiring connections and integrity of cords 4 Pour a 50 50 bleach solution into the drainline every spring It is the user s responsibility to remove any accumulated dust lint or other debris from the front and rear intake grilles This will restrict the airflow and may affect the unit s ability to function properly Periodically cleaning the unit s vents will help assure maximum cooling ef...

Page 21: ...o airflow obstruction Make sure there are no air gaps around the door If door seal is damaged replace it Lower the set point Observe ice formation pattern If only part way up the coil face unit could be low on refrigerant If so call Customer Service at 855 235 5271 TROUBLESHOOTING GUIDE Unit has ice forming on the evaporator Possible Cause Evaporator coil is dirty There is something blocking the s...

Page 22: ...t ing If problem repeats call customer service Solution Call Customer Service at 855 235 5271 Call Customer Service at 855 235 5271 Solution Move Air Sensing Probe to a more central location Call Customer Service at 855 235 5271 Call Customer Service at 855 235 5271 Call Customer Service at 855 235 5271 Solution Install proper vapor barrier Unit leaks water Possible Cause Unit is not level Drain l...

Page 23: ...customize your SL2500 wine cooling unit ThruWall Room to Room Fan The ThruWall Room to Room Fan balances temperatures in adjoining rooms by transfering warm air out of exhaust room quietly and efficiently Simple to install in any frame wall from 3 1 2 to 6 3 4 thick A high quality Thermally Protected motor with balanced fan blade moves up to 200 CFM Move heated or cooled air between rooms Condensa...

Page 24: ...w or rebuilt replacement parts for the Product in exchange for the return of defective parts and 3 FREIGHT cover normal ground freight charges for parts and in the event the Product is not repairable in the field cover normal ground freight charges within the continental United States for the repair or replacement of the Product B Five 5 Year Compressor Limited Warranty CellarCool Products compres...

Page 25: ...s sole discretion void this limited warranty 10 No one has any authority to add to or vary the limited warranty on this Product 3 Product Installation Requirements A Prior to installing a CellarCool Product the End User must read the CellarCool Owner s Manual and thereafter the End User must follow the required installation use and maintenance procedures set forth by CellarCool in CellarCool s Own...

Page 26: ...o 4 00 p m PST at telephone number 1 800 343 9463 CellarCool Corporation is located at 1738 East Alpine Avenue Stockton California 95205 8 Miscellaneous Terms and Conditions A Return Policy All return inquiries must be made within thirty 30 calendar days of the original purchase of a Product and are subject to a twenty five percent 25 restocking fee Shipping costs are not refundable and the Purcha...

Page 27: ...d a letter via U S Mail to Customer Service CellarCool Corporation 1738 E Alpine Ave Stockton CA 95205 Email support cellarcool com Web www cellarcool com B Technical Assistance CellarCool Customer Service is available Monday through Friday from 6 30 a m to 4 00 p m PST The Customer Service representative will be able to assist you with your questions and warranty information more effectively if y...

Page 28: ...CellarCool 1738 E Alpine Ave Stockton CA 95205 1 855 235 5271 1 855 Cellar1 www cellarcool com ...

Reviews: