background image

BUILDING ELEMENT CLEARANCES FOR RECESSED LUMINAIRES

** Minimum insulation clearance (MIC) – from insulation to building element above
** Side clearance to building element (SCB) = 0mm
** Height clearance to building element (HCB) =0mm from top of luminaire to building 
element above

Downlights can be installed in timber ceilings and  come into contact with normally flammable 
Building Material. (ie material having ignition temperature of at least 200deg ).

CAUTION:
Recessed luminaries and their auxiliary equipment may pose a risk of fire or damage to 
property if not installed and maintained correctly.

SAFETY NOTICE
If you have any doubts about your ability to conduct the wiring work safely or about the 
method of installing light fittings, please employ a licensed electrical worker to carry out the 
installation for you. Failure to wire incorrectly may result in electric shock injury or a fatality to 
yourself or a member of your family.

INSTALLATION LOCATION:

This type of IC-F recessed luminaire can be abutted and covered with thermal building 
insulation with a minimum temperature rating of 90

o

C.

LED Driver must be a minimum of 50mm away from any part of the luminaire at all times, 
as noted in the diagram below.

We recommend mounting  the LED Driver on the nearest joist, beam, rafter or ceiling 
batten above the level of the building insulation.

LED DRIVER INSTALLATION:

CAUTION:
ISOLATE (TURN OFF) MAINS SUPPLY BEFORE CONNECTING THE LED DRIVER.

1.

Locate the LED Driver in a well ventilated area, free from any insulating material and as far away 
from the downlight as possible. Failure to do so may cause the LED Driver to overheat.

2.

Do not lead the mains wiring along the side of the LED Driver.

3.

Connect the power cable from the mains (2 x), into the 220V-240V input terminals (N, Neutral, 
Blue), (L, Live, Brown) on the LED Driver. Alternatively, the driver has been supplied with pre-
wired double insulated cables for your convenience, please ensure that any connection made 
complies with New Zealand Electrical Wiring rules AS/NZS 3000.

4.

Ensure that all connections to both input and output leads are secure. 

5.

Do not swap the LED Driver for any other model, it is specific to the integrated LED downlight as 
supplied.

DLED10WD, DLED10BD
LED DOWNLIGHT
(Dimmable)
INSTALLATION INSTRUCTIONS:

NOTE: LED Driver can be placed under 
insulation, however it is not recommended 
as the driver’s lifespan will be reduced and 
the warranty made void.