manualshive.com logo in svg
background image

PSR529 series 

Quick Start Guide

Power distribution unit

The quick start guide gives you an overview of all the front and rear controls and 

connections on the PSR529 series. It allows you to get started with the installation of 

it in your project.   

Front: 

2) Power button LED light

Switches the LED light ON or OFF

4) LED indicator: 

- Power indicator: The power is ON 

when the LED is illuminated.

- Failure indicator: The LED illuminates 

when surge current is detected. If the 

LED is not illuminated, no surge current 

is detected. 

- Reverse polarity / grounding indicator: 

the LED lights up when no grounding 

is detected or when the polarity is 

reversed. 

If the LED is not illuminated, the unit is 

grounded and the polarity is correct.

1) USB charger

The two USB type A connectors offer 

the possibility to charge various devices 

such as smartphones, tablets or similar 

devices. It is not designed for plugging in 

USB memory devices.

3) LED dimmer 

The LED light can be dimmed by turning 

the dial. 

1

1

3

7

2

4

6

5

Содержание PSR529 Series

Страница 1: ...ure indicator The LED illuminates when surge current is detected If the LED is not illuminated no surge current is detected Reverse polarity grounding indicator the LED lights up when no grounding is detected or when the polarity is reversed If the LED is not illuminated the unit is grounded and the polarity is correct 1 USB charger The two USB type A connectors offer the possibility to charge var...

Страница 2: ...omatically switch over 7 Construction The construction is made using black powder coated aluminum fitted with steel 19 mounting ears on each side The total height covers a single 19 rackspace allowing it to be installed in any 19 housing or equipment rack 8 AC power lead The mains power supply 250V AC 50 60Hz is standard fitted The connection cable has a length of 2 5 meters Back 9 Power outlet Th...

Страница 3: ...urrent IR 16A Maximum power load Pmax 4000W Surge protection specifications Maximum continuous working voltage Ur 1000V Nominal discharge current 8 20µS In 10 KA Voltage protection level Up 1000 V Response time tA 25 nS Insulation resistance Ris 100 MΩ USB Port specifications 2 x USB Type A connections 5V 2 1 A supply two ports combined LED light specifications Switchable ON OFF switch Dimmable be...

Страница 4: ...hown are internationally recognized symbols that warn about potentional hazards of electrical products The lightning flash with arrowpoint in an equilateral triangle means that the unit contains dangerous voltages The exclamation point in an equilateral triangle indicates that it is necessary for the user to refer to the users manual CAUTION ALWAYS KEEP THESE INSTRUCTIONS NEVER THROW THEM AWAY ALW...

Отзывы: