PREPARATION

1.

Check to make sure all components are complete and that there is no 
concealed damage. If there is concealed damage, notify carrier 
immediately. Car-Mon will not be responsible for equipment not inspected 
on receipt from carrier.

2.

Review the instructions to make sure any materials needed for installation 
not included by Car-Mon are provided by the installer.

3.

The main components for the system include a wall or ceiling platform, a 
CMW direct drive fan, a single or dual tubing assembly with swivel or 
swivel socket, gaskets, and hardware. The optional equipment may 
include the BA Balancer, tubing sling, pull-up set, or wall 
storage brackets.

INSTALLATION

1.

Make sure the mounting surfaces where the CO-X platform 
and fan is to be mounted is level and plumb and can support 
the weight of the entire unit. Wall mounted platforms are 
installed "legs down" using the pre-drilled mounting holes. 
Ceiling platforms should be securely attached to the building 
structure using the mounting holes. Both units may also be 
welded to the attached surface.

2.

Position CMW fan on platform using a gasket between the 
fan and the platform, lining up the holes and making sure the 
fan is in the proper discharge direction. Drop the 5/16 bolts 
through the bolt holes.

3.

Attach the single or dual tube and swivel assembly to the  
bottom of the platform using a gasket between the assembly 
and the platform. Using the bolts from the fan above fasten 
with the nuts  provided. Attach the fan discharge to the 

ductwork. For attachment of the optional balancer, see the 
instructions at the end of this manual.

4.

Wire the fan motor. See the fan wiring diagrams on Page 2. 

Make sure the diagram matches the model number on the motor plate. If it 
does not, consult the wiring diagram on the motor plate, or call customer 
service at the factory.  The installation is now complete and the system can 
be tested. When testing briefly start and stop the motor to see if the rotation 
of the fan is correct. If it is not, recheck the wiring of the fan. After checking 
rotation, run system for several minutes to check for any vibration or excess 
noise, and to see if there is good air flow through the tube(s).

OPERATION

1.

Attach the exhaust adapter the vehicle tailpipe. The vehicle SHOULD NOT 

be running while the attachment is made. Make sure the fan on the system 
is running and air is going through the tubing before the vehicle is started. 
Starting a vehicle with a exhaust adapter attached and the fan not running is 
unsafe and may cause damage to the tubing drop. After servicing, shut off the vehicle, leaving the 
tubing assembly attached and the fan running. Continue to run the fan for a short time to let the 
ambient air running through the tube cool it down before detaching it. Care should always be taken 
when removing the tubing assembly as it can remain hot for a period of time if not cooled with 
ambient air.

CEILING MOUNTED

DUAL  SYSTEM

CMW DIRECT

DRIVE FAN

SWIVEL

FLANGE

CONNECTION

WALL

BRACKET

TUBE

ASSEMBLY

WALL MOUNTED

DUAL SYSTEM

WALL MOUNTED

SINGLE SYSTEM

Page 1

Summary of Contents for CO-X Series

Page 1: ...the platform using a gasket between the assembly and the platform Using the bolts from the fan above fasten with the nuts provided Attach the fan discharge to the ductwork For attachment of the optional balancer see the instructions at the end of this manual 4 Wire the fan motor See the fan wiring diagrams on Page 2 Make sure the diagram matches the model number on the motor plate If it does not c...

Page 2: ...DV 9 LEADS This diagram covers most standard C FACE ODP 1 phase Baldor motors HP THRU 1 HP supplied on Car Mon CMW flange mount fans Check model numbers below VL1303 VL1306 VL1309 VL1313 ELEC CENT SWITCH OPTIONAL T STAT 1 2 3 4 J J 5 8 VOLT HIGH HIGH LOW LOW STD OPP STD OPP LINE A 1 1 1 3 8 1 3 5 LINE B 4 5 4 8 2 4 5 2 4 8 JOIN 2 3 8 2 3 5 _ _ SINGLE PHASE TYPE L DUAL VOLTAGE REVERSIBLE 6 LEAD CAR...

Page 3: ...of balancer CAUTION As tension is reduced tool will fall away from the balancer 3 Allow the shaft to turn SLOWLY in clockwise direction until tubing is lowered to desired working height CAUTION Do NOT allow the spring to unwind in an uncontrolled manner This can result in damage to the balancer and may result in personal injury RATCHET LOCK USE 1 Engage the ratchet lock by pulling cable out to des...

Page 4: ...kmanship or materials within 1 year from date of shipment The foregoing is in lieu of all warranties expressed or implied and all other obligations or liabilities on behalf of the company regarding products it may manufacture or sell Except as otherwise provided herein the purchaser accepts the product as is No warranty is made regarding the suitability or compatibility of any Car Mon product for ...

Reviews: