background image

Powerbox Australia Pty Ltd

Powerbox Pacific Ltd

4 Beaumont Rd Mount Kuring Gai NSW 2080 AUSTRALIA

1800 251 380  [email protected]   

www.powerbox.com.au

 

1a Henry Rose Place Albany Auckland 0632 NEW ZEALAND

09 4158 320   [email protected]    

www.powerbox.co.nz

 

Sydney

 (Head Office) 

Auckland 

(Subject to alterations.  This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)

Version 1.0  10/2018

1

 

 

Camtec Power Supplies GmbH – Gewerbestrasse 30 – D-76327 Pfinztal – Germany        

p.1/8 (12.2017.02.0)

 

Phone +49(721)46596-0  -  Fax +49(721)46596-77 – 

www.camtec-gmbh.com

 - 

[email protected]

 

(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death) 

HSEUREG10001

  

1000W Programmable DC Lab Power Supply, TS35mm DIN-Rail  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Specification: 

 

Save 0–Umax programming 

 

Multi interface 0-10V & 0-20mA 

 

Sense & Shutdown (remote ON/OFF) 

 

N+1 parallel operation 

 

Natural Convection 

 

Precise dynamic response on load change 
 

 

 

Designed for long life under full stress 

 

Strong input filters 

 

High reliability, shock & vibration proof  

 

EMC meets CE norm class B 

 

Over Voltage and continuous short circuit protection  

 

Double terminals 4x AWG20 – AWG6 (0,5 – 16mm²) 
 

 

 

Models 

Programmable Voltage 

HSEUREG10001.015T 

0-15Vdc / 50A 

HSEUREG10001.030T 

0-30Vdc / 33A 

HSEUREG10001.050T 

0-50Vdc / 20A 

HSEUREG10001.090T 

0-90Vdc / 11.2A 

HSEUREG10001.130T 

0-130Vdc / 7.8A 

HSEUREG10001.180T 

0-180Vdc / 5.6A 

 

 

 

 

 

 

Summary of Contents for HSEUREG10001 Series

Page 1: ... Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death HSEUREG10001 1000W Programmable DC Lab Power Supply TS35mm DIN Rail Specification Save 0 Umax programming Multi interface 0 10V 0 20mA Sense Shutdown remote ON OFF N 1 parallel operation Natural Convection Precise dynamic resp...

Page 2: ... interface are electrically isolated The design specifications call for the highest standards of safety and interference suppression The device was developed in accordance with the requirements of IEC CSA UL60950 1 and the EMC standards EN55022 Class B The 480W and 720W models provide natural convection The 1kW models use a forced air cooling system with a two stages fan In selecting the fan as wi...

Page 3: ...z 50mVpp 50mVpp 100mVpp 200mVpp 250mVpp 300mVpp Sense function Compensation 2V per lead load protective electrical separation 60Vdc Remote Shutdown protective electrical separation 60Vdc Analogue Interface see table protective electrical separation 60Vdc working impedance 500Ω Pmax average 1000W continuous and ca 1059 1118W bower boost for max 60s see Power Boost above Derating 60 C 70 C 2 5 C Acc...

Page 4: ...31 3 1 60 6 0 Output Capacity mF typ 8 56 8 56 1 52 0 54 0 23 0 23 Interface Latency 15ms including signal latency for 0 Umax programming Analog Interface Pin Name Type Function Signal Remarks 1 Ureg Input Voltage Programming 0 10Vdc 20mA 0 20mA multi functional interface 500 Ω working resistance with voltage programming 2 Ureg Input 3 Sense Input Sense Control none Compensation max 2V per load li...

Page 5: ...the power supply controls the DC power directly to the DC output terminals In case of an error the OVP acts automatically see OVP values corresponding technical table page 3 The sense terminals are directly connected to the power outputs Remote Sensing Schematics Although the HSEUREG sense block is more simple it applies to the below schematics Please note that the HSEUREG has no AUX connection fe...

Page 6: ...ve 60Vdc If the units are remotely controlled via the analog interface it is compulsory to use a potential free control voltage Parallel Operation N 1 Decoupling In order to increase the overall power of the power supply two or more devices of the same model with the same output voltage may be operated in parallel We recommend using a busbar for the DC power connector Make sure that the cable leng...

Page 7: ...eld test owner test follow the below instruction a Use suitable test equipment raising the voltage slowly b Short circuit L1 and N and all the DC output terminals c Use only test voltages of 50 60Hz The outputs are unearthed and therefore they have no resistance to GND PE d If the residual voltage is 60Vdc observe the safety standards Use only specially insulated screwdriver to trim the Ua Ia Term...

Page 8: ...m your retailer Safety regulations Please read these instructions completely before using the equipment Keep these instructions on to hand The device may only be operated by trained specialist staff Installation 1 The device is designed for devices and systems that meet the standard requirements for hazardous voltages power and fire prevention 2 Installation and service only by trained persons The...