CSIOPCServer

User’s Manual and

Installation Guide

Revision: 10/09

C o p y r i g h t   ©   2 0 0 1 - 2 0 0 9

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for CSIOPC

Page 1: ...CSIOPCServer User s Manual and Installation Guide Revision 10 09 C o p y r i g h t 2 0 0 1 2 0 0 9 C a m p b e l l S c i e n t i f i c I n c...

Page 2: ......

Page 3: ...copy of the software is an upgrade from a previous version you must possess a valid license for the earlier version of software You may continue to use the earlier copy of software only if the upgrad...

Page 4: ...dia or documentation Campbell Scientific will correct errors without charge by providing new media addenda or substitute pages If Campbell Scientific is unable to replace defective media or documentat...

Page 5: ...CServer 1 2 2 Providing Data to Multiple Computers 2 3 CSI s Hardware and Software in an OPC Application 2 4 Identifying Data Values 4 4 1 Data Tags 4 4 2 CSIOPCServer Browser 5 5 Data Reliability 5 5...

Page 6: ......

Page 7: ...the CSIOPCServer CSIOPCServer was designed to run on a PC based computer system A Windows NT 2000 or XP operating system is suggested though the application will run on Windows 95 98 or ME In addition...

Page 8: ...ts function in a data acquisition and management network The main component of the LoggerNet software is an application known as the LoggerNet communications server All communication with the datalogg...

Page 9: ...server LoggerNet client applications and remote clients Telecommunications Datalogger Network CSIOPCServer Options Direct Connect Phone RF TCP IP MD485 etc LoggerNet s Data Cache OPC Clients s PC Runn...

Page 10: ...network map table_name is the name of the table in the datalogger program and field_name is the name of the variable port or flag for the data value being returned CRBasic dataloggers support variabl...

Page 11: ...does not readily accommodate changes that occur if a new program is downloaded to a datalogger If changes are made to the datalogger program or the LoggerNet device map it may be necessary to shut dow...

Page 12: ...ith the datalogger 6 Technical Notes 6 1 Registering the CSIOPCServer If the CSIOPCServer executable is moved to a different directory or if that directory is renamed it will be necessary to re regist...

Page 13: ...the total number of communications attempts the device made during the ten minute interval This counter is incremented by one for every entry that appears in the communications status log and is asso...

Page 14: ...ing total of the number of communication retry events that have been logged since the device was started or the statistic was last reset 6 3 2 4 Total Failures Type uint4 Applies to all device types D...

Page 15: ...o 21X CR7X CR10 CR10X CR500 CR510 CR23X CR10T CR10X TD CR510T CR23X TD CR9000 CR5000 CR10X PB CR510 PB CR23X PB CR200 Series CR800 CR1000 CR3000 RF95T Description Relates the server time when the cloc...

Page 16: ...when the next polling event will take place for the datalogger for the currently active schedule 6 3 2 13 Last Coll Attempt Type stamp Applies to 21X CR7X CR10 CR10X CR500 CR510 CR23X CR10T CR10X TD C...

Page 17: ...CR5000 CR10X PB CR510 PB CR23X PB CR205 CR210 CR215 CR1000 Description The number of scalar values that have been collected from the datalogger since the last poll began 6 3 2 16 Vals to Coll Type uin...

Page 18: ...ld devices have gone off line and this device is cleaning up the link so that it can go to an off line state 6 comm disabled Communications are disabled for either this device its parent or for the wh...

Page 19: ...torage values that need to be collected from final storage area two of a classic datalogger if collection is active for that area If collection is not active for that area this statistic reflects the...

Page 20: ...R23X TD CR9000 CR5000 CR10X PB CR510 PB CR23X PB CR205 CR210 CR215 CR1000 Description Reports the number of collection retries that the datalogger device has had since the first collection error occur...

Page 21: ...he datalogger 3 suspect A collection attempt has returned an invalid table definitions code The server needs to verify the table definitions for the logger 4 getting Indicates that the server is curre...

Page 22: ...that is available to the server process 6 3 3 3 Used Virt Mem Type uint4 Description Relates the amount of virtual memory that is being used by the server process This value is derived from the Avail...

Page 23: ......

Page 24: ...a Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller Santo Doming...