background image

 

 

 

 

Manual No. 99104500140, Rev. C 

 

CLIF MOCK 

 

CMC-500  

 

Circulating System 

 

 

User Manual 

Summary of Contents for CMC-500

Page 1: ...Manual No 99104500140 Rev C CLIF MOCK CMC 500 Circulating System User Manual ...

Page 2: ......

Page 3: ... confidential and proprietary property of Cameron Any reproduction or use of these instructions drawings or photographs without the express written permission of an officer of Cameron is forbidden All Rights Reserved Printed in the United States of America Manual No 99104500140 Rev C December 2006 ...

Page 4: ......

Page 5: ...CMC 500 Circulating System i December 2006 Table of Contents Description 1 Installation 1 Startup Procedures 1 Operation 2 CMC 500 Circulating System Bill of Materials 3 ...

Page 6: ...December 2006 ii CMC 500 Circulating System ...

Page 7: ...onnections slope downward from the sampling device into the receptacle 3 Connect the drain valve to a sump or back into the pipeline NOTE Pipeline pressure must be less than 100 psi when returning collected sample back into the pipeline 4 Install the ON OFF Switch supplied by customer near the CMC 500 Circulating System 5 Check all electrical connections All field wiring must conform to the Nation...

Page 8: ...s thoroughly mixed 2 While the circulating pump is ON open the sample draw off valve item 11 allowing the sample to flow directly into laboratory glassware Close the sample draw off valve item 11 and cap the laboratory sample transport receptacle immediately 3 To drain the tank receptacle perform the following steps a Turn the circulating pump ON b Close the return valve item 15A c Open the drain ...

Page 9: ...lear Plastic Tubing 7 1 50142307905 Sight Glass 5 8 in Dia Heavy Wall 8 2 50142307911 Grommet Sponge 9 2 50142307912 Clamps 10 1 50142381037 0 60 psi Liquid Filled Pressure Gauge 11 1 50142208006 Valve Sample Draw Off 12 1 50142304100 1 2 in Static Mixer SS 13 1 50142302205 Tubing 3 4 in OD SS 14 1 50142302204 Spray Bar Internal SS 15 3 50142303642 Ball Valve 1 2 in 16 1 50142307353 Guard Motor Cp...

Page 10: ...ty and Buyer s exclusive remedy in any case of action whether in contract tort breach of warranty or otherwise arising out of the sale or use of any products software supplies or materials is expressly limited to the replacement of such products software supplies or materials on their return to Seller or at Seller s option to the allowance to the customer of credit for the cost of such items In no...