READ AND SAVE THESE INSTRUCTIONS

Model HUMXXSTM3034 

Residential Steam Humidifier

Owner’s Manual

Includes Safety & Operating Instructions

Residential

Steam Humidifier

Содержание HUMXXSTM3034

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Model HUMXXSTM3034 Residential Steam Humidifier Owner s Manual Includes Safety Operating Instructions Residential Steam Humidifier ...

Страница 2: ... until electrical power is disconnected Follow the shutdown procedure in this manual before performing service or maintenance procedures on any part of the system Electrical shock hazard If the humidifier starts up responding to a call for humidity during maintenance severe bodily injury or death from electrical shock could occur Follow the procedures in this manual before performing service or ma...

Страница 3: ...m and Canister 90 1522 Steam Outlet Drain Supply Water Drain Cup Drain Valve Canister Electrodes High Water Level Sensor Flow Control Orifice Inlet Fill Valve Overflow Fill Fill Cup Thank you for your recent steam humidifier purchase We appreciate your business and are pleased to add your name to our growing list of customers You have invested in the highest quality equipment available Your humidi...

Страница 4: ...s time the Steam light illuminates green If the humidifier cannot produce steam at the rated level after trying for 168 hours the Steam light illuminates yellow The humidifier continues to operate in this state until the rated output is reached The conductivity of naturally soft water hard water and softened water changes as the water heats up but the internal controller adjusts the water level to...

Страница 5: ...rent level below 75 of the maximum operating current Humidifier continues to operate but at reduced capacity Solid Red Operational problem with humidifier Humidifier shuts down Occurs when unit detects over current which can be caused by failure to drain or other system failures Call your heating and air conditioning dealer for service HUMIDIFIER CONTROL OPERATING INSTRUCTIONS The control provided...

Страница 6: ...obe conductor 5 Loosen hose clamp at top of canister 6 Slide hose off top of canister 7 Slide canister up and out of drain assembly Discard canister 8 Remove o ring from drain assembly using small screw driver 9 Inspect drain assembly and remove any debris See drain valve cleaning procedure in Installation Maintenance manual 10 Insert new o ring into slot in drain assembly O ring is provided with ...

Страница 7: ...Form OG HUMXXSTM 01 10009952 B2205831A 10 12 2012 CAC BDP 7310 West Morris St Indianapolis IN 46231 ...

Отзывы: