background image

Page 1 

Bullfrog Spas Owner’s Manual 

Owner’s  

Manual

 

For all 

2001

 Bullfrog Portable Spas 

  

(Multiple Patents with Other Patents Pending) 

TABLE OF CONTENTS

 

 

IMPORTANT SAFETY INSTRUCTIONS 

U.L. Safety Instructions ........................................ P. 02 

Additional Safety Instructions .............................. P. 03 

 

UPGRADES & ACCESSORIES

 ..................... P. 06 

 

INSTALLATION & SET-UP 

Selecting a Site for your Spa ................................ P. 06 

Electrical Requirements & Hook-Up ..................... P. 08 

Checklist Before Filling Your Spa ......................... P. 11 

Initial Start-Up ....................................................... P. 12

 

 

OPERATION 

Control Systems ................................................... P. 13 

JetPaks .................................................................. P. 23 

Jetting ................................................................... P. 24 

JetZones ................................................................ P.  25 

 

MAINTENANCE

 

Water Chemistry ................................................... P. 26 

pH Sensor Care 

(Limited Control Option Only)

 .............. P. 29 

Changing Your Spa Water .................................... P. 30 

Cleaning Your Filter .............................................. P. 31 

Light Bulb Replacement ........................................ P. 32 

Ozone Sterilizer Replacement .............................. P. 32 

Spa Shell Care ....................................................... P. 33 

Spa Cabinet Care .................................................. P. 33 

Spa Cover Care ..................................................... P. 34 

Miscellaneous Care ............................................... P. 34 

 

LOW-USE OR NO-USE PERIODS

 ............... P. 35 

 

SERVICE

 ............................................................. P. 36 

 

TROUBLESHOOTING GUIDE

 ..................... P.  38 

 

MISCELLANEOUS

 

Parts Identification Diagram ................................ P. 40 

Notes ..................................................................... P. 41 

 

 

(Revised: August 6, 2001) 

Содержание 2001 Portable Spas

Страница 1: ...cklist Before Filling Your Spa P 11 Initial Start Up P 12 OPERATION Control Systems P 13 JetPaks P 23 Jetting P 24 JetZones P 25 MAINTENANCE Water Chemistry P 26 pH Sensor Care Limited Control Option...

Страница 2: ...uction fittings in this spa are sized to match the specific water flow created by the pump Should the need arise to replace the suction fittings or the pump be sure that the flow rates are compatible...

Страница 3: ...of water temperature regulating devices varies d The use of alcohol drugs or medication before or during spa use may lead to unconsciousness with the possibility of drowning e Persons suffering from...

Страница 4: ...anning or Experiencing Pregnancy Please consult your physician if the above applies to you or anyone using your spa 3 WARNING Risk of Children Drowning Although your spa cover is not rated as a safety...

Страница 5: ...pa or Equipment By performing maintenance as described later in this Owner s Manual the chance of damage to your spa and it s equipment will be greatly reduced Never block the air vents that lead to t...

Страница 6: ...e you are using your spa the Cover Lifter neatly stores your cover behind the spa Automatic pH Sensor Save time by having Bullfrog s Automatic pH Sensor test your spa water s pH for you only available...

Страница 7: ...A catch basin equivalent to the volume of your spa is recommended Second it is recommended that the room you install the spa in has proper ventilation Proper ventilation can usually be achieved by an...

Страница 8: ...Portable Spa comes standard as a 240 Volt spa If your spa is equipped with a Standard Control System BULF65 it can be wired as either a dedicated 120V or 240V system With the 120 Volt Standard Contro...

Страница 9: ...al Ground 20 AMP 60HZ Single Phase service to the front left corner when you are facing the control pad of the Bullfrog Portable Spa This service must include a disconnect that is visible from the spa...

Страница 10: ...n the required wires through the conduit and to the Control Center 5 Connect the 3 wires 120V systems 4 wires 240V systems to the terminal block located in the Control Center see appropriate Wiring Di...

Страница 11: ...n Plugs Fig G to prevent the possibility of leakage sometimes these fittings loosen during shipment 4 Check Valve Keepers Verify that a Valve Keeper Fig H is installed on each slice valve Valve keeper...

Страница 12: ...ming mode indicated by Pr on the display The Priming mode will last for less than 5 minutes and then the spa will begin normal operation in Standard Mode For the first one minute F will appear on the...

Страница 13: ...ind the following booklet prepared by the Federal Communications Commission helpful How to identify and resolve radio TV interference problems This booklet is available from the U S Government Printin...

Страница 14: ...ble at the Master Control Pad for 2 4 or 6 hours The default filter time is 4 hours To program press Temp Set then Jets1 Press Temp Set to adjust Press Jets 1 to exit programming Pump 2 purges for 5 m...

Страница 15: ...as the Master Control Pad Fig M Jets 2 Touch the Jets 2 button once to activate the low speed of pump 2 and again for the high speed Press the Jets 2 button again to turn off pump 2 If left running th...

Страница 16: ...pt for auxiliary freeze control Press any panel button to resume spa operation Freeze Protection If the temperature sensors detect a drop to 40 F within the heater then pump 1 and the heater if necess...

Страница 17: ...rary condition If flashing by itself spa is shut down Action Required If the problem persists contact your authorized Bullfrog Portable Spa Dealer HFL on Display Persistent low flow problems Occurs on...

Страница 18: ...ime hasn t been programmed the TIME icon flashes To set the time press Time and follow prompts using the Warm and Cool buttons to adjust time Jets 1 Press the Jets 1 button once to turn pump 1 on or o...

Страница 19: ...ed is current only when the circ pump has been running for at least 2 minutes The STANDARD icon will display until the mode is changed Economy Mode heats the spa to set temperature only during filter...

Страница 20: ...erature is locked To unlock the panel press Warm or Cool then Time and Cool DIAGNOSTIC MESSAGES No Message on Display Power has been cut off to the spa Action Required The control panel will be disabl...

Страница 21: ...dicate a flow problem Action Required Check water level in spa Refill if necessary If the water level is okay make sure the pumps have been primed If problem persists contact your authorized Bullfrog...

Страница 22: ...ce STANDBY MODE on Display Standby Mode has been activated by pressing a button combination on user panel Action Required Press any button to leave Standby Mode and return operation PH LOW RAISE PH on...

Страница 23: ...l prevent the pump s from activating while interchanging JetPaks See Standby Mode under OPERATION in this Manual 2 Remove the headrest 3 Using your hands remove the SnapCap top mounting plate by lifti...

Страница 24: ...ts allow for after market interchangeable jet nozzles Always contact your authorized Bullfrog Portable Spa Dealer before attempting to add jets or pump horsepower to your spa ADJUSTABLE JETS Fig S To...

Страница 25: ...in Standby Mode This will prevent the pump s from activating while disconnecting JetPaks See Standby Mode under OPERATION in this Manual 2 Locate the JetPak that contains the JetZone Divider 3 Remove...

Страница 26: ...p the water clean Effective and safe sanitizers include any of the following GRANULAR CHLORINE Dichlor GRANULAR BROMINE CHLORINE TABLETS TriChlor OR BROMINE TABLETS Note Non trichlor chlorine tablets...

Страница 27: ...CALCIUM HARDNESS INCREASER High CH hard water can cause cloudy water as well as rough scale build up on the spa s surface and equipment To correct or manage high CH contact your authorized Bullfrog P...

Страница 28: ...tizer level is below 1 0 Start up water chemistry is now complete However it may take several days for the filter to completely clear the water MAINTAINING SPA WATER Sanitizer and pH Levels It is impo...

Страница 29: ...TING Prior to each spa use check the spa water If the water appears cloudy or off color has significant surface foam or smells of chlorine bromine then there is a problem with the water and it needs t...

Страница 30: ...the sanitizer level bromine or chlorine level of your spa water is less than 5 PPM 4 Clean the spa shell refer to Spa Shell Care in this Owner s Manual Steps To Refill Your Spa 1 Remove garden hose fr...

Страница 31: ...while cleaning the cartridge See Standby Mode under OPERATION in this Owner s Manual 2 Remove skimmer face plate and basket 3 Grasp cartridge s and lift out With a garden hose and nozzle or other high...

Страница 32: ...d only during a preprogrammed filter cycle making sure that the indicator light glows do not check the indicator light if you have activated the jets within the previous 30 minutes as a safety device...

Страница 33: ...llfrog Portable Spa Dealer for acceptable cleaning agents To remove light scratches and or to protect your spa s shell see your Bullfrog Dealer for an acceptable spa wax Note 1 Never allow your spa su...

Страница 34: ...allons of water Scrub the cover using a gentle circular motion being careful not to let any areas of the cover dry before rinsing with water 4 Rinse the cover thoroughly and then dry with a clean clot...

Страница 35: ...to not use your spa for one two weeks then we suggest that you not make any changes in operating your spa Substantially reducing the water temperature in well insulated spas for short periods of time...

Страница 36: ...Trouble Shooting Guide please contact your authorized Bullfrog Portable Spa Dealer WARRANTY SERVICE If your Bullfrog Portable Spa fails within the warranty period and within the scope of its warranty...

Страница 37: ...__________________________________ DATE YOU PURCHASED YOUR SPA Dealer Information ____________________________________________________ Dealer Name ____________________________________________________...

Страница 38: ...frog Portable Spa Dealer PROBLEM Spa will not heat Cause 1 Slice Valve is partially or fully closed Solution Open Slice Valve and secure with Valve Keeper Cause 2 Thermostat on Control Pad has been tu...

Страница 39: ...is not installed This only applies to spas that have two pumps Solution Re install in the appropriate JetPak position Warning Running your spa without a JetZone Divider can cause serious damage to you...

Страница 40: ...et Floor Drain Auxiliary Control Pad Destiny Series only Water Level Indicator Mark Skimmer Skimmer Basket Filter Thermostat Sensor Lights Master Control Pad Equipment Compartment Drain Hose inside Pr...

Страница 41: ...Page 41 Bullfrog Spas Owner s Manual NOTES...

Страница 42: ...Page 42 Bullfrog Spas Owner s Manual Bullfrog International L C 9479 South 500 West Sandy Utah 84070 801 565 8111 Fax 801 565 8333 www bullfrogspas com E mail info bullfrogspas com...

Отзывы: