background image

 

Form No. PDS CM5A.24.2

 

CM5A/CM5B COILS

KMABA  BLOWERS

 

For Manufactured Homes

 

4THE CM5A/CM5B INDOOR COIL

 

To complete your cooling or heating system, the model CM5A
or CM5B Coil is installed inside your Evcon/Coleman, Nor-
dyne/Miller/Intertherm or AirPro gas or electric downflow fur-
nace. Both coils are uncased, and designed for installation
within the manufactured home furnace casing or inside a fac-
tory-installed plenum. These indoor coils are designed to be
used in conjunction with blower kits and other accessories.
The CM5A and CM5B coils are designed for quick and easy in-
stallation by a qualified service technician.

The CM5A comes with factory-installed mechanical connec-
tions. The CM5B comes with factory-installed sweat connec-
tions. Both coils utilize a Check-Flo-Rater® piston for refrig-
erant flow control. Both coils can be used in cooling-only
applications or as part of a heat pump system.

When heating in conjunction with a heat pump, the outdoor
heat pump unit recovers heat from the outdoor air, and trans-
mits it to the CM5A or the CM5B indoor coil for distribution to
the living space. The CM5A and CM5B coils are not activated
when heating in conjunction with a furnace without a heat
pump in the system.

Built-in drainage assembly ensures leak-free condensate re-
moval. Periodic cleaning of filter and drainage sections is rec-
ommended to avoid possible sediment blockage. The A-shape
design of the coil provides maximum cooling-heating transfer
surface and ease of handling at installation. Four coil sizes are
available from 024 though 048, covering a wide range of cool-
ing-heating capacities to meet varying manufactured home re-
quirements.

 

THE KMABA BLOWER

 

KMABA Blower Kits and Accessories are designed and built to
meet the needs of the manufactured housing market. The kits
are used to upgrade Nordyne and Evcon gas and electric fur-
naces (see note). For cooling and heat pump duty, kits avail-
able include blowers for up to 4 tons of air conditioning, control
boxes, insulation kits, filter kits, and evaporator coil shelves.

Blower kits for gas furnaces are shipped without controls. Order
the control box from accessory usage chart. Blower kits for elec-
tric furnaces are shipped with or without controls. See acces-
sory usage chart for details. All control box kits are designed to
operate with a minimum 4-wire thermostat.

Quick connect wire harnesses are shipped with the appro-
priate blower kit or control box for ease of installation. Sheet
metal adapter plates also are included with the blower kits that
are needed to adapt the blower with the furnace.

NOTE: Intertherm, Miller, Coleman, and AirPro brands.

 

Summary of Contents for CM5A

Page 1: ...the system Built in drainage assembly ensures leak free condensate re moval Periodic cleaning of filter and drainage sections is rec ommended to avoid possible sediment blockage The A shape design of the coil provides maximum cooling heating transfer surface and ease of handling at installation Four coil sizes are available from 024 though 048 covering a wide range of cool ing heating capacities t...

Page 2: ...RIES 024 A 036 A 042 A 048 A Operating Weight Lb 21 23 26 28 REFRIGERANT Control Check Flo Rater Piston COIL Type Uncased A Type with Aluminum Fins Rows Fins In 3 15 3 15 3 15 4 13 Face Area Sq Ft 3 11 3 56 4 00 3 56 Nominal CFM 800 1200 1200 1200 CONNECTIONS Type Mechanical Vapor In ID 5 8 3 4 Liquid In ID 3 8 OPTIONAL EQUIPMENT TXV Hard Shutoff KSATX0801HSO KSATX0901HSO FRONT RIGHT SIDE A 7 8 OD...

Page 3: ...ERIES 024 A 036 A 042 A 048 A Operating Weight Lb 21 23 26 28 REFRIGERANT Control Check Flo Rater Piston COIL Type Uncased A Type with Aluminum Fins Rows Fins In 3 15 3 15 3 15 4 13 Face Area Sq Ft 3 11 3 56 4 00 3 56 Nominal CFM 800 1200 1200 1200 CONNECTIONS Type Sweat Vapor In ID 5 8 3 4 7 8 Liquid In ID 3 8 OPTIONAL EQUIPMENT TXV Hard Shutoff KSATX0801HSO KSATX0901HSO FRONT RIGHT SIDE A 7 8 OD...

Page 4: ...s Phase 115 1 115 1 208 230 1 208 230 1 208 230 1 208 230 1 Operating Voltage Range 104 127 104 127 187 253 187 253 187 253 187 253 Full Load Amps 7 20 9 00 3 00 4 30 3 00 4 30 BLOWER MOTOR Motor Hp PSC 1 2 1 2 1 2 3 4 1 2 3 4 RPM Speeds 1075 3 Blower Type Direct Drive BLOWER WHEEL Diameter In 10 1 2 11 1 2 10 1 2 11 1 2 10 1 2 11 1 2 Width In 8 Air Discharge Downflow Maximum Cooling Capacity 3 To...

Page 5: ... 46 7 0 11 46 9 42 5 0 12 37 4 37 1 0 16 31 5 31 5 0 29 CM5A CM5B042 1000 72 77 4 36 7 0 00 71 5 33 8 0 00 64 7 30 7 0 00 56 8 27 4 0 11 47 8 23 8 0 08 67 65 2 39 2 0 09 59 0 36 1 0 08 51 6 32 7 0 07 43 3 29 0 0 06 33 6 25 0 0 07 62 54 2 41 6 0 07 47 4 38 1 0 07 39 9 34 4 0 07 31 2 29 9 0 09 25 5 25 5 0 21 1200 72 85 9 40 6 0 00 79 8 37 7 0 00 72 1 34 4 0 20 63 3 30 7 0 11 53 6 27 0 0 10 67 72 8 4...

Page 6: ... 0 09 0 14 0 12 0 19 0 15 0 23 0 19 0 27 0 22 036 WET DRY 1000 1100 1200 1300 1400 0 22 0 19 0 28 0 23 0 32 0 27 0 37 0 31 0 42 0 36 042 WET DRY 1100 1200 1300 1400 1500 0 24 0 20 0 28 0 24 0 32 0 29 0 38 0 33 0 43 0 39 048 WET DRY 1200 1300 1400 1500 1600 0 30 0 27 0 35 0 29 0 40 0 33 0 45 0 38 0 51 0 43 ...

Page 7: ...t ACCESSORY KIT NO USED WITH Evcon Coleman AirPro Nordyne Miller Intertherm Gas Furnaces Electric Furnaces Gas Furnaces Electric Furnaces DGRT A 7900 DGRT B DGAT 3400 3400A 3500A8 EB B MGHA MGBA MGBB MGHB E1EB E1EH FEBA FEBB FEH2 FEHB BLOWER PACKAGES KMABA01013TG X X X X KMABA02014TG X X X X X X KMABA03013TE X KMABA04014TE X KMABA05013TE X X X KMABA06014TE X X X CONTROL BOXES KMACC02014WG X X X KM...

Page 8: ...sed in this manual including Unit Familiarization Maintenance Installation Overview Operating Sequence A large selection of product theory and skills programs is available using popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that really pays dividends in fa...

Reviews: